672 research outputs found

    The paradox of ventilator-associated pneumonia prevention measures

    Get PDF
    There is a striking paradox in the literature supporting high-profile measures to reduce ventilator-associated pneumonia (VAP): many studies show significant reductions in VAP rates but almost none show any impact on patients' duration of mechanical ventilation, length of stay in the intensive care unit and hospital, or mortality. The paradox is largely attributable to lack of specificity in the VAP definition. The clinical and microbiological criteria for VAP capture a population of patients with an array of conditions that range from serious to benign. Many of the benign events are manifestations of bacterial colonization superimposed upon pulmonary edema, atelectasis, or other non-infectious processes. VAP prevention measures that work by decreasing bacterial colonization preferentially lower the frequency of these mislabelled, more benign events. In addition, misclassification obscures detection of an impact of prevention measures on bona fide pneumonias. Together, these effects create the possibility of the paradox where a prevention measure may have a large impact on VAP rates but minimal impact on patients' outcomes. The paradox makes changes in VAP rates alone an unreliable measure of whether VAP prevention measures are truly beneficial to patients and behooves us to measure their impact on patient outcomes before advocating their adoption

    Staphylococcus Intermedius Infections: Case Report and Literature Review

    Get PDF
    Staphylococcus intermedius is part of the normal skin and oral flora of dogs. Case reports of human infections are rare, but the true incidence is unknown because the pathogen is frequently misidentified as Staphylococcus aureus. Reported cases range from soft tissue infections to brain abscess. Most reported cases in humans have been related to dog exposure. We report a case of a 73 year old female with S. intermedius surgical wound infection one month following a left elbow total arthroplasty. This is the first reported human case of S. intermedius infection of a mechanical prosthesis. The presumed source of infection was the patient’s dog. The patient was treated with vancomycin, then switched to cefazolin and rifampin once susceptibilities were known. Case reports suggest that patients generally respond well to tailored antibiotics with complete or near-complete recovery. S. intermedius should be included in the differential diagnosis of invasive infection amongst patients with close contact with dogs

    Interrater reliability of surveillance for ventilator-associated events and pneumonia

    Get PDF
    OBJECTIVETo compare interrater reliabilities for ventilator-associated event (VAE) surveillance, traditional ventilator-associated pneumonia (VAP) surveillance, and clinical diagnosis of VAP by intensivists.DESIGNA retrospective study nested within a prospective multicenter quality improvement study.SETTINGIntensive care units (ICUs) within 5 hospitals of the Centers for Disease Control and Prevention Epicenters.PATIENTSPatients who underwent mechanical ventilation.METHODSWe selected 150 charts for review, including all VAEs and traditionally defined VAPs identified during the primary study and randomly selected charts of patients without VAEs or VAPs. Each chart was independently reviewed by 2 research assistants (RAs) for VAEs, 2 hospital infection preventionists (IPs) for traditionally defined VAP, and 2 intensivists for any episodes of pulmonary deterioration. We calculated interrater agreement using κ estimates.RESULTSThe 150 selected episodes spanned 2,500 ventilator days. In total, 93–96 VAEs were identified by RAs; 31–49 VAPs were identified by IPs, and 29–35 VAPs were diagnosed by intensivists. Interrater reliability between RAs for VAEs was high (κ, 0.71; 95% CI, 0.59–0.81). Agreement between IPs using traditional VAP criteria was slight (κ, 0.12; 95% CI, −0.05–0.29). Agreement between intensivists was slight regarding episodes of pulmonary deterioration (κ 0.22; 95% CI, 0.05–0.39) and was fair regarding whether episodes of deterioration were attributable to clinically defined VAP (κ, 0.34; 95% CI, 0.17–0.51). The clinical correlation between VAE surveillance and intensivists’ clinical assessments was poor.CONCLUSIONSProspective surveillance using VAE criteria is more reliable than traditional VAP surveillance and clinical VAP diagnosis; the correlation between VAEs and clinically recognized pulmonary deterioration is poor.Infect Control Hosp Epidemiol 2017;38:172–178</jats:sec
    • …
    corecore