6 research outputs found

    Novel Applications of Optical Coherence Tomography for Diagnosis and Treatment Monitoring of Patients with Macula-on Retinal Detachment and Age-Related Macular Degeneration

    Get PDF
    In this dissertation, optical coherence tomography is applied in a novel manner to diagnose and monitor the treatment of macula-on retinal detachement and age-related macular degeneration

    Preoperative Posturing of Patients with Macula-On Retinal Detachment Reduces Progression Toward the Fovea

    Get PDF
    Purpose: Traditionally, preoperative posturing consisting of bed rest and positioning is prescribed to patients with macula-on retinal detachment (RD) to prevent RD progression and detachment of the fovea. Execution of such advice can be cumbersome and expensive. This study aimed to investigate if preoperative posturing affects the progression of RD. Design: Prospective cohort study. Participants: Ninety-eight patients with macula-on RD were included. Inclusion criteria were volume optical coherence tomography (OCT) scans could be obtained with sufficient quality; and the smallest distance from the fovea to the detachment border was 1.25 mm or more. Methods: Patients were admitted to the ward for bed rest in anticipation of surgery and were positioned on the side where the RD was mainly located. At baseline and before and after each interruption for meals or toilet visits, a 37°×45° OCT volume scan was performed using a wide-angle Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany). The distance between the nearest point of the RD border and fovea was measured using a custom-built measuring tool. Main Outcome Measures: The RD border displacement and the average RD border displacement velocity moving toward (negative) or away (positive) from the fovea were determined for intervals of posturing and interruptions. Results: The median duration of intervals of posturing was 3.0 hours (interquartile range [IQR], 1.8-14.0 hours; n = 202) and of interruptions 0.37 hours (IQR, 0.26-0.50 hours; n = 197). The median RD border displacement was 2 μm (IQR, -65 to +251 μm) during posturing and -61 μm (IQR, -140 to 0 μm) during interruptions, a statistically significant difference (P < 0.001, Mann-Whitney U test). The median RD border displacement velocity was +1 μm/hour (IQR, -21 to +49 μm/hour) during posturing and -149 μm/hour (IQR, -406 to +1 μm/hour) during interruptions, a statistically significant difference (P < 0.001). Conclusions: By making use of usual interruptions of preoperative posturing we were able to show, in a prospective and ethically acceptable manner, that RD stabilizes during posturing and progresses during interruptions in patients with macula-on RD. Preoperative posturing is effective in reducing progression of RD

    Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice

    Get PDF
    BACKGROUND: A larger thrombus in patients with acute ischemic stroke might result in more complex endovascular treatment procedures, resulting in poorer patient outcomes. Current evidence on thrombus volume and length related to procedural and functional outcomes remains contradicting. This study aimed to assess the prognostic value of thrombus volume and thrombus length and whether this relationship differs between first-line stent retrievers and aspiration devices for endovascular treatment.METHODS: In this multicenter retrospective cohort study, 670 of 3279 patients from the MR CLEAN Registry (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) for endovascularly treated large vessel occlusions were included. Thrombus volume (0.1 mL) and length (0.1 mm) based on manual segmentations and measurements were related to reperfusion grade (expanded Treatment in Cerebral Infarction score) after endovascular treatment, the number of retrieval attempts, symptomatic intracranial hemorrhage, and a shift for functional outcome at 90 days measured with the reverted ordinal modified Rankin Scale (odds ratio &gt;1 implies a favorable outcome). Univariable and multivariable linear and logistic regression were used to report common odds ratios (cORs)/adjusted cOR and regression coefficients (B/aB) with 95% CIs. Furthermore, a multiplicative interaction term was used to analyze the relationship between first-line device choice, stent retrievers versus aspiration device, thrombus volume, and outcomes.RESULTS: Thrombus volume was associated with functional outcome (adjusted cOR, 0.83 [95% CI, 0.71-0.97]) and number of retrieval attempts (aB, 0.16 [95% CI, 0.16-0.28]) but not with the other outcome measures. Thrombus length was only associated with functional independence (adjusted cOR, 0.45 [95% CI, 0.24-0.85]). Patients with more voluminous thrombi had worse functional outcomes if endovascular treatment was based on first-line stent retrievers (interaction cOR, 0.67 [95% CI, 0.50-0.89]; P=0.005; adjusted cOR, 0.74 [95% CI, 0.55-1.0]; P=0.04). CONCLUSIONS: In this study, patients with a more voluminous thrombus required more endovascular thrombus retrieval attempts and had a worse functional outcome. Patients with a lengthier thrombus were less likely to achieve functional independence at 90 days. For more voluminous thrombi, first-line stent retrieval compared with first-line aspiration might be associated with worse functional outcome.</p

    Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice

    No full text
    Background: A larger thrombus in patients with acute ischemic stroke might result in more complex endovascular treatment procedures, resulting in poorer patient outcomes. Current evidence on thrombus volume and length related to procedural and functional outcomes remains contradicting. This study aimed to assess the prognostic value of thrombus volume and thrombus length and whether this relationship differs between first-line stent retrievers and aspiration devices for endovascular treatment. Methods: In this multicenter retrospective cohort study, 670 of 3279 patients from the MR CLEAN Registry (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) for endovascularly treated large vessel occlusions were included. Thrombus volume (0.1 mL) and length (0.1 mm) based on manual segmentations and measurements were related to reperfusion grade (expanded Treatment in Cerebral Infarction score) after endovascular treatment, the number of retrieval attempts, symptomatic intracranial hemorrhage, and a shift for functional outcome at 90 days measured with the reverted ordinal modified Rankin Scale (odds ratio >1 implies a favorable outcome). Univariable and multivariable linear and logistic regression were used to report common odds ratios (cORs)/adjusted cOR and regression coefficients (B/aB) with 95% CIs. Furthermore, a multiplicative interaction term was used to analyze the relationship between first-line device choice, stent retrievers versus aspiration device, thrombus volume, and outcomes. Results: Thrombus volume was associated with functional outcome (adjusted cOR, 0.83 [95% CI, 0.71-0.97]) and number of retrieval attempts (aB, 0.16 [95% CI, 0.16-0.28]) but not with the other outcome measures. Thrombus length was only associated with functional independence (adjusted cOR, 0.45 [95% CI, 0.24-0.85]). Patients with more voluminous thrombi had worse functional outcomes if endovascular treatment was based on first-line stent retrievers (interaction cOR, 0.67 [95% CI, 0.50-0.89]; P=0.005; adjusted cOR, 0.74 [95% CI, 0.55-1.0]; P=0.04). Conclusions: In this study, patients with a more voluminous thrombus required more endovascular thrombus retrieval attempts and had a worse functional outcome. Patients with a lengthier thrombus were less likely to achieve functional independence at 90 days. For more voluminous thrombi, first-line stent retrieval compared with first-line aspiration might be associated with worse functional outcome

    Accelerometry based assessment of gait parameters in children

    No full text
    The objective of this study was to examine if spatio-temporal gait parameters in healthy children can be determined from accelerations measured at the lower trunk as has been demonstrated in adults, previously. Twenty children aged 3-16 years, participated in a protocol that involved repeated walks of different distances in an indoor environment. During walking, accelerations were measured by three orthogonally mounted acceleration sensors in a small wireless device (DynaPort MiniMod) that was attached to the lower back. Based on an inverted pendulum approach, spatio-temporal gait parameters and walking distances were computed from the acceleration signals. Results were compared to video observations and known walking distances and durations. Steps were successfully detected in 99.6+/-0.6% of all observed steps (n=5554). On average, walking distance was accurately estimated (100.6+/-3.3%, range 93-106.7%). No correlation was found between the number of miscounted steps and the total number of steps or the age of the subject. It can be concluded that the use of an inverted pendulum model provides the possibility to estimate spatio-temporal gait parameters in children as well as in adults. The method allows an inexpensive and comfortable assessment of gait parameters in children, is applicable in controlled, indoor environments and could be tested for applicability under free living conditions

    Accelerometry based assessment of gait parameters in children

    No full text
    corecore