92 research outputs found

    Study of SVOM/ECLAIRs inhomogeneities in the detection plane below 8 keV and their mitigation for the trigger performances

    Full text link
    The Space-based multi-band astronomical Variable Objects Monitor (SVOM) is a Chinese-French mission dedicated to the study of the transient sky. It is scheduled to start operations in 2024. ECLAIRs is a coded-mask telescope with a large field of view. It is designed to detect and localize gamma-ray bursts (GRBs) in the energy range from 4 keV up to 120 keV. In 2021, the ECLAIRs telescope underwent various calibration campaigns in vacuum test-chambers to evaluate its performance. Between 4 and 8 keV, the counting response of the detection plane shows inhomogeneities between pixels from different production batches. The efficiency inhomogeneity is caused by low-efficiency pixels (LEPs) from one of the two batches, together with high-threshold pixels (HTPs) whose threshold was raised to avoid cross-talk effects. In addition, some unexpected noise was found in the detection plane regions close to the heat pipes. We study the impact of these inhomogeneities and of the heat-pipe noise at low energies on the ECLAIRs onboard triggers. We propose different strategies in order to mitigate these impacts and to improve the onboard trigger performance. We analyzed the data from the calibration campaigns and performed simulations with the ground model of the ECLAIRs trigger software in order to design and evaluate the different strategies. Most of the impact of HTPs can be corrected for by excluding HTPs from the trigger processing. To correct for the impact of LEPs, an efficiency correction in the shadowgram seems to be a good solution. An effective solution for the heat-pipe noise is selecting the noisy pixels and ignoring their data in the 4--8 keV band during the data analysis.Comment: Accepted for publication in Astronomy&Astrophysics Accepted for publication in Astronomy&Astrophysics Accepted for publication in Astronom

    Influence of the Earth on the background and the sensitivity of the GRM and ECLAIRs instruments aboard the Chinese-French mission SVOM

    Full text link
    SVOM (Space-based multi-band astronomical Variable Object Monitor) is a future Chinese-French satellite mission which is dedicated to Gamma-Ray Burst (GRB) studies. Its anti-solar pointing strategy makes the Earth cross the field of view of its payload every orbit. In this paper, we present the variations of the gamma-ray background of the two high energy instruments aboard SVOM, the Gamma-Ray Monitor (GRM) and ECLAIRs, as a function of the Earth position. We conclude with an estimate of the Earth influence on their sensitivity and their GRB detection capability.Comment: 24 pages, 15 figures, accepted for publication in Experimental Astronom

    Analysis of nucleic acid chaperoning by the prion protein and its inhibition by oligonucleotides

    Get PDF
    Prion diseases are unique neurodegenerative illnesses associated with the conversion of the cellular prion protein (PrPC) into the aggregated misfolded scrapie isoform, named PrPSc. Recent studies on the physiological role of PrPC revealed that this protein has probably multiple functions, notably in cell–cell adhesion and signal transduction, and in assisting nucleic acid folding. In fact, in vitro findings indicated that the human PrP (huPrP) possesses nucleic acid binding and annealing activities, similarly to nucleic acid chaperone proteins that play essential roles in cellular DNA and RNA metabolism. Here, we show that a peptide, representing the N-terminal domain of huPrP, facilitates nucleic acid annealing by two parallel pathways nucleated through the stem termini. We also show that PrP of human or ovine origin facilitates DNA strand exchange, ribozyme-directed cleavage of an RNA template and RNA trans-splicing in a manner similar to the nucleocapsid protein of HIV-1. In an attempt to characterize inhibitors of PrP-chaperoning in vitro we discovered that the thioaptamer 5′-GACACAAGCCGA-3′ was extensively inhibiting the PrP chaperoning activities. At the same time a recently characterized methylated oligoribonucleotide inhibiting the chaperoning activity of the HIV-1 nucleocapsid protein was poorly impairing the PrP chaperoning activities

