40 research outputs found

    A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope

    Get PDF
    Objectives. Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)). Method. Ninety-five nurses and emergency medical technicians were trained to use the AWS, C-MAC, GVL and Macintosh laryngoscope with standard airway trainer manikin and face to face intubation. We compared VCET (vocal cord exposure time), tube pass time, 1st ventilation time, VCET to tube pass time, tube pass time to 1st ventilation time, and POGO (percentage of glottis opening) score. In addition, we compared success rate according to the number of attempts and complications. Result. VCET was similar among all laryngoscopes and POGO score was higher in AWS. AWS and Macintosh blade were faster than GVL and C-MAC in total intubation time. Face to face intubation success rate was lower in GVL than other laryngoscopes. Conclusion. AWS and Macintosh were favorable laryngoscopes in face to face intubation. GVL had disadvantage performing face to face intubation

    Analysis of the Performance for Bystanders’ Cardiopulmonary Resuscitation in Geriatric and Out-of-Hospital Cardiac Arrested Patients

    No full text
    Background: The purpose of this study was to determine if there were changes in bystanders’ chest compression performance and activation of emergency medical services in geriatric and out-of-hospital cardiac patients following the institution of the 2010 International Resuscitation Guidelines and 2008 Good Samaritan Law in South Korea. Methods: This is a retrospective observational study using medical records, and including patient charts and an Utstein Style database in a tertiary hospital. We analyzed the existence of chest compression performance by bystanders, the required time from recognition of cardiac arrest to activation of 119 for emergency medicine services, and the required time from activation of 119 to arrival on the scene from 2005-2014. The data were compared after dividing the years into 2 groups: 2005–2009 and 2010–2014. Results:Of 317 geriatric and out-of-hospital cardiac arrest patients, 261 were eligible for this study. Twelve cases were excluded, and a total of 249 were analyzed. Bystander-initiated chest compression was higher from 2010-2014 than from 2005–2009 (32 [20.13%] and 7 [7.78%], p=0.031, respectively). However, the time required from recognition of cardiac arrest to 119 activation and from 119 activation to arrival was not significantly different between the 2 groups (all p0.05). Conclusion: It is possible that the release of the 2010 International Resuscitation Guidelines and the 2008 Good Samaritan Law may have influenced the potential incremental increase in chest compression performance by a bystander in geriatric and out-of-hospital cardiac arrest patients

    Association between Glasgow Coma Scale in Early Carbon Monoxide Poisoning and Development of Delayed Neurological Sequelae: A Meta-Analysis

    No full text
    A significant number of people experience delayed neurologic sequelae after acute carbon monoxide (CO) poisoning. The Glasgow Coma Scale (GCS) can be used to predict delayed neurologic sequelae occurrence efficiently and without any restrictions. Here, we investigated the association between a low GCS score observed in cases of early CO poisoning and delayed neurologic sequelae development through a meta-analysis. We systematically searched MEDLINE, EMBASE, and the Cochrane Library for studies on GCS as a predictor of delayed neurologic sequelae occurrence in patients with CO poisoning in June 2021. Two reviewers independently extracted study characteristics and pooled data. We also conducted subgroup analyses for the cutoff point for GCS. To assess the risk of bias of each included study, we used the quality in prognosis studies tool. We included 2328 patients from 10 studies. With regard to patients with acute CO poisoning, in the overall pooled odds ratio (OR) of delayed neurologic sequelae development, those with a low GCS score showed a significantly higher value and moderate heterogeneity (OR 2.98, 95% confidence interval (CI) 2.10–4.23, I2 = 33%). Additionally, in subgroup analyses according to the cutoff point of GCS, the development of delayed neurologic sequelae was still significantly higher in the GCS < 9 group (OR 2.80, 95% CI 1.91–4.12, I2 = 34%) than in the GCS < 10 or GCS < 11 groups (OR 4.24, 95% CI 1.55–11.56, I2 = 48%). An initial low GCS score in patients with early CO poisoning was associated with the occurrence of delayed neurologic sequelae. Additionally, GCS was quickly, easily, and accurately assessed. It is therefore possible to predict delayed neurologic sequelae and establish an active treatment strategy, such as hyperbaric oxygen therapy, to minimize neurological sequelae using GCS

    Introduction of Infection Prevention Tracheal Intubation Protocol during the COVID-19 Pandemic Is Not Associated with First-Pass Success Rates of Endotracheal Intubation in the Emergency Department: A Before-and-After Comparative Study

