1,239 research outputs found

    Hyperspectral Imaging for Burn Depth Assessment in an Animal Model

    Get PDF
    Differentiating between superficial and deep-dermal (DD) burns remains challenging. Superficial-dermal burns heal with conservative treatment; DD burns often require excision and skin grafting. Decision of surgical treatment is often delayed until burn depth is definitively identified. This study\u27s aim is to assess the ability of hyperspectral imaging (HSI) to differentiate burn depth. METHODS: Thermal injury of graded severity was generated on the dorsum of hairless mice with a heated brass rod. Perfusion and oxygenation parameters of injured skin were measured with HSI, a noninvasive method of diffuse reflectance spectroscopy, at 2 minutes, 1, 24, 48 and 72 hours after wounding. Burn depth was measured histologically in 12 mice from each burn group (n = 72) at 72 hours. RESULTS: Three levels of burn depth were verified histologically: intermediate-dermal (ID), DD, and full-thickness. At 24 hours post injury, total hemoglobin (tHb) increased by 67% and 16% in ID and DD burns, respectively. In contrast, tHb decreased to 36% of its original levels in full-thickness burns. Differences in deoxygenated and tHb among all groups were significant (P \u3c 0.001) at 24 hours post injury. CONCLUSIONS: HSI was able to differentiate among 3 discrete levels of burn injury. This is likely because of its correlation with skin perfusion: superficial burn injury causes an inflammatory response and increased perfusion to the burn site, whereas deeper burns destroy the dermal microvasculature and a decrease in perfusion follows. This study supports further investigation of HSI in early burn depth assessment

    Past, Present, and Future of Multisensory Wearable Technology to Monitor Sleep and Circadian Rhythms.

    Get PDF
    Movement-based sleep-wake detection devices (i.e., actigraphy devices) were first developed in the early 1970s and have repeatedly been validated against polysomnography, which is considered the "gold-standard" of sleep measurement. Indeed, they have become important tools for objectively inferring sleep in free-living conditions. Standard actigraphy devices are rooted in accelerometry to measure movement and make predictions, via scoring algorithms, as to whether the wearer is in a state of wakefulness or sleep. Two important developments have become incorporated in newer devices. First, additional sensors, including measures of heart rate and heart rate variability and higher resolution movement sensing through triaxial accelerometers, have been introduced to improve upon traditional, movement-based scoring algorithms. Second, these devices have transcended scientific utility and are now being manufactured and distributed to the general public. This review will provide an overview of: (1) the history of actigraphic sleep measurement, (2) the physiological underpinnings of heart rate and heart rate variability measurement in wearables, (3) the refinement and validation of both standard actigraphy and newer, multisensory devices for real-world sleep-wake detection, (4) the practical applications of actigraphy, (5) important limitations of actigraphic measurement, and lastly (6) future directions within the field

    Perfusion Changes by Hyperspectral Imaging in a Burn Model

    Get PDF
    BACKGROUND: Early excision and skin grafting of full-thickness and deep-dermal burns is therapeutically advantageous. However, while full-thickness burns are clinically evident, differentiating between superficial versus deep partial-thickness burns presents a diagnostic challenge, with only 50-75% accuracy. Superficial-dermal burns heal, while deep-dermal burns often require excision and skin grafting. Decision of surgical treatment is often delayed until burn depth is definitively identified. This study’s aim is to establish a thermal burn model in mice in order to assess the ability of Hyperspectral Imaging (HSI) in differentiating burn depth. METHODS: Burns of graded severity were generated on the dorsum of seventy-six hairless mice with a brass rod heated to 50, 60, 70, 80, or 90°C. Perfusion and oxygenation parameters of the injured skin were measured with HSI, a non-invasive method of wide-field, diffuse reflectance spectroscopy at 2 minutes, 1 hour, 24 hours, 48 hours, and 72 hours after wounding. Burn depth was measured histologically (n=44) at 72 hours post injury using Masson’s trichrome staining. RESULTS: Three discrete levels of burn depth were verified histologically, as follows in order of increasing depth: intermediate-dermal, deep-dermal, and full-thickness injury. At 24 hours post injury, total hemoglobin increased by 67% and 18% in intermediate and deep dermal burns, respectively. In contrast, total hemoglobin decreased by 64% in full-thickness burns. Differences in deoxygenated hemoglobin, total hemoglobin, and oxygen saturation for all group comparisons were statistically significant (p CONCLUSION: HSI was able to differentiate among three discrete levels of burn injury. This is likely due to its correlation with skin perfusion: superficial burn injury causes an inflammatory response and increased perfusion to the burn site, while deeper burns destroy the dermal microvasculature and a decrease in perfusion follows. This study supports further investigation in the use of HSI in early burn depth assessment

