28 research outputs found
A randomized controlled trial of PEEK versus titanium interference screws for anterior cruciate ligament reconstruction with 2-year follow-up
Purpose: To compare the clinical performance of ACL reconstruction with PEEK and titanium interference screws at 2 years and to evaluate a novel method of measuring tunnel volume.
Study Design: Randomized controlled trial; Level of evidence, 1.
Methods: A total of 133 patients underwent arthroscopic ACL reconstruction with 4-strand hamstring autografts and were randomized to have titanium or PEEK interference screws for femoral and tibial tunnel fixation. At 2 years, subjective Lysholm and International Knee Documentation Committee scores were assessed and clinical examination performed. At 12 months, MRI was performed to assess graft incorporation and cyst formation, and a novel technique was employed to measure tunnel volumes.
Results: There were no significant differences in graft rerupture rate, contralateral ACL rupture rate, subjective outcomes, or objective outcomes. In the titanium and PEEK groups, MRI demonstrated high overall rates of graft integration (96%-100% and 90%-93%, respectively) and ligamentization (89% and 84%) and low rates of synovitis (22% and 10%) and cyst formation (0%-18% and 13%-15%). There was a higher proportion of patients with incomplete graft integration within the femoral tunnel in the PEEK group as compared with the titanium group (10% vs 0%, P = .03); however, the authors suggest that metal artifact precluded proper assessment of the graft in the titanium group by MRI. Tunnel volumes also appeared to be equivalent in the 2 groups and were measured with a novel technique that was highly reproducible in the PEEK group secondary to the absence of flare.
Conclusion: Two-year clinical analysis of PEEK interference screws for femoral and tibial fixation of ACL reconstructions showed equivalent clinical performance to titanium interference screws. Given the excellent mechanical characteristics, biological compatibility, and absence of metal artifact on MRI, PEEK has become our material of choice for interference screw fixation in ACL reconstruction
20-year outcomes of anterior cruciate ligament reconstruction with hamstring tendon autograft: The catastrophic effect of age and posterior tibial slope
Background: No well-controlled studies have compared the long-term outcome of anterior cruciate ligament (ACL) reconstruction with hamstring tendon autograft between adolescents and adults. Increased posterior tibial slopes (PTSs) have been reported in the ACL-injured versus controls, but the effect of PTS on the outcome after reconstruction is relatively unexplored.
Purpose: To compare the prospective longitudinal outcome of ‘‘isolated’’ ACL ruptures treated with anatomic endoscopic ACL reconstruction using hamstring tendon autograft over 20 years in adolescent and adult cohorts and to examine factors for repeat ACL injury.
Study Design: Case-control study; Level of evidence, 3.
Methods: A single-surgeon series of 200 consecutive patients undergoing isolated primary ACL reconstruction with hamstring tendon autograft were prospectively studied. Subjects were assessed preoperatively and at 2, 7, 15, and 20 years postoperatively. Outcomes included International Knee Documentation Committee (IKDC) Knee Evaluation, IKDC subjective scores, KT-1000 instrumented laxity testing, and radiological evaluation of degenerative change and medial tibial slope. Twenty-year outcomes were compared between those who underwent surgery at the age of 18 years or younger (adolescent group, n = 39) and those who underwent surgery when older than 18 years (adult group, n = 161).
Results: At 20 years, 179 of 200 subjects were reviewed (89.5%). ACL graft rupture occurred in 37 subjects and contralateral ACL injury in 22 subjects. Of those with intact ACL grafts at 20 years, outcomes were not statistically different between adolescents and adults for the variables of IKDC subjective score (P = .29), return to preinjury activity level (P = .84), current activity level (P = .69), or degree of radiological degenerative change at 20 years (P = .51). The adolescent group had a higher proportion of grade 1 ligamentous laxity testing compared with the adult group (P = .003). Overall, ACL graft survival at 20 years was 86% for adults and 61% for adolescents (hazard ration, 3.3; P = .001). The hazard for ACL graft rupture was increased by 4.8 in adolescent males and 2.5 in adolescent females compared with adults. At 20 years, the ACL survival for adolescents with a PTS of ≥ 12° was 22%. The hazard for ACL graft rupture was increased by 11 in adolescents with a PTS of ≥ 12° (P = .001) compared with adults with a PTS \u3c 12°.
