266 research outputs found

    Adolescent Idiopathic Scoliosis. The Role of Low Dose Computed Tomography.

    Get PDF
    Continuous implementation of new operative methods for correction and stabilization of spinal deformities in young patients with AIS demands a detailed morphological analysis of the vertebral column. CT spine according to protocols available in daily clinical practice means high radiation dose to these young individuals. All examinations included in this thesis were performed on a 16-slice CT scanner. Examination of the chest phantom in paper I showed that the radiation dose of the spine (including 15 vertebrae) was 20 times lower than that of routinely used protocols for CT examination of the spine in children (0.38 mSv vs 7.76 mSv). In paper II the radiation dose and the impact of dose reduction on image quality were evaluated in 113 consecutive examinations with low-dose spine CT and compared with that of 127 CTs after trauma and 15 CTs performed according to a previously used ANV-protocol of a limited part of the vertebral column. The effective dose of the low-dose spine CT (0.01 mSv/cm scan length) was 20 times lower than that of the standard CT for trauma (0.20 mSv/cm scan length). The absorbed doses to the breasts, genital organs, and thyroid gland in the low-dose spine CT was 8, 265, and 22 times lower than the corresponding doses in CT for trauma. This significant dose reduction conveyed no impact on image quality with regard to answering the clinical questions at issue for the preoperative CTs and for the postoperative CTs after posterior corrective surgery. In paper III the low-dose CT showed to be a reliable method in the evaluation of screw placement in patients with AIS after posterior scoliosis surgery with titanium implants, using the new grading system for screw misplacement. Our proposed grading system for screw misplacement has shown to be feasible, practical, and easy to perform and is in line with the general agreement about the harmlessness of misplacement with minor pedicle breach. In paper IV the evaluation of the clinical and radiological outcome of 49 patients with AIS operated on with titanium “all-pedicle screw construct” showed an overall misplacement rate of 17 %. No evidence of neurovascular complications was reported. In parity with most of the reports in the literature the lateral- and medial cortical perforation were the most common types of screw misplacement (8 % and 6.1 % respectively)

    The rate of screw misplacement in segmental pedicle screw fixation in adolescent idiopathic scoliosis: The effect of learning and cumulative experience

    Get PDF
    Background and purpose There are no reports in the literature on the influence of learning on the pedicle screw insertion. We studied the effect of learning on the rate of screw misplacement in patients with adolescent idiopathic scoliosis treated with segmental pedicle screw fixation. Method We retrospectively evaluated low-dose spine computed tomography of 116 consecutive patients (aged 16 (12-24) years, 94 females) who were operated during 4 periods over 2005-2009 (group 1: patients operated autumn 2005-2006; group 2: 2007; group 3: 2008; and group 4: 2009). 5 types of misplacement were recorded: medial cortical perforation, lateral cortical perforation, anterior cortical perforation of the vertebral body, endplate perforation, and perforation of the neural foramen. Reslts 2,201 pedicle screws were evaluated, with an average of 19 screws per patient. The rate of screw misplacement for the whole study was 14%. The rate of lateral and medial cortical perforation was 7% and 5%. There was an inverse correlation between the occurrence of misplacement and the patient number, i.e. the date of operation (r = -0.35; p < 0.001). The skillfulness of screw insertion improved with reduction of the rate of screw misplacement from 20% in 2005-2006 to 11% in 2009, with a breakpoint at the end of the first study period (34 patients). Interpretation We found a substantial learning curve; cumulative experience may have contributed to continued reduction of misplacement rate

    Radiation dose optimization in CT planning of corrective scoliosis surgery. A phantom study.

    Get PDF
    The aim of the study was to explore the possibility of obtaining a helical CT scan of a long segment of vertebral column, optimally reduce the radiation dose, compare the radiation dose of the low dose helical CT with that of some of the CT protocols used in clinical practice and finally assess the impact of such a dose reduction on the image quality. A chest phantom was examined with a 16-slice CT scanner. Six scans were performed with different radiation doses. The lowest radiation dose which had no impact on image quality with regard to the information required for surgical planning of patients with scoliosis, was 20 times lower than that of routinely used protocol for CT examination of the spine in children (0.38 mSv vs 7.76 mSv). Patients with scoliosis planned for corrective spinal surgery can be examined with low dose helical CT scan. The dose reduction systems (DRS) available in modern CT scanners contribute to dose reduction and should be used

