1,825 research outputs found
Desalination effluents and the establishment of the non-indigenous skeleton shrimp Paracaprella pusilla Mayer, 1890 in the south-eastern Mediterranean
A decade long monitoring programme has revealed a flourishing population of the non-indigenous skeleton shrimp Paracaprella pusilla in the vicinity of outfalls of desalination plants off the Mediterranean coast of Israel. The first specimens were collected in 2010, thus predating all previously published records of this species in the Mediterranean Sea. A decade-long disturbance regime related to the construction and operation of the plants may have had a critical role in driving the population growth
Recommended from our members
Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation.
Ablation of the left atrium using either radiofrequency (RF) or cryothermal energy is an effective treatment for atrial fibrillation (AF) and is the most frequent type of cardiac ablation procedure performed. Although generally safe, collateral injury to surrounding structures, particularly the esophagus, remains a concern. Cooling or warming the esophagus to counteract the heat from RF ablation, or the cold from cryoablation, is a method that is used to reduce thermal esophageal injury, and there are increasing data to support this approach. This protocol describes the use of a commercially available esophageal temperature management device to cool or warm the esophagus to reduce esophageal injury during left atrial ablation. The temperature management device is powered by standard water-blanket heat exchangers, and is shaped like a standard orogastric tube placed for gastric suctioning and decompression. Water circulates through the device in a closed-loop circuit, transferring heat across the silicone walls of the device, through the esophageal wall. Placement of the device is analogous to the placement of a typical orogastric tube, and temperature is adjusted via the external heat-exchanger console
Characterization of a proximal Sp1 response element in the mouse Dlk2 gene promoter
<p>Abstract</p> <p>Background</p> <p>DLK2 is an EGF-like membrane protein, closely related to DLK1, which is involved in adipogenesis. Both proteins interact with the NOTCH1 receptor and are able to modulate its activation. The expression of the gene <it>Dlk2 </it>is coordinated with that of <it>Dlk1 </it>in several tissues and cell lines. Unlike <it>Dlk1</it>, the mouse <it>Dlk2 </it>gene and its locus at chromosome 17 are not fully characterized.</p> <p>Results</p> <p>The goal of this work was the characterization of <it>Dlk2 </it>mRNA, as well as the analysis of the mechanisms that control its basal transcription. First, we analyzed the <it>Dlk2 </it>transcripts expressed by several mouse cells lines and tissues, and mapped the transcription start site by 5' Rapid Amplification of cDNA Ends. <it>In silico </it>analysis revealed that <it>Dlk2 </it>possesses a TATA-less promoter containing minimal promoter elements associated with a CpG island, and sequences for Inr and DPE elements. Besides, it possesses six GC-boxes, considered as consensus sites for the transcription factor Sp1. Indeed, we report that Sp1 directly binds to the <it>Dlk2 </it>promoter, activates its transcription, and regulates its level of expression.</p> <p>Conclusions</p> <p>Our results provide the first characterization of <it>Dlk2 </it>transcripts, map the location of the <it>Dlk2 </it>core promoter, and show the role of Sp1 as a key regulator of <it>Dlk2 </it>transcription, providing new insights into the molecular mechanisms that contribute to the expression of the <it>Dlk2 </it>gene.</p
Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.
PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA
Tissue drives lesion: computational evidence of interspecies variability in cardiac radiofrequency ablation
Radiofrequency catheter ablation (RFCA) is widely used for the treatment of various types of cardiac arrhythmias. Typically, the efficacy and the safety of the ablation protocols used in the clinics are derived from tests carried out on animal specimens, including swines. However, these experimental findings cannot be immediately translated to clinical practice on human patients, due to the difference in the physical properties of the types of tissue. Computational models can assist in the quantification of this variability and can provide insights in the results of the RFCA for different species. In this work, we consider a standard ablation protocol of 10g force, 30W power for 30s. We simulate its application on a porcine cardiac tissue, a human ventricle and a human atrium. Using a recently developed computational model that accounts for the mechanical properties of the tissue, we explore the onset and the growth of the lesion along time by tracking its depth and width, and we compare the lesion size and dimensions at the end of the ablation
The use of remote monitoring of cardiac implantable devices during the COVID-19 pandemic: an EHRA physician survey
It is unclear to what extent the COVID-19 pandemic has influenced the use of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs). The present physician-based European Heart Rhythm Association (EHRA) survey aimed to assess the influence of the COVID-19 pandemic on RM of CIEDs among EHRA members and how it changed the current practice. The survey comprised 27 questions focusing on RM use before and during the pandemic. Questions focused on the impact of COVID-19 on the frequency of in-office visits, data filtering, reasons for initiating in-person visits, underutilization of RM during COVID-19, and RM reimbursement. A total of 160 participants from 28 countries completed the survey. Compared to the pre-pandemic period, there was a significant increase in the use of RM in patients with pacemakers (PMs) and implantable loop recorders (ILRs) during the COVID-19 pandemic (PM 24.2 vs. 39.9%, P = 0.002; ILRs 61.5 vs. 73.5%, P = 0.028), while there was a trend towards higher utilization of RM for cardiac resynchronization therapy-pacemaker (CRT-P) devices during the pandemic (44.5 vs. 55%, P = 0.063). The use of RM with implantable cardioverter-defibrillators (ICDs) and CRT-defibrillator (CRT-D) did not significantly change during the pandemic (ICD 65.2 vs. 69.6%, P = 0.408; CRT-D 65.2 vs. 68.8%, P = 0.513). The frequency of in-office visits was significantly lower during the pandemic (P < 0.001). Nearly two-thirds of participants (57 out of 87 respondents), established new RM connections for CIEDs implanted before the pandemic with 33.3% (n = 29) delivering RM transmitters to the patient's home address, and the remaining 32.1% (n = 28) activating RM connections during an in-office visit. The results of this survey suggest that the crisis caused by COVID-19 has led to a significant increase in the use of RM of CIEDs
Crystal sedimentation and stone formation
Mechanisms of crystal collision being the first step of aggregation (AGN) were analyzed for calcium oxalate monohydrate (COM) directly produced in urine. COM was produced by oxalate titration in urine of seven healthy men, in solutions of urinary macromolecules and in buffered distilled water (control). Crystal formation and sedimentation were followed by a spectrophotometer and analyzed by scanning electron microscopy. Viscosity of urine was measured at 37°C. From results, sedimentation rate (vS), particle diffusion (D) and incidences of collision of particles in suspension by sedimentation (IS) and by diffusion (ID) were calculated. Calculations were related to average volume and urinary transit time of renal collecting ducts (CD) and of renal pelvis. vS was in urine 0.026 ± 0.012, in UMS 0.022 ± 0.01 and in control 0.091 ± 0.02 cm min−1 (mean ± SD). For urine, a D of 9.53 ± 0.97 μm within 1 min can be calculated. At maximal crystal concentration, IS was only 0.12 and ID was 0.48 min−1 cm−3 which, even at an unrealistic permanent and maximal crystalluria, would only correspond to less than one crystal collision/week/CD, whereas to the same tubular wall being in horizontal position 1.3 crystals/min and to a renal stone 624 crystals/cm2 min could drop by sedimentation. Sedimentation to renal tubular or pelvic wall, where crystals can accumulate and meet with a tissue calcification or a stone, is probably essential for stone formation. Since vS mainly depends on particle size, reducing urinary supersaturation and crystal growth by dietary oxalate restriction seems to be an important measure to prevent aggregation
- …