90 research outputs found
The Quantum Speed Limit of Optimal Controlled Phasegates for Trapped Neutral Atoms
We study controlled phasegates for ultracold atoms in an optical potential. A
shaped laser pulse drives transitions between the ground and electronically
excited states where the atoms are subject to a long-range 1/R^3 interaction.
We fully account for this interaction and use optimal control theory to
calculate the pulse shapes. This allows us to determine the minimum pulse
duration, respectively, gate time T that is required to obtain high fidelity.
We accurately analyze the speed limiting factors, and we find the gate time to
be limited either by the interaction strength in the excited state or by the
ground state vibrational motion in the trap. The latter needs to be resolved by
the pulses in order to fully restore the motional state of the atoms at the end
of the gate.Comment: 11 pages, 10 figures, 1 tabl
Recommended from our members
Low-profile high-voltage compact gas switch
This paper discusses the development and testing of a low-profile, high-voltage, spark-gap switch designed to be closely coupled with other components into an integrated high-energy pulsed-power source. The switch is designed to operate at 100 kV using SF6 gas pressurized to less than 0.7 MPa. The volume of the switch cavity region is less than 1.5 cm3, and the field stress along the gas-dielectric interface is as high as 130 kV/cm. The dielectric switch body has a low profile that is only I -cm tall at its greatest extent and nominally 2-mm thick over most of its area. This design achieves a very low inductance of less than 5 nH, but results in field stresses exceeding 500 kV/cm in the dielectric material. Field modeling was done to determine the appropriate shape for the highly stressed insulator and electrodes, and special manufacturing techniques were employed to mitigate the usual mechanisms that induce breakdown and failure in solid dielectrics. Static breakdown tests verified that the switch operates satisfactorily at 100 kV levels. The unit has been characterized with different shaped electrodes having nominal gap spacings of 2.0, 2.5, and 3.0 mm. The relationship between self-break voltage and operating pressure agrees well with published data on gas properties, accounting for the field enhancements of the electrode shapes being used. Capacitor discharge tests in a low inductance test fixture exhibited peak currents up to 25 kA with characteristic frequencies of the ringdown circuit ranging from 10 to 20 MHz. The ringdown waveforms and scaling of measured parameters agree well with circuit modeling of the switch and test fixture. Repetitive operation has been demonstrated at moderate rep-rates up to 15 Hz, limited by the power supply being used. Preliminary tests to evaluate lifetime of the compact switch assembly have been encouraging. In one case, after more than 7,000 high-current ringdown tests with approximately 30 C of total charge transferred, the switch continued to operate satisfactorily with no apparent tracking or deterioration of the insulator
Measuring helical FCG voltage with an electric field antenna
A method of measuring the voltage produced by a helical explosive flux compression generator using a remote electric field antenna is described in detail. The diagnostic has been successfully implemented on several experiments. Measured data from the diagnostic compare favorably with voltages predicted using the code CAGEN, validating our predictive modeling tools. The measured data is important to understanding generator performance, and is measured with a low-risk, minimally intrusive approach
Recommended from our members
Products of motor burnout. Final report
The Montreal Protocol of 1987 effectively banned a long list of chlorofluorocarbons (CFCs) traditionally used in air conditioning and refrigeration applications. The refrigeration and air conditioning industries have responded by developing and testing new, alternative refrigerants that are less damaging to the atmosphere upon release. Despite a reputation for quality and reliability, air conditioning systems do occasionally fail. One of the more common failure modes in a hermetic system is a motor burnout. Motor burnouts can occur by various mechanisms. One of the most common scenarios is a locked motor rotor, which may result from a damaged bearing. The resulting electrical motor burnout is caused by overheating of the locked rotor and subsequent failure of the insulation. This is primarily a thermal breakdown process
Recommended from our members
Electrostatic Modeling of Vacuum Insulator Triple Junctions
Triple junctions are often initiation points for insulator flashover in pulsed power devices. The two-dimensional finite-element TriComp [1] modeling software suite was utilized for its electrostatic field modeling package to investigate electric field behavior in the anode and cathode triple junctions of a high voltage vacuum-insulator interface. TriComp enables simple extraction of values from a macroscopic solution for use as boundary conditions in a subset solution. Electric fields computed with this zoom capability correlate with theoretical analysis of the anode and cathode triple junctions within submicron distances for nominal electrode spacing of 1.0 cm. This paper will discuss the iterative zoom process with TriComp finite-element software and the corresponding theoretical verification of the results
