34 research outputs found
Performance of the First ANTARES Detector Line
In this paper we report on the data recorded with the first Antares detector
line. The line was deployed on the 14th of February 2006 and was connected to
the readout two weeks later. Environmental data for one and a half years of
running are shown. Measurements of atmospheric muons from data taken from
selected runs during the first six months of operation are presented.
Performance figures in terms of time residuals and angular resolution are
given. Finally the angular distribution of atmospheric muons is presented and
from this the depth profile of the muon intensity is derived.Comment: 14 pages, 9 figure
Time calibration of the ANTARES neutrino telescope
The ANTARES deep-sea neutrino telescope comprises a three-dimensional array of photomultipliers to detect the Cherenkov light induced by upgoing relativistic charged particles originating from neutrino interactions in the vicinity of the detector. The large scattering length of light in the deep sea facilitates an angular resolution of a few tenths of a degree for neutrino energies exceeding 10 TeV. In order to achieve this optimal performance, the time calibration procedures should ensure a relative time calibration between the photomultipliers at the level of similar to 1 ns. The methods developed to attain this level of precision are described
Performance of the front-end electronics of the ANTARES neutrino telescope
ANTARES is a high-energy neutrino telescope installed in the Mediterranean
Sea at a depth of 2475 m. It consists of a three-dimensional array of optical
modules, each containing a large photomultiplier tube. A total of 2700
front-end ASICs named Analogue Ring Samplers (ARS) process the phototube
signals, measure their arrival time, amplitude and shape as well as perform
monitoring and calibration tasks. The ARS chip processes the analogue signals
from the optical modules and converts information into digital data. All the
information is transmitted to shore through further multiplexing electronics
and an optical link. This paper describes the performance of the ARS chip;
results from the functionality and characterization tests in the laboratory are
summarized and the long-term performance in the apparatus is illustrated.Comment: 20 pages, 22 figures, published in Nuclear Instruments and Methods
The SUrvey for Pulsars and Extragalactic Radio Bursts â II. New FRB discoveries and their follow-up
We report the discovery of four Fast Radio Bursts (FRBs) in the ongoing SUrvey for Pulsars and Extragalactic Radio Bursts at the Parkes Radio Telescope: FRBs 150610, 151206, 151230 and 160102. Our real-time discoveries have enabled us to conduct extensive, rapid multimessenger follow-up at 12 major facilities sensitive to radio, optical, X-ray, gamma-ray photons and neutrinos on time-scales ranging from an hour to a few months post-burst. No counterparts to the FRBs were found and we provide upper limits on afterglow luminosities. None of the FRBs were seen to repeat. Formal fits to all FRBs show hints of scattering while their intrinsic widths are unresolved in time. FRB 151206 is at low Galactic latitude, FRB 151230 shows a sharp spectral cut-off, and FRB 160102 has the highest dispersion measure (DM = 2596.1 ± 0.3âpcâcmâ3) detected to date. Three of the FRBs have high dispersion measures (DM > 1500âpcâcmâ3), favouring a scenario where the DM is dominated by contributions from the intergalactic medium. The slope of the Parkes FRB source counts distribution with fluences >2âJyâms is α=â2.2+0.6â1.2 and still consistent with a Euclidean distribution (α = â3/2). We also find that the all-sky rate is 1.7+1.5â0.9Ă103 FRBs/(4Ï sr)/day above âŒ2Jyms and there is currently no strong evidence for a latitude-dependent FRB sky rate
The positioning system of the ANTARES Neutrino Telescope
The ANTARES neutrino telescope, located 40km off the coast of Toulon in the Mediterranean Sea at a mooring depth of about 2475m, consists of twelve detection lines equipped typically with 25 storeys. Every storey carries three optical modules that detect Cherenkov light induced by charged secondary particles (typically muons) coming from neutrino interactions. As these lines are flexible structures fixed to the sea bed and held taut by a buoy, sea currents cause the lines to move and the storeys to rotate. The knowledge of the position of the optical modules with a precision better than 10cm is essential for a good reconstruction of particle tracks. In this paper the ANTARES positioning system is described. It consists of an acoustic positioning system, for distance triangulation, and a compass-tiltmeter system, for the measurement of the orientation and inclination of the storeys. Necessary corrections are discussed and the results of the detector alignment procedure are described
Risk profiles and one-year outcomes of patients with newly diagnosed atrial fibrillation in India: Insights from the GARFIELD-AF Registry.
BACKGROUND: The Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) is an ongoing prospective noninterventional registry, which is providing important information on the baseline characteristics, treatment patterns, and 1-year outcomes in patients with newly diagnosed non-valvular atrial fibrillation (NVAF). This report describes data from Indian patients recruited in this registry. METHODS AND RESULTS: A total of 52,014 patients with newly diagnosed AF were enrolled globally; of these, 1388 patients were recruited from 26 sites within India (2012-2016). In India, the mean age was 65.8 years at diagnosis of NVAF. Hypertension was the most prevalent risk factor for AF, present in 68.5% of patients from India and in 76.3% of patients globally (P < 0.001). Diabetes and coronary artery disease (CAD) were prevalent in 36.2% and 28.1% of patients as compared with global prevalence of 22.2% and 21.6%, respectively (P < 0.001 for both). Antiplatelet therapy was the most common antithrombotic treatment in India. With increasing stroke risk, however, patients were more likely to receive oral anticoagulant therapy [mainly vitamin K antagonist (VKA)], but average international normalized ratio (INR) was lower among Indian patients [median INR value 1.6 (interquartile range {IQR}: 1.3-2.3) versus 2.3 (IQR 1.8-2.8) (P < 0.001)]. Compared with other countries, patients from India had markedly higher rates of all-cause mortality [7.68 per 100 person-years (95% confidence interval 6.32-9.35) vs 4.34 (4.16-4.53), P < 0.0001], while rates of stroke/systemic embolism and major bleeding were lower after 1 year of follow-up. CONCLUSION: Compared to previously published registries from India, the GARFIELD-AF registry describes clinical profiles and outcomes in Indian patients with AF of a different etiology. The registry data show that compared to the rest of the world, Indian AF patients are younger in age and have more diabetes and CAD. Patients with a higher stroke risk are more likely to receive anticoagulation therapy with VKA but are underdosed compared with the global average in the GARFIELD-AF. CLINICAL TRIAL REGISTRATION-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01090362
Measurement, monitoring and knowledge of blood pressure: May Measurement Month, Colombia 2017
To describe the findings of implementing May Measurement Month 2017 in the adult Colom-bian population to raise awareness of the importance of blood pressure measuring, monitoring,and [email protected]
Measurement, monitoring and knowledge of blood pressure: May Measurement Month, Colombia 2017
To describe the findings of implementing May Measurement Month 2017 in the adult Colom-bian population to raise awareness of the importance of blood pressure measuring, monitoring,and awareness