    Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT.

    Get PDF
    OBJECTIVES: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. METHODS: The study sample comprised 70 teeth (from the Institut d\u27Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D® CBCT (Carestream Health, Inc., Marne-la-Vallée, France), which has two voxel sizes: 200 µm (CBCT 200 µm group) and 300 µm (CBCT 300 µm group). These teeth had also been scanned with the KODAK 9000 3D® CBCT (Carestream Health, Inc.) (CBCT 76 µm group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, Brüttisellen, Switzerland) (micro-CT 41 µm group) considered as references. After semi-automatic segmentation with AMIRA® software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained. RESULTS: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 µm and 300 µm groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 µm group relative to the two reference groups (Passing-Bablok method). CONCLUSIONS: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed

    Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT.

    Get PDF
    OBJECTIVES: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. METHODS: The study sample comprised 70 teeth (from the Institut d\u27Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D® CBCT (Carestream Health, Inc., Marne-la-Vallée, France), which has two voxel sizes: 200 µm (CBCT 200 µm group) and 300 µm (CBCT 300 µm group). These teeth had also been scanned with the KODAK 9000 3D® CBCT (Carestream Health, Inc.) (CBCT 76 µm group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, Brüttisellen, Switzerland) (micro-CT 41 µm group) considered as references. After semi-automatic segmentation with AMIRA® software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained. RESULTS: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 µm and 300 µm groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 µm group relative to the two reference groups (Passing-Bablok method). CONCLUSIONS: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed

    Accuracy of 3D reconstructions based on cone beam computed tomography.

    No full text
    Three-dimensional imaging of teeth will increase its impact in clinical practice if reconstructions are metrically accurate. We hypothesized that, with cone beam computed tomography (CBCT) data, three-dimensional images of teeth can be reconstructed with the same accuracy and precision as with in vitro micro-computed tomography (micro-CT) data acquisition, the current reference standard. We used a sample of CBCT and micro-CT data taken of tooth germs. Volumes obtained with CBCT and micro-CT devices were statistically similar (n = 120, Passing-Bablok regression). Geometric deviations between CBCT and micro-CT three-dimensional surface reconstructions did not show any areas of important and systematic errors. Future investigations with the use of larger samples may also demonstrate that CBCT data will be helpful for a more in-depth study of other aspects of dental morphology--for example, assessing tooth development. With sufficient accuracy for clinical situations, potential future medical applications of such measurements with CBCT are envisaged
    corecore