Recommended from our members
Study of Vacuum Insulator Flashover for Pulse Lengths of Multi-Microseconds
We are studying the flashover of vacuum insulators for applications where high voltage conditioning of the insulator and electrodes is not practical and for pulse lengths on the order of several microseconds. The study is centered about experiments performed with a 100-kV, 10-ms pulsed power system and supported by a combination of theoretical and computational modeling. The base line geometry is a cylindrically symmetric, +45{sup o} insulator between flat electrodes. In the experiments, flashovers or breakdowns are localized by operating at field stresses slightly below the level needed for explosive emissions with the base line geometry. The electrodes and/or insulator are then seeded with an emission source, e.g. a tuft of velvet, or a known mechanical defect. Various standard techniques are employed to suppress cathode-originating flashovers/breakdowns. We present the results of our experiments and discuss the capabilities of modeling insulator flashover
Recommended from our members
Understanding and Improving High Voltage Vacuum Insulators for Microsecond Pulses
High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delivery of pulsed power into a vacuum region is the most critical aspect of operation. The surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This mode of breakdown, called surface flashover, imposes serious limitations on the power flow into a vacuum region. This is especially troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and for applications where relatively long pulses, on the order of several microseconds, are required. The goal of this project is to establish a sound fundamental understanding of the mechanisms that lead to surface flashover, and then evaluate the most promising techniques to improve vacuum insulators and enable high voltage operation at stress levels near the intrinsic bulk breakdown limits of the material. The approach we proposed and followed was to develop this understanding through a combination of theoretical and computation methods coupled with experiments to validate and quantify expected behaviors. In this report we summarize our modeling and simulation efforts, theoretical studies, and experimental investigations. The computational work began by exploring the limits of commercially available codes and demonstrating methods to examine field enhancements and defect mechanisms at microscopic levels. Plasma simulations with particle codes used in conjunction with circuit models of the experimental apparatus enabled comparisons with experimental measurements. The large scale plasma (LSP) particle-in-cell (PIC) code was run on multiprocessor platforms and used to simulate expanding plasma conditions in vacuum gap regions. Algorithms were incorporated into LSP to handle secondary electron emission from dielectric materials to enable detailed simulations of flashover phenomenon. Theoretical studies were focused on explaining a possible mechanism for anode initiated surface flashover that involves an electron avalanche process starting near the anode, not a mechanism involving bulk dielectric breakdown. Experiments were performed in Engineering's Pulsed Power Lab using an available 100-kV, 10-{micro}s pulse generator and vacuum chamber. The initial experiments were done with polyethylene insulator material in the shape of a truncated cone cut at +45{sup o} angle between flat electrodes with a gap of 1.0 cm. The insulator was sized so there were no flashovers or breakdowns under nominal operating conditions. Insulator flashover or gap closure was induced by introducing a plasma source, a tuft of velvet, in proximity to the insulator or electrode
Development of the vacuum power flow channel for the Mini-G
Abstract not provide
Recommended from our members
Understanding High Voltage Vacuum Insulators for Microsecond Pulses
High voltage insulation is one of the main areas of pulsed power research and development since the surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This is troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and where relatively long pulses, on the order of several microseconds, are required. Here we give a summary of our approach to modeling and simulation efforts and experimental investigations for understanding flashover mechanism. The computational work is comprised of both filed and particle-in-cell modeling with state-of-the-art commercial codes. Experiments were performed in using an available 100-kV, 10-{micro}s pulse generator and vacuum chamber. The initial experiments were done with polyethylene insulator material in the shape of a truncated cone cut at +45{sup o} angle between flat electrodes with a gap of 1.0 cm. The insulator was sized so there were no flashovers or breakdowns under nominal operating conditions. Insulator flashover or gap closure was induced by introducing a plasma source, a tuft of velvet, in proximity to the insulator or electrode
Flat plate FCG experimental system for material studies
Abstract not provide
- …