510 research outputs found
Tests of cosmic ray radiography for power industry applications
In this report, we assess muon multiple scattering tomography as a
non-destructive inspection technique in several typical areas of interest to
the nuclear power industry, including monitoring concrete degradation, gate
valve conditions, and pipe wall thickness. This work is motivated by the need
for radiographic methods that do not require the licensing, training, and
safety controls of x-rays, and by the need to be able to penetrate considerable
overburden to examine internal details of components that are otherwise
inaccessible, with minimum impact on industrial operations. In some scenarios,
we find that muon tomography may be an attractive alternative to more typical
measurements.Comment: LA-UR-15-2212
A New Limit on the Neutrinoless DBD of 130Te
We report the present results of CUORICINO a cryogenic experiment on
neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62
crystals of TeO2 with a total active mass of 40.7 kg. The array is framed
inside of a dilution refrigerator, heavily shielded against environmental
radioactivity and high-energy neutrons, and operated at a temperature of ~8 mK
in the Gran Sasso Underground Laboratory. Temperature pulses induced by
particle interacting in the crystals are recorded and measured by means of
Neutron Transmutation Doped thermistors. The gain of each bolometer is
stabilized with voltage pulses developed by a high stability pulse generator
across heater resistors put in thermal contact with the absorber.
The calibration is performed by means of two thoriated wires routinely
inserted in the set-up. No evidence for a peak indicating neutrinoless DBD of
130Te is detected and a 90% C.L. lower limit of 1.8E24 years is set for the
lifetime of this process. Taking largely into account the uncertainties in the
theoretical values of nuclear matrix elements, this implies an upper boud on
the effective mass of the electron neutrino ranging from 0.2 to 1.1 eV. This
sensitivity is similar to those of the 76Ge experiments.Comment: 4 pages, 2 figure
Double-beta decay of Te to the first 0 excited state of Xe with CUORICINO
The CUORICINO experiment was an array of 62 TeO single-crystal
bolometers with a total Te mass of kg. The experiment finished
in 2008 after more than 3 years of active operating time. Searches for both
and double-beta decay to the first excited state in
Xe were performed by studying different coincidence scenarios. The
analysis was based on data representing a total exposure of
N(Te)t=y. No evidence for a signal was
found. The resulting lower limits on the half lives are y (90% C.L.), and
y (90%
C.L.).Comment: 6 pages, 4 figure
Imaging the inside of thick structures using cosmic rays
The authors present here a new method to image reinforcement elements inside
thick structures and the results of a demonstration measurement performed on a
mock-up wall built at Los Alamos National Laboratory. The method, referred to
as "multiple scattering muon radiography", relies on the use of cosmic-ray
muons as probes. The work described in this article was performed to prove the
viability of the technique as a means to image the interior of the dome of
Florence Cathedral Santa Maria del Fiore, one of the UNESCO World Heritage
sites and among the highest profile buildings in existence. Its result shows
the effectiveness of the technique as a tool to radiograph thick structures and
image denser object inside them
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
We present results of a dark matter search performed with a 0.6 kg day
exposure of the DAMIC experiment at the SNOLAB underground laboratory. We
measure the energy spectrum of ionization events in the bulk silicon of
charge-coupled devices down to a signal of 60 eV electron equivalent. The data
are consistent with radiogenic backgrounds, and constraints on the
spin-independent WIMP-nucleon elastic-scattering cross section are accordingly
placed. A region of parameter space relevant to the potential signal from the
CDMS-II Si experiment is excluded using the same target for the first time.
This result obtained with a limited exposure demonstrates the potential to
explore the low-mass WIMP region (<10 GeV/) of the upcoming DAMIC100, a
100 g detector currently being installed in SNOLAB.Comment: 11 pages, 11 figure
Gigahertz (GHz) hard x-ray imaging using fast scintillators
Gigahertz (GHz) imaging technology will be needed at high-luminosity X-ray and charged particle sources. It is plausible to combine fast scintillators with the latest picosecond detectors and GHz electronics for multi-frame hard Xray imaging and achieve an inter-frame time of less than 10 ns. The time responses and light yield of LYSO, LaBr_3, BaF_2 and ZnO are measured using an MCP-PMT detector. Zinc Oxide (ZnO) is an attractive material for fast hard X-ray imaging based on GEANT4 simulations and previous studies, but the measured light yield from the samples is much lower than expected
- …