    The FC-1D: The profitable alternative Flying Circus Commercial Aviation Group

    Get PDF
    The FC-1D was designed as an advanced solution for a low cost commercial transport meeting or exceeding all of the 1993/1994 AIAA/Lockheed request for proposal requirements. The driving philosophy behind the design of the FC-1D was the reduction of airline direct operating costs. Every effort was made during the design process to have the customer in mind. The Flying Circus Commercial Aviation Group targeted reductions in drag, fuel consumption, manufacturing costs, and maintenance costs. Flying Circus emphasized cost reduction throughout the entire design program. Drag reduction was achieved by implementation of the aft nacelle wing configuration to reduce cruise drag and increase cruise speeds. To reduce induced drag, rather than increasing the wing span of the FC-1D, spiroids were included in the efficient wing design. Profile and friction drag are reduced by using riblets in place of paint around the fuselage and empennage of the FC-1D. Choosing a single aisle configuration enabled the Flying Circus to optimize the fuselage diameter. Thus, reducing fuselage drag while gaining high structural efficiency. To further reduce fuel consumption a weight reduction program was conducted through the use of composite materials. An additional quality of the FC-1D is its design for low cost manufacturing and assembly. As a result of this design attribute, the FC-1D will have fewer parts which reduces weight as well as maintenance and assembly costs. The FC-1D is affordable and effective, the apex of commercial transport design

    Translational Model for External Volume Expansion in Irradiated Skin

    Get PDF
    Introduction: External Volume Expansion (EVE) treatment has gained popularity in breast reconstruction, enriching recipient sites for fat grafting. For patients receiving radiotherapy (XRT), results of EVE use vary, partly because the effects of EVE on irradiated tissue are not well understood. Based on our previous work with EVE and XRT, we developed a new translational model to investigate the effects of EVE in the setting of chronic radiation skin injury. Methods: Twenty-Eight SKH1-E mice received 50Gy of beta-radiation to each flank. Animals were monitored until chronic radiation fibrosis developed (8 weeks). EVE was then applied to one side for 6hrs on 5 consecutive days. The opposite side served as control. Hyperspectral Imaging (HSI) was used to assess perfusion changes before and after EVE. Mice were sacrificed at 5 days (n=14) and 15 days (n=14) after last application for histological analysis. Tissue samples were stained for vascularity (CD31) and collagen composition (Picro-Sirius red). Results: All animals developed skin fibrosis 8 weeks post-radiation, and changes in perfusion verified skin damage. EVE application induced edema on treated sides. Five days post-application, both sides were hypo-perfused as seen by HSI; with the EVE side 13% more ischemic than the untreated side (p\u3c0.001). Perfusion returned to control side levels by day 15. Blood vessels increased 20% by day 5 in EVE versus control. Collagen composition showed no difference in scar index analysis. Conclusion: EVE temporarily augments radiation-induced hypo-perfusion, likely due to transient edema. Fibrosis remained unchanged after EVE, possibly accounting for the limited expansion seen in patients. It appears that EVE induces angiogenic effect but does not affect dermal collagen composition. Future efforts should focus on reducing fibrosis post radiation to allow EVE to achieve its full potential, to benefit irradiated patients

