    Open surgery in VR: Inguinal hernia repair according to Lichtenstein

    Get PDF
    VREST (Virtual Reality Educational Surgical Tools) is developing a universal and\ud autonomous simulation platform which can be used for training and assessment of\ud medical students and for continuing education of physicians. A workstation\ud consisting of two haptic devices and a 3D vision system is part of the VREST\ud platform. Another part of the platform is a generic software environment in which lessons can be built by the teacher and performed by their students. Using the platform one can see, feel and decide as in reality. With the assessment tool the progress and skills of the students can be supervised. The first lesson build on the VREST platform is an inguinal hernia repair according to Lichtenstein. This is an open surgery procedure. The VREST platform is used prior to the first operating room surgery of the resident. Interactive models and case dependant feedback is used to enlarge the residents’ cognition. This should reduce the training time in the operating room

    Validation of open-surgery VR trainer

    Get PDF
    VREST (Virtual Reality Educational Surgical Tools) is developing a universal and\ud autonomous simulation platform which can be used for training and assessment of\ud medical students and for continuing education of physicians. With the VREST -\ud Virtual Lichtenstein Trainer, simulating the open surgery procedure of the inguinal hernia repair according to Lichtenstein, the validation of the simulator is ongoing. Part of this trajectory is the evaluation of the transfer of training of the virtual incision making. One group of students trained incision making on the VREST platform where the control group did not. In an experiment both groups has to perform several incision tasks on a manikin. The results are not available yet but will be presented at the MMVR14 conference

    Quantification of left ventricular function during cardiac assist

    No full text

    Dynamic Pumping Characteristics of the Hemopump®

    No full text
    While pumping blood with the Hemopump® in sheep, the ability of predicting the instantaneous pump flow from the pressure difference over the pump system and pump parameters was investigated. For rotational speed n between 300 and 475 revolutions per second (rps), maximum pump flow QO(n) at zero pressure difference, internal pump resistance R(n), and inertia parameter Lc were found to be suitable parameters for Hemopump® characterization. The instantaneous pump flow could be estimated with an accuracy of approximately 1.0 [ml/s]. The values of the pump source parameters (± sd) were: (the figures in parentheses represent earlier reported values found while pumping water) Lc was a constant of 21.4 ± 6.4 [Pa·s2/ml] (in water: 10.8). QO(n) is linearly related to rotational speed n according to: QO(n) = Qo(ncen) + CQ(n - ncen), with QO(ncen) = 49.4 ± 4.5 [ml/s] (in water: 60.3), CQ = 142 ± 22.4 [10−3 ml] (in water: 146), and ncen = 387.5 [rps]. R(n) is linearly related to rotational speed n according to: R(n) = R(ncen) + CR(n - ncen), with R(ncen) = 556 ± 124 [Pa·s/ml] (in water: 502) and CR = 1.47 ± 0.83 [Pa·s2/ml] (in water: 1.67)

    Characterization of left ventricle function by analysis of pressure responses to steps in rotational speed of the Hemopump

    No full text
    Optimizing the procedure of weaning the left ventricle from a left ventricular assist device requires the determination of the momentaneous condition of the left ventricle. In sheep, a method was developed to momentaneously quantify the left ventricular condition. The left ventricular pump condition was quantified by the time-varying parameters elastance and resistance. They were determined from perturbations in the left ventricular pressure of two subsequent beats induced by changes in flow of the assist device. The end-diastolic volume of the ventricle was estimated without directly measuring ventricular volume. Maximum elastance and resistance were 201.3 ± 32.7 [Palmi] and 12.3 ± 1.6 [Pa·s/ml], respectively (mean ± SE). The ventricular time constant, defined by the ratio of resistance to elastance, was 84.6 ± 17.1 [ms] (man ± SE). </jats:p