An analytical model for photomultiplier tube calibration
The purpose of the present publication is to offer an analytical model that
can be used for the calibration of photomultiplier tubes (PMTs). The derivation
of the mathematical formulae involved is discussed extensively and we apply
this machinery to a real problem; the gain determination of the R7081 Hamamatsu
PMT. We hope that our work can provide a third, powerful alternative to the
task of gain deconvolution. We also believe that the techniques explained in
this article can be applied to other problems in PMT calibration and
monitoring
Calibration of the Hamamatsu R7081 photomultiplier tube
The purpose of the present article is to demonstrate the calibration of the
Hamamatsu R7081 photomultiplier using a numerical method based on the Discrete
Fourier Transform (DFT). Conventional techniques, usually employed in the
literature, use approximate models or brute force numerical calculations of the
convolution integrals that lead to the charge response function of the
photomultiplier, S_R(x). In this publication, we explain how a truncated
gaussian model for the single photoelectron amplification can lead to rigorous
results if one leans on the DFT approach. The distinct feature of this
procedure is that S_R(x) is calculated to all orders in the Poisson mean
that characterizes the light intensity and no approximations are needed. The
same scheme can be applied to other photomultiplier tubes that share the same
properties with R7081
Numerical Implementation of lepton-nucleus interactions and its effect on neutrino oscillation analysis
We discuss the implementation of the nuclear model based on realistic nuclear
spectral functions in the GENIE neutrino interaction generator. Besides
improving on the Fermi gas description of the nuclear ground state, our scheme
involves a new prescription for selection, meant to efficiently enforce
energy momentum conservation. The results of our simulations, validated through
comparison to electron scattering data, have been obtained for a variety of
target nuclei, ranging from carbon to argon, and cover the kinematical region
in which quasi elastic scattering is the dominant reaction mechanism. We also
analyse the influence of the adopted nuclear model on the determination of
neutrino oscillation parameters.Comment: 19 pages, 35 figures, version accepted by Phys. Rev.
Determination of muon momentum in the MicroBooNE LArTPC using an improved model of multiple Coulomb scattering
We discuss a technique for measuring a charged particle's momentum by means
of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time
projection chamber (LArTPC). This method does not require the full particle
ionization track to be contained inside of the detector volume as other track
momentum reconstruction methods do (range-based momentum reconstruction and
calorimetric momentum reconstruction). We motivate use of this technique,
describe a tuning of the underlying phenomenological formula, quantify its
performance on fully contained beam-neutrino-induced muon tracks both in
simulation and in data, and quantify its performance on exiting muon tracks in
simulation. Using simulation, we have shown that the standard Highland formula
should be re-tuned specifically for scattering in liquid argon, which
significantly improves the bias and resolution of the momentum measurement.
With the tuned formula, we find agreement between data and simulation for
contained tracks, with a small bias in the momentum reconstruction and with
resolutions that vary as a function of track length, improving from about 10%
for the shortest (one meter long) tracks to 5% for longer (several meter)
tracks. For simulated exiting muons with at least one meter of track contained,
we find a similarly small bias, and a resolution which is less than 15% for
muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first
estimate of the MCS momentum measurement capabilities of MicroBooNE for high
momentum exiting tracks
A Proposal for a Three Detector Short-Baseline Neutrino Oscillation Program in the Fermilab Booster Neutrino Beam
A Short-Baseline Neutrino (SBN) physics program of three LAr-TPC detectors
located along the Booster Neutrino Beam (BNB) at Fermilab is presented. This
new SBN Program will deliver a rich and compelling physics opportunity,
including the ability to resolve a class of experimental anomalies in neutrino
physics and to perform the most sensitive search to date for sterile neutrinos
at the eV mass-scale through both appearance and disappearance oscillation
channels. Using data sets of 6.6e20 protons on target (P.O.T.) in the LAr1-ND
and ICARUS T600 detectors plus 13.2e20 P.O.T. in the MicroBooNE detector, we
estimate that a search for muon neutrino to electron neutrino appearance can be
performed with ~5 sigma sensitivity for the LSND allowed (99% C.L.) parameter
region. In this proposal for the SBN Program, we describe the physics analysis,
the conceptual design of the LAr1-ND detector, the design and refurbishment of
the T600 detector, the necessary infrastructure required to execute the
program, and a possible reconfiguration of the BNB target and horn system to
improve its performance for oscillation searches.Comment: 209 pages, 129 figure
Measurement of cosmic-ray reconstruction efficiencies in the MicroBooNE LArTPC using a small external cosmic-ray counter
The MicroBooNE detector is a liquid argon time projection chamber at Fermilab
designed to study short-baseline neutrino oscillations and neutrino-argon
interaction cross-section. Due to its location near the surface, a good
understanding of cosmic muons as a source of backgrounds is of fundamental
importance for the experiment. We present a method of using an external 0.5 m
(L) x 0.5 m (W) muon counter stack, installed above the main detector, to
determine the cosmic-ray reconstruction efficiency in MicroBooNE. Data are
acquired with this external muon counter stack placed in three different
positions, corresponding to cosmic rays intersecting different parts of the
detector. The data reconstruction efficiency of tracks in the detector is found
to be , in good agreement with the Monte Carlo reconstruction
efficiency . This analysis represents
a small-scale demonstration of the method that can be used with future data
coming from a recently installed cosmic-ray tagger system, which will be able
to tag of the cosmic rays passing through the MicroBooNE
detector.Comment: 19 pages, 12 figure
Indication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment
The Double Chooz Experiment presents an indication of reactor electron
antineutrino disappearance consistent with neutrino oscillations. A ratio of
0.944 0.016 (stat) 0.040 (syst) observed to predicted events was
obtained in 101 days of running at the Chooz Nuclear Power Plant in France,
with two 4.25 GW reactors. The results were obtained from a single 10
m fiducial volume detector located 1050 m from the two reactor cores. The
reactor antineutrino flux prediction used the Bugey4 measurement as an anchor
point. The deficit can be interpreted as an indication of a non-zero value of
the still unmeasured neutrino mixing parameter \sang. Analyzing both the rate
of the prompt positrons and their energy spectrum we find \sang = 0.086
0.041 (stat) 0.030 (syst), or, at 90% CL, 0.015 \sang 0.16.Comment: 7 pages, 4 figures, (new version after PRL referee's comments
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF
The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at
the Fermilab Long-Baseline Neutrino Facility (LBNF) is described
SoLid: A short baseline reactor neutrino experiment
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino energy spectrum and flux and to search for very short distance neutrino oscillations as a probe of eV-scale sterile neutrinos. This paper describes the SoLid detection principle, the mechanical design and the construction of the detector. It then reports on the installation and commissioning on site near the BR2 reactor, Belgium, and finally highlights its performance in terms of detector response and calibration
- …