    To be or not to be: the importance of attendance in integrated physiology teaching using non-traditional approaches

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is increasing use of non-traditional methods like problem-based learning, team-working and several other active-learning techniques in Physiology teaching. While several studies have investigated the impact of class attendance on the academic performance in traditional teaching, there is limited information regarding whether the new modalities are especially sensible to this factor.</p> <p>Methods</p> <p>Here, we performed a comparative study between a control group receiving information through traditional methods and an experimental group submitted to new methodologies in Physiology teaching.</p> <p>Results</p> <p>We found that while mean examination scores were similar in the control and the experimental groups, a different picture emerge when data are organized according to four categorical attendance levels. In the experimental group, scores were not different between the 1st and the 2nd exams (P = 0.429) nor between the 2nd and the 3<sup>rd </sup>exams (P = 0.225) for students that never or poorly attend classes, in contrast to the control group (P < 0.001). A score difference between attending students versus the absentees was maximal in the experimental versus the control group all along the different exams and in the final score.</p> <p>Conclusion</p> <p>We suggest that class attendance is critical for learning using non-traditional methods.</p

    The Gaseous Electronics Conference radio‐frequency reference cell: A defined parallel‐plate radio‐frequency system for experimental and theoretical studies of plasma‐processing discharges

    Full text link
    A ‘‘reference cell’’ for generating radio‐frequency (rf) glow discharges in gases at a frequency of 13.56 MHz is described. The reference cell provides an experimental platform for comparing plasma measurements carried out in a common reactor geometry by different experimental groups, thereby enhancing the transfer of knowledge and insight gained in rf discharge studies. The results of performing ostensibly identical measurements on six of these cells in five different laboratories are analyzed and discussed. Measurements were made of plasma voltage and current characteristics for discharges in pure argon at specified values of applied voltages, gas pressures, and gas flow rates. Data are presented on relevant electrical quantities derived from Fourier analysis of the voltage and current wave forms. Amplitudes, phase shifts, self‐bias voltages, and power dissipation were measured. Each of the cells was characterized in terms of its measured internal reactive components. Comparing results from different cells provides an indication of the degree of precision needed to define the electrical configuration and operating parameters in order to achieve identical performance at various laboratories. The results show, for example, that the external circuit, including the reactive components of the rf power source, can significantly influence the discharge. Results obtained in reference cells with identical rf power sources demonstrate that considerable progress has been made in developing a phenomenological understanding of the conditions needed to obtain reproducible discharge conditions in independent reference cells.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/70394/2/RSINAK-65-1-140-1.pd

    The DEAD-box RNA Helicase DDX6 is Required for Efficient Encapsidation of a Retroviral Genome

    Get PDF
    Viruses have to encapsidate their own genomes during the assembly process. For most RNA viruses, there are sequences within the viral RNA and virion proteins needed for high efficiency of genome encapsidation. However, the roles of host proteins in this process are not understood. Here we find that the cellular DEAD-box RNA helicase DDX6 is required for efficient genome packaging of foamy virus, a spumaretrovirus. After infection, a significant amount of DDX6, normally concentrated in P bodies and stress granules, re-localizes to the pericentriolar site where viral RNAs and Gag capsid proteins are concentrated and capsids are assembled. Knockdown of DDX6 by siRNA leads to a decreased level of viral nucleic acids in extracellular particles, although viral protein expression, capsid assembly and release, and accumulation of viral RNA and Gag protein at the assembly site are little affected. DDX6 does not interact stably with Gag proteins nor is it incorporated into particles. However, we find that the ATPase/helicase motif of DDX6 is essential for viral replication. This suggests that the ATP hydrolysis and/or the RNA unwinding activities of DDX6 function in moderating the viral RNA conformation and/or viral RNA-Gag ribonucleoprotein complex in a transient manner to facilitate incorporation of the viral RNA into particles. These results reveal a unique role for a highly conserved cellular protein of RNA metabolism in specifically re-locating to the site of viral assembly for its function as a catalyst in retroviral RNA packaging
    corecore