6 research outputs found

    A comparative study of input devices for digital slide navigation

    No full text
    Quick and seamless integration between input devices and the navigation of digital slides remains a key barrier for many pathologists to "go digital." To better understand this integration, three different input device implementations were compared in terms of time to diagnose, perceived workload and users\u27 preferences. Six pathologists reviewed in total nine cases with a computer mouse, a 6 degrees-of-freedom (6DOF) navigator and a touchpad. The participants perceived significantly less workload (

    Implementation of large‑scale routine diagnostics using whole slide imaging in Sweden: Digital pathology experiences 2006-2013

    Get PDF
    Recent technological advances have improved the whole slide imaging (WSI) scanner quality and reduced the cost of storage, thereby enabling the deployment of digital pathology for routine diagnostics. In this paper we present the experiences from two Swedish sites having deployed routine large-scale WSI for primary review. At Kalmar County Hospital, the digitization process started in 2006 to reduce the time spent at the microscope in order to improve the ergonomics. Since 2008, more than 500,000 glass slides have been scanned in the routine operations of Kalmar and the neighboring Link\uf6ping University Hospital. All glass slides are digitally scanned yet they are also physically delivered to the consulting pathologist who can choose to review the slides on screen, in the microscope, or both. The digital operations include regular remote case reporting by a few hospital pathologists, as well as around 150 cases per week where primary review is outsourced to a private clinic. To investigate how the pathologists choose to use the digital slides, a web-based questionnaire was designed and sent out to the pathologists in Kalmar and Link\uf6ping. The responses showed that almost all pathologists think that ergonomics have improved and that image quality was sufficient for most histopathologic diagnostic work. 38 \ub1 28% of the cases were diagnosed digitally, but the survey also revealed that the pathologists commonly switch back and forth between digital and conventional microscopy within the same case. The fact that two full-scale digital systems have been implemented and that a large portion of the primary reporting is voluntarily performed digitally shows that large-scale digitization is possible today

    Towards grading gleason score using generically trained deep convolutional neural networks

    No full text
    \ua9 2016 IEEE.We developed an automatic algorithm with the purpose to assist pathologists to report Gleason score on malignant prostatic adenocarcinoma specimen. In order to detect and classify the cancerous tissue, a deep convolutional neural network that had been pre-trained on a large set of photographic images was used. A specific aim was to support intuitive interaction with the result, to let pathologists adjust and correct the output. Therefore, we have designed an algorithm that makes a spatial classification of the whole slide into the same growth patterns as pathologists do. The 22-layer network was cut at an earlier layer and the output from that layer was used to train both a random forest classifier and a support vector machines classifier. At a specific layer a small patch of the image was used to calculate a feature vector and an image is represented by a number of those vectors. We have classified both the individual patches and the entire images. The classification results were compared for different scales of the images and feature vectors from two different layers from the network. Testing was made on a dataset consisting of 213 images, all containing a single class, benign tissue or Gleason score 35. Using 10-fold cross validation the accuracy per patch was 81 %. For whole images, the accuracy was increased to 89 %

    Understanding Design for Automated Image Analysis in Digital Pathology

    No full text
    Digital pathology is an emerging healthcare field taking advantage of technology that allows digitization of microscopy images. Such digitization enables the use of automated digital image analysis techniques, which could be beneficial for the diagnostic review and prognosis of a variety of conditions. As yet, human-computer interaction (HCI) issues in this field, which is mostly based on visual analysis, have not been systematically explored. Based on reflecting on the process of designing and deploying systems for digital pathology, we propose a new understanding to design automated tools for such environments. We used meeting minutes, design briefs, interviews, personal notes and other artifacts to conduct a thematic analysis. This enabled us to establish four design considerations for introducing digital image analysis to routine pathology that concern level of detail, verification, communication and transparency

    Feature-enhancing zoom to facilitate Ki-67 hot spot detection

    No full text
    Image processing algorithms in pathology commonly include automated decision points such as classifications. While this enables efficient automation, there is also a risk that errors are induced. A different paradigm is to use image processing for enhancements without introducing explicit classifications. Such enhancements can help pathologists to increase efficiency without sacrificing accuracy. In our work, this paradigm has been applied to Ki-67 hot spot detection. Ki-67 scoring is a routine analysis to quantify the proliferation rate of tumor cells. Cell counting in the hot spot, the region of highest concentration of positive tumor cells, is a method increasingly used in clinical routine. An obstacle for this method is that while hot spot selection is a task suitable for low magnification, high magnification is needed to discern positive nuclei, thus the pathologist must perform many zooming operations. We propose to address this issue by an image processing method that increases the visibility of the positive nuclei at low magnification levels. This tool displays the modified version at low magnification, while gradually blending into the original image at high magnification. The tool was evaluated in a feasibility study with four pathologists targeting routine clinical use. In a task to compare hot spot concentrations, the average accuracy was 75\ub14.1% using the tool and 69\ub14.6% without it (n=4). Feedback on the system, gathered from an observer study, indicate that the pathologists found the tool useful and fitting in their existing diagnostic process. The pathologists judged the tool to be feasible for implementation in clinical routine

    Scale Stain: Multi-Resolution Feature Enhancement in Pathology Visualization

    No full text
    Digital whole-slide images of pathological tissue samples have recently become feasible for use within routine diagnostic practice. These gigapixel sized images enable pathologists to perform reviews using computer workstations instead of microscopes. Existing workstations visualize scanned images by providing a zoomable image space that reproduces the capabilities of the microscope. This paper presents a novel visualization approach that enables filtering of the scale-space according to color preference. The visualization method reveals diagnostically important patterns that are otherwise not visible. The paper demonstrates how thisapproach has been implemented into a fully functional prototype that lets the user navigate the visualization parameter space in real time. The prototype was evaluated for two common clinical tasks with eight pathologists in a within-subjects study. The data reveal thattask efficiency increased by 15% using the prototype, with maintained accuracy. By analyzing behavioral strategies, it was possible to conclude that efficiency gain was caused by a reduction of the panning needed to perform systematic search of the images. The prototype system was well received by the pathologists who did not detect any risks that would hinder use in clinical routine
    corecore