    The HIV-1 transcriptional activator Tat has potent nucleic acid chaperoning activities in vitro

    Get PDF
    The human immunodeficiency virus type 1 (HIV-1) is a primate lentivirus that causes the acquired immunodeficiency syndrome (AIDS). In addition to the virion structural proteins and enzyme precursors, that are Gag, Env and Pol, HIV-1 encodes several regulatory proteins, notably a small nuclear transcriptional activator named Tat. The Tat protein is absolutely required for virus replication since it controls proviral DNA transcription to generate the full-length viral mRNA. Tat can also regulate mRNA capping and splicing and was recently found to interfere with the cellular mi- and siRNA machinery. Because of its extensive interplay with nucleic acids, and its basic and disordered nature we speculated that Tat had nucleic acid-chaperoning properties. This prompted us to examine in vitro the nucleic acid-chaperoning activities of Tat and Tat peptides made by chemical synthesis. Here we report that Tat has potent nucleic acid-chaperoning activities according to the standard DNA annealing, DNA and RNA strand exchange, RNA ribozyme cleavage and trans-splicing assays. The active Tat(44–61) peptide identified here corresponds to the smallest known sequence with DNA/RNA chaperoning properties

    Electrochemical Glucose Sensors—Developments Using Electrostatic Assembly and Carbon Nanotubes for Biosensor Construction

    Get PDF
    In 1962, Clark and Lyons proposed incorporating the enzyme glucose oxidase in the construction of an electrochemical sensor for glucose in blood plasma. In their application, Clark and Lyons describe an electrode in which a membrane permeable to glucose traps a small volume of solution containing the enzyme adjacent to a pH electrode, and the presence of glucose is detected by the change in the electrode potential that occurs when glucose reacts with the enzyme in this volume of solution. Although described nearly 50 years ago, this seminal development provides the general structure for constructing electrochemical glucose sensors that is still used today. Despite the maturity of the field, new developments that explore solutions to the fundamental limitations of electrochemical glucose sensors continue to emerge. Here we discuss two developments of the last 15 years; confining the enzyme and a redox mediator to a very thin molecular films at electrode surfaces by electrostatic assembly, and the use of electrodes modified by carbon nanotubes (CNTs) to leverage the electrocatalytic effect of the CNTs to reduce the oxidation overpotential of the electrode reaction or for the direct electron transport to the enzyme

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Full text link
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental Astronomy with minor editin

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033

    Greffons osseux autogènes intra-oraux en implantologie

    No full text
    LYON1-BU Santé Odontologie (693882213) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF

    Arguments for a Relationship Between Malnutrition and Epilepsy

    No full text
    International audienceMalnutrition and epilepsy are two major health issues, essentially in developing countries. Malnutrition is responsible for moderate to severe disabilities. Several studies performed on animal models or humans highlight the possible adverse effects of malnutrition on the occurrence of seizures or epilepsy. Low protein diet and certain micronutrient deficiencies as vitamins, trace-elements, or electrolytes are involved. In contrast, a ketogenic diet (high fat and low carbohydrate) can be used in the treatment of severe epilepsy. In developing countries, there are a lot of beliefs around epilepsy (origin, contagiousness of epilepsy, and so on). Sociocultural attitudes as food taboos and social stigma can be responsible for a negative impact on the nutritional status of people with epilepsy. Antiepileptic drugs or traditional treatments can also be responsible for malnutrition.A link between malnutrition and epilepsy has been suspected for many years. But scientific data in humans are scarce. Two different hypotheses can be put forward: malnutrition predisposing to seizure/epilepsy or epilepsy predisposing to malnutrition. The mechanisms implicated, here are as various as decrease of seizure threshold, altered neurotransmission, or anorexia induced by antiepileptic drugs. A better understanding of these interactions is necessary. In the mean time, malnutrition has to be prevented and treated
    corecore