Conclusion: Repeat ACL injury after isolated ACL reconstruction is common, occurring in 1 in 3 over 20 years. In the absence of further injury, isolated ACL reconstruction using this technique was associated with good long-term outcomes with respect to patient-reported outcomes and return to sports, regardless of age. However, mild ligament laxity and ACL graft rupture after ACL reconstruction are significantly more common in adolescents, especially adolescent males, compared with adults. PTS of 12° or more is the strongest predictor of repeat ACL injury, and its negative effect is most pronounced in adolescents
Bioabsorbable versus titanium screws in anterior cruciate ligament reconstruction using hamstring autograft: a prospective, blinded, randomized controlled trial with 5-year follow-up
Background: Longer term studies of bioabsorbable screws for ACL reconstruction are reported, but results are specific to the exact screw material and design. Titanium and PLLA-HA screw outcomes have been compared only to 2 years.
Purpose: The aim of this study was to compare the clinical and radiological outcomes of PLLAHA screw (BS) versus a titanium screw (TS), for hamstring tendon anterior cruciate ligament reconstruction over 5 years. We hypothesized that there are no differences in clinical scores, and tunnel widening, between the BS and the TS groups, and that the PLLA-HA screw as seen on MRI should show high grade resorption and ossification response over 5 years.
Methods: 40 patients undergoing ACLR were randomized to receive either a PLLA-HA screw (BS group) or a Titanium screw (TS group) for ACL fixation. Blinded evaluation was performed at 2 & 5 years with IKDC & Lysholm knee score, KT-1000 arthrometer, single legged hop test, and MRI to evaluate tunnel and screw volumes, peri-screw ossification, graft integration and cyst formation.
Results: There was no difference in any clinical outcome measure at 2 or 5 years between the 2 groups. At 2 years, the BS femoral tunnel was smaller than the TS tunnel (p=0.02) and at 5 years, there was no difference. At 2 years the femoral BS screw was a mean 76% of its original volume and by 5 years, 36%. At 2 years the tibial BS screw mean volume was 68% of its original volume and by 5 years, 46%. At 5 years BS group 88% of femoral tunnels and 56% of tibial tunnels demonstrated a significant ossification response. There was no increase in cyst formation in the BS group and no screw breakages.
Conclusion: Our study has shown equivalent clinical results between BS and TS groups at 2 and 5 years. This PLLA-HA screw was not associated with increased tunnel widening or cyst formation when compared with the titanium screw. The PLLA-HA screw demonstrated progressive screw resorption and gradual, but incomplete ossification over 5 years
Orally Active Multi-Functional Antioxidants Delay Cataract Formation in Streptozotocin (Type 1) Diabetic and Gamma-Irradiated Rats
Age-related cataract is a worldwide health care problem whose progression has been linked to oxidative stress and the accumulation of redox-active metals. Since there is no specific animal model for human age-related cataract, multiple animal models must be used to evaluate potential therapies that may delay and/or prevent cataract formation.Proof of concept studies were conducted to evaluate 4-(5-hydroxypyrimidin-2-yl)-N,N-dimethyl-3,5-dioxopiperazine-1-sulfonamide (compound 4) and 4-(5-hydroxy-4,6-dimethoxypyrimidin-2-yl)-N,N-dimethyl-3,5-dioxopiperazine-1-sulfonamide (compound 8), multi-functional antioxidants that can independently chelate redox metals and quench free radicals, on their ability to delay the progression of diabetic "sugar" cataracts and gamma radiation-induced cataracts. Prior to 15 Gy of whole head irradiation, select groups of Long Evans rats received either diet containing compound 4 or 8, or a single i.p. injection of panthethine, a radioprotective agent. Compared to untreated, irradiated rats, treatment with pantethine, 4 and 8 delayed initial lens changes by 4, 47, and 38 days, respectively, and the average formation of posterior subcapsular opacities by 23, 53 and 58 days, respectively. In the second study, select groups of diabetic Sprague Dawley rats were administered chow containing compounds 4, 8 or the aldose reductase inhibitor AL1576. As anticipated, treatment with AL1576 prevented cataract by inhibiting sorbitol formation in the lens. However, compared to untreated rats, compounds 4 and 8 delayed vacuole formation by 20 days and 12 days, respectively, and cortical cataract formation by 8 and 3 days, respectively, without reducing lenticular sorbitol. Using in vitro lens culture in 30 mM xylose to model diabetic "sugar" cataract formation, western blots confirmed that multi-functional antioxidants reduced endoplasmic reticulum stress.Multi-functional antioxidants delayed cataract formation in two diverse rat models. These studies provide a proof of concept that a general cataract treatment focused on reducing oxidative stress instead of a specific mechanism of cataractogenesis can be developed