    Increased rod stiffness improves the degree of deformity correction by segmental pedicle screw fixation in adolescent idiopathic scoliosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There are limited reports in literature studying the impact of rod diameter and stiffness on the degree of deformity correction in patients with AIS.</p> <p>Aims</p> <p>The aims of this study were to evaluate the 3-dimentional deformity correction achieved by segmental pedicle screw fixation in patients with adolescent idiopathic scoliosis, and to find out if learning or the change to stiffer rods had any positive impact on deformity correction.</p> <p>Study design</p> <p>Retrospective study.</p> <p>Methods</p> <p>Plain radiographs and low-dose spine CTs of 116 consecutive patients (aged 15.9 ± 2.8 years) operated during the period 2005-2009 (group 1: patients operated autumn 2005-2006; group 2: 2007; group 3: 2008; group 4: 2009) were retrospectively evaluated.</p> <p>Results</p> <p>There was no statistically significant difference between the correction of the Cobb angle (P = 0.425) or lower end vertebra tilt (P = 0.298) in patients operated during the first versus the remaining periods of the study. No restoration of the sagittal kyphosis was reported in the first period compared with 5.9° in the last study period (P < 0.001). The correction of vertebral rotation was also improved from 4.2° to 7.8° (P < 0.001) for the same periods. For the whole study population, there was statistically significant correlation between the order of the operation (patient number) and the restoration of sagittal kyphosis (r = -0.344, P = 0.001), and the correction of vertebral rotation (r = 0.370, P < 0.001), but not for the Cobb angle or LEVT. However, there was no significant difference in restoration of sagittal kyphosis and the vertebral rotation in the first 17 patients compared with the last 17 patients operated with rods of 5.5 mm diameter (P = 0.621, and 0.941, respectively), indicating that rod stiffness had more impact on the deformity correction than did learning.</p> <p>Conclusions</p> <p>This study showed that rod stiffness had more impact on the deformity correction than did learning.</p

    Measurement of vertebral rotation in adolescent idiopathic scoliosis with low-dose CT in prone position - method description and reliability analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To our knowledge there is no report in the literature on measurements of vertebral rotation with low-dose computed tomography (CT) in prone position.</p> <p>Aims</p> <p>To describe and test the reliability of this new method, compare it with other methods in use and evaluate the influence of body position on the degree of vertebral rotation measured by different radiological methods.</p> <p>Study design</p> <p>Retrospective study.</p> <p>Methods</p> <p>25 consecutive patients with adolescent idiopathic scoliosis scheduled for surgery (17 girls, 8 boys) aged 15 ± 2 years (mean ± SD) were included in the analysis of this study. The degree of the vertebral rotation was in all patients measured according to the method of Perdriolle on standing plain radiographs and on supine CT scanogram, and according to the method of Aaro and Dahlborn on axial CT images in prone position and on magnetic resonance imaging (MRI) in supine position. The measurements were done by one neuroradiologist at two different occasions. Bland and Altman statistical approach was used in the reliability assessment.</p> <p>Results</p> <p>The reliability of measuring vertebral rotation by axial CT images in prone position was almost perfect with an intraclass correlation coefficient of 0.95, a random error of the intraobserver differences of 2.3°, a repeatability coefficient of 3.2° and a coefficient of variation of 18.4%. Corresponding values for measurements on CT scanogram were 0.83, 5.1°, 7.2°, and 32.8%, respectively, indicating lower reliability of the latter modality and method. The degree of vertebral rotation measured on standing plain radiographs, prone CT scanogram, axial images on CT in prone position and on MRI in supine position were 25.7 ± 9.8°, 21.9 ± 8.3°, 17.4 ± 7.1°, and 16.1 ± 6.5°, respectively. The vertebral rotation measured on axial CT images in prone position was in average 7.5% larger than that measured on axial MRI in supine position.</p> <p>Conclusions</p> <p>This study has shown that measurements of vertebral rotation in prone position were more reliable on axial CT images than on CT scanogram. The measurement of vertebral rotation on CT (corrected to the pelvic tilt) in prone position imposes lower impact of the recumbent position on the vertebral rotation than did MRI in supine position. However, the magnitude of differences is of doubtful clinical significance.</p

    Technical aspects of CT imaging of the spine

    Get PDF
    This review article discusses technical aspects of computed tomography (CT) imaging of the spine. Patient positioning, and its influence on image quality and movement artefact, is discussed. Particular emphasis is placed on the choice of scan parameters and their relation to image quality and radiation burden to the patient. Strategies to reduce radiation burden and artefact from metal implants are outlined. Data acquisition, processing, image display and steps to reduce artefact are reviewed. CT imaging of the spine is put into context with other imaging modalities for specific clinical indications or problems. This review aims to review underlying principles for image acquisition and to provide a rough guide for clinical problems without being prescriptive. Individual practice will always vary and reflect differences in local experience, technical provisions and clinical requirements

    Extensive central nervous system involvement in Merkel cell carcinoma: a case report and review of the literature