    No full text
    Aerosols and droplets have put healthcare workers performing airway management at high risk of contracting coronavirus disease 2019 (COVID-19). Experts have developed endotracheal intubation (ETI) guidelines and protocols to protect intubators from infection. We aimed to determine whether changes in the emergency department (ED) intubation protocol to prevent COVID-19 infection were associated with first-pass success (FPS) rates in ETI. We used data from the airway management registries in two academic EDs. The study was divided into pre-pandemic (January 2018 to January 2020) and pandemic (February 2020 to February 2022) periods. We selected 2476 intubation cases, including 1151 and 1325 cases recorded before and during the pandemic, respectively. During the pandemic, the FPS rate was 92.2%, which did not change significantly, and major complications increased slightly but not significantly compared with the pre-pandemic period. The OR for the FPS of applying infection prevention intubation protocols was 0.72 (p = 0.069) in a subgroup analysis, junior emergency physicians (PGY1 residents) had an FPS of less than 80% regardless of pandemic protocol implementation. The FPS rate of senior emergency physicians in physiologically difficult airways decreased significantly during the pandemic (98.0% to 88.5%). In conclusion, the FPS rate and complications for adult ETI performed by emergency physicians using COVID-19 infection prevention intubation protocols were similar to pre-pandemic conditions

    Impact of a Smart-Ring-Based Feedback System on the Quality of Chest Compressions in Adult Cardiac Arrest: A Randomized Preliminary Study

    No full text
    This study aimed to assess the effectiveness of a novel chest compression (CC) smart-ring-based feedback system in a manikin simulation. In this randomized, crossover, controlled study, we evaluated the effect of smart-ring CC feedback on cardiopulmonary resuscitation (CPR). The learnability and usability of the tool were evaluated with the System Usability Scale (SUS). Participants were divided into two groups and each performed CCs with and without feedback 2 weeks apart, using different orders. The primary outcome was compression depth; the proportion of accurate-depth (5–6 cm) CCs, CC rate, and the proportion of complete CCs (≀1 cm of residual leaning) were assessed additionally. The feedback group and the non-feedback group showed significant differences in compression depth (52.1 (46.3–54.8) vs. 47.1 (40.5–49.9) mm, p = 0.021). The proportion of accurate-depth CCs was significantly higher in the interventional than in the control condition (88.7 (30.0–99.1) vs. 22.6 (0.0–58.5%), p = 0.033). The mean SUS score was 83.9 ± 8.7 points. The acceptability ranges were ‘acceptable’, and the adjective rating was ‘excellent’. CCs with smart-ring feedback could help achieve the ideal range of depth during CPR. The smart-ring may be a valuable source of CPR feedback

    Recurrent Pulseless Ventricular Tachycardia Induced by Commotio Cordis Treated with Therapeutic Hypothermia

    No full text
    The survival rate of commotio cordis is low, and there is often associated neurological disability if return of spontaneous circulation (ROSC) can be achieved. We report a case of commotio cordis treated with therapeutic hypothermia (TH) that demonstrated a favorable outcome. A 16-year-old female was transferred to our emergency department (ED) for collapse after being struck in the chest with a dodgeball. She has no history of heart problems. She was brought to our ED with pulseless ventricular tachycardia (VT), and ROSC was achieved with defibrillation. She was comatose at our ED and was treated with TH at a target temperature of 33°C for 24 hours. After transfer to the intensive care unit, pulseless VT occurred, and defibrillation was performed twice. She recovered to baseline neurologic status with the exception of some memory difficulties

    Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial

    No full text
    Purpose. Emergency physicians are at risk for infection during invasive procedures, and the respirators can reduce this risk. This study aimed to determine whether endotracheal intubation using direct laryngoscopes affected protection performances of respirators. Methods. A randomized crossover study of 24 emergency physicians was performed. We performed quantitative fit tests using respirators (cup type, fold type without a valve, and fold type with a valve) before and during intubation. The primary outcome was respirators’ fit factors (FF), and secondary outcomes were acceptable protection (percentage of scores above 100 FF [FF%]). Results. 24 pieces of data were analyzed. Compared to fold-type respirator without a valve, FF and FF% values were lower when participants wore a cup-type respirator (200 FF [200-200] versus 200 FF [102.75–200], 100% [78.61–100] versus 74.16% [36.1–98.9]; all P<0.05) or fold-type respirator with a valve (200 FF [200-200] versus 142.5 FF [63.50–200], 100% [76.10–100] versus 62.50% [8.13–100]; all P<0.05). There were no significant differences in intubation time and success rate according to respirator types. Conclusions. Motion during endotracheal intubation using direct laryngoscopes influenced the protective performance of some respirators. Therefore, emergency physicians should identify and wear respirators that provide the best personalized fit for intended tasks
    corecore