28,614 research outputs found
Abundance of moderate-redshift clusters in the Cold + Hot dark matter model
Using a set of \pppm simulation which accurately treats the density
evolution of two components of dark matter, we study the evolution of clusters
in the Cold + Hot dark matter (CHDM) model. The mass function, the velocity
dispersion function and the temperature function of clusters are calculated for
four different epochs of . We also use the simulation data to test
the Press-Schechter expression of the halo abundance as a function of the
velocity dispersion . The model predictions are in good agreement
with the observational data of local cluster abundances (). We also
tentatively compare the model with the Gunn and his collaborators' observation
of rich clusters at and with the x-ray luminous clusters at
of the {\it Einstein} Extended Medium Sensitivity Survey. The
important feature of the model is the rapid formation of clusters in the near
past: the abundances of clusters of \sigma_v\ge 700\kms and of \sigma_v\ge
1200 \kms at are only 1/4 and 1/10 respectively of the present values
(). Ongoing ROSAT and AXAF surveys of distant clusters will provide
sensitive tests to the model. The abundance of clusters at would
also be a good discriminator between the CHDM model and a low-density flat CDM
model both of which show very similar clustering properties at .Comment: 21 pages + 6 figures (uuencoded version of the PS files), Steward
Preprints No. 118
Investigation on thermal-hydraulic performance of outdoor heat exchanger in air sources heat pump
A plethora of findings exists on the decreasing heat transfer performance of ASHP under frosting condition. This study investigates, using field and laboratory experiments, the frosting behavior and heat transfer performance of fin-tube exchangers. Findings from our initial observation revealed the severity of frosting phenomenon during winter in hot summer and cold winter zone of China; for avoiding the lower COP, defrosting period of ASHP was not longer than 60 min. The results showed that the basic tube surface temperature decreases with running time and remains stable after 70 min, and an adverse pressure drop ensued. The findings, thereby suggests a 70 min defrosting period in ASHP. Comparing jH/fH and COP between exchangers revealed an improved performance of plain fin-tube exchanger over that of louver fin-tube exchanger in all the test conditions. Therefore, under frosting condition, plain fin-tube heat exchanger provides a superior thermal-hydraulic performance over louver fin-tube heat exchanger. Findings from this study will help designers and facility managers in taking a more informed decision when selecting heat exchanger types for ASHP
Experimental investigation on thermal comfort model between local thermal sensation and overall thermal sensation
To study the human local and overall thermal sensations, a series of experiments under various conditions were carried out in a climate control chamber. The adopted analysis method considered the effect of the weight coefficient of local average skin temperature and density of the cold receptors’ distribution in different local body areas. The results demonstrated that the thermal sensation of head, chest, back and hands is warmer than overall thermal sensation. The mean thermal sensation votes of those local areas were more densely distributed. In addition, the thermal sensation of arms, tight and calf was colder than the overall thermal sensation, which pronounced that thermal sensation votes were more dispersed. The thermal sensation of chest and back had a strong linear correlation with overall thermal sensation. Considering the actual scope of air-conditioning regulation, the human body was classified into three local parts: a) head, b) upper part of body and c) lower part of body. The prediction model of both the three-part thermal sensation and overall thermal sensation was developed. Weight coefficients were 0.21, 0.60 and 0.19 respectively. The model provides scientist basis for guiding the sage installation place of the personal ventilation system to achieve efficient energy use
- …