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Merkel cell carcinoma is a rare malignant cutaneous neoplasm that is locally invasive and frequently metastasizes to lymph nodes, liver, lungs, bone and brain. The incidence of Merkel cell carcinoma has increased in the past three decades.</p> <p>Case presentation</p> <p>A 65-year-old Caucasian man presented with a sudden onset of severe headache and a three-month history of balance disturbance. Magnetic resonance imaging revealed a large meningeal metastasis. The radiologic workup showed retroperitoneal and inguinal lymph node metastases. Biopsy of the inguinal lymph nodes showed metastases of Merkel cell carcinoma. Biopsy from three different suspected skin lesions revealed no Merkel cell carcinoma, and the primary site of Merkel cell carcinoma remained unknown. Leptomeningeal metastases, new axillary lymph node metastases, and intraspinal (epidural and intradural) metastases were detected within six, seven and eight months, respectively, from the start of symptoms despite treating the intracranial metastasis with gamma knife and the abdominal metastases with surgical dissection and external radiotherapy. This indicates the aggressive nature of the disease.</p> <p>Conclusion</p> <p>To the best of our knowledge, this is the first report in the literature of an intracranial meningeal metastasis of Merkel cell carcinoma treated with gamma knife and of intraspinal intradural metastases of Merkel cell carcinoma. Despite good initial response to radiotherapy, recurrence and occurrence of new metastases are common in Merkel cell carcinoma.</p

    Tonsillar ectopia in idiopathic scoliosis: does it play a role in the pathogenesis and prognosis or is it only an incidental finding?

    Get PDF
    ABSTRACT: BACKGROUND: There is an ongoing controversy about the significance of tonsillar ectopia among patients with idiopathic scoliosis (IS). AIM: To find out if tonsillar ectopia occurs more frequently among patients with IS and if it plays any etiological or prognostic role in IS. STUDY DESIGN: Retrospective study. METHODS: Retrospective analysis of 155 consecutive spine MRIs (79 patients with IS and 76 controls; aged 7-25 years; 55% were female) with regard to the position of the cerebellar tonsils in relation to foramen magnum and the sagittal diameter of foramen magnum. All images were evaluated independently by two neuroradiologists. Interobserver and intraobserver reliability analysis was performed by calculation of kappa-value, intraclass correlation coefficient, and systematic and random errors. The occurrence of tonsillar ectopia among patients with IS and controls was estimated and the association of tonsillar ectopia with different predictors has been tested. Statistical significance was set to P </= 0.05. RESULTS: The interobserver and intraobserver agreement with regard to the occurrence of tonsillar ectopia was almost perfect (kappa 0.84 and 0.89, respectively). Tonsillar ectopia was found in 37% of patients with IS compared with 13% among controls (p < 0.001 and odds ratio of 3.8, 95% CI 1.7-8.5). The occurrence of tonsillar ectopia was not associated with the severity of scoliotic deformity (p = 0.85), or rapid progression of scoliosis (p = 0.76). Neurological deficit occurs twice as frequently in patients with tonsillar ectopia as in those with no tonsillar ectopia. Two of five patients with tonsillar ectopia showed improvement of their neurological deficit after the surgical correction of scoliosis. CONCLUSION: As tonsillar ectopia is significantly more frequent among patients with IS and may exhibit some prognostic utility in patients with neurological deficit, we forward the hypothesis that tonsillar ectopia may play a role in the development of the deformity in some patients with IS. However, occurrence of tonsillar ectopia among 13% of controls precludes stating a definitive role of tonsillar ectopia in the pathogenesis of IS. Some patients with IS, tonsillar ectopia and neurological deficit showed neurological improvement following the surgical correction of scoliosis

    Computed tomography measurements of different dimensions of maxillary and frontal sinuses

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We have previously proposed the use of Doppler ultrasound to non-invasively stage sinus infection, as we showed that acoustic streaming could be generated in nonpurulent sinus secretions and helped to distinguish it from mucopurulent sinus secretions. In order to continue this development of a clinically applicable Doppler equipment, we need to determine different dimensions of the paranasal sinuses, especially the thickness of the anterior wall of the maxillary sinus (at the canine fossa). To the best of our knowledge, this is the first report on the thickness of the canine fossa. This study aimed to (a) estimate different dimensions of the maxillary and frontal sinuses measured on computed tomography (CT) of the head, (b) define cut-off values for the normal upper and lower limits of the different measured structures, (c) determine differences in age, side and gender, (d) compare manually and automatically estimated maxillary sinuses volumes, and (e) present incidental findings in the paranasal sinuses among the study patients.</p> <p>Methods</p> <p>Dimensions of 120 maxillary and frontal sinuses from head CTs were measured independently by two radiologists.</p> <p>Results</p> <p>The mean value of the maxillary sinus volume was 15.7 ± 5.3 cm<sup>3 </sup>and significantly larger in males than in females (P = 0.004). There was no statistically significant correlation between the volume of maxillary sinuses with age or side. The mean value of the bone thickness at the canine fossa was 1.1 ± 0.4 mm. The automatically estimated volume of the maxillary sinuses was 14-17% higher than the calculated volume. There was high interobserver agreement with regard to the different measurements performed in this study. Different types of incidental findings of the paranasal sinuses were found in 35% of the patients.</p> <p>Conclusion</p> <p>We presented different dimensions of the maxillary and frontal sinuses on CTs. We believe that our data are necessary for further development of a clinically applicable Doppler equipment for staging rhinosinusitis.</p
    corecore