5 research outputs found

    Radiotherapy for large cutaneous angiosarcoma of face with RapidArc (VMAT)

    Get PDF
    Angiosarcoma is a rare malignancy of vascular origin. It can affect any part of the body, head and neck region being probably the most common site of diagnosis. We present here a case of Angiosarcoma of face in a 67-year-old elderly gentleman who was treated with RapidArc – volumetric modulated arc therapy (VMAT) for recurrence after surgery, radiotherapy and chemotherapy. As an alternative to Electron Beam Therapy, RapidArc with skin bolus can be considered for large complex shaped targets with irregular surface and tissue inhomogeneity. RapidArc plan can achieve adequate target coverage with acceptable dose homogeneity and conformity

    Comparative dosimetric analysis of IMRT and VMAT (RapidArc) in brain, head and neck, breast and prostate malignancies

    Get PDF
    Purpose: Intensity modulated radiotherapy (IMRT) in the recent past has established itself as a gold standard for organs at risk (OAR) sparing, target coverage and dose conformity. With the advent of a rotational treatment technology such as volumetric modulated arc therapy (VMAT), an inter-comparison is warranted to address the advantages and disadvantages of each technique. Methods: Twenty patients were selected retrospectively from our patient database. Sites included were brain, head and neck, chest wall, and prostate, with five patients for each site. For all the selected patients, both the IMRT and VMAT treatment plans were generated. Plan comparison was done in terms of OAR dose, dose homogeneity index (HI), dose conformity index (CI), target coverage, low isodose volumes, monitor units (MUs), and treatment time.Results: The VMAT showed better sparing of “parotids minus planning target volume (PTV)”, spinal cord and head of femur as compared to the IMRT. The lung V40 for VMAT was lower, whereas the lung V10, contralateral lung mean dose, contralateral breast mean dose and mean body dose were lower with IMRT for chest wall cases. Both the VMAT and IMRT achieved comparable HI except for the brain site, where IMRT scored over VMAT. The CI achieved by the IMRT and VMAT were similar except for chest wall cases, whereas the VMAT achieved better dose conformity. The target coverage was comparable with both the plans. The VMAT clearly scored over IMRT in terms of average MUs (486 versus 812 respectively) and average treatment time (2.54 minutes versus 5.54 minutes) per treatment session. Conclusion: The VMAT (RapidArc) has a potential to generate treatment plans for various anatomical sites which are comparable with the corresponding IMRT plans in terms of OAR sparing and plan quality parameters. The VMAT significantly reduces treatment time as compared to the IMRT, thus VMAT can increase the throughput of a busy radiotherapy department.</p

    Comparative dosimetric analysis of IMRT and VMAT (RapidArc) in brain, head and neck, breast and prostate malignancies

    Get PDF
    Purpose: Intensity modulated radiotherapy (IMRT) in the recent past has established itself as a gold standard for organs at risk (OAR) sparing, target coverage and dose conformity. With the advent of a rotational treatment technology such as volumetric modulated arc therapy (VMAT), an inter-comparison is warranted to address the advantages and disadvantages of each technique. Methods: Twenty patients were selected retrospectively from our patient database. Sites included were brain, head and neck, chest wall, and prostate, with five patients for each site. For all the selected patients, both the IMRT and VMAT treatment plans were generated. Plan comparison was done in terms of OAR dose, dose homogeneity index (HI), dose conformity index (CI), target coverage, low isodose volumes, monitor units (MUs), and treatment time.Results: The VMAT showed better sparing of “parotids minus planning target volume (PTV)”, spinal cord and head of femur as compared to the IMRT. The lung V40 for VMAT was lower, whereas the lung V10, contralateral lung mean dose, contralateral breast mean dose and mean body dose were lower with IMRT for chest wall cases. Both the VMAT and IMRT achieved comparable HI except for the brain site, where IMRT scored over VMAT. The CI achieved by the IMRT and VMAT were similar except for chest wall cases, whereas the VMAT achieved better dose conformity. The target coverage was comparable with both the plans. The VMAT clearly scored over IMRT in terms of average MUs (486 versus 812 respectively) and average treatment time (2.54 minutes versus 5.54 minutes) per treatment session. Conclusion: The VMAT (RapidArc) has a potential to generate treatment plans for various anatomical sites which are comparable with the corresponding IMRT plans in terms of OAR sparing and plan quality parameters. The VMAT significantly reduces treatment time as compared to the IMRT, thus VMAT can increase the throughput of a busy radiotherapy department

    COVID-19 vaccines portray the bright side of human creativity, but it means nothing until they prove their worth: A Study on Seroconversion after the first Dose of Covishield vaccine in central Kerala

    No full text
    Background: COVID-19 vaccines, we believe, have come to rescue us from the clutches of the dreaded severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). With rapid ongoing mutations, it is difficult to predict the effectiveness of seroconversion following vaccination. This study aims to find out the proportion of people with seroconversion following first dose of Covishield vaccine. Methods: Randomly selected health-care workers were followed up for SARS-CoV-2 immunoglobulin G (IgG) antibodies between 28 and 42 days after receiving their first vaccine dose. The VITROS SARS-CoV-2 IgG test (Ortho-Clinical Diagnostics, USA) with 100% specificity and > 90% sensitivity was used to assess seroconversion. Results: The first dose of vaccine induced seroconversion in 91.7% of beneficiaries. Nearly one-third (30.2%) of them had high antibody titers, and it showed a significant association with female gender (9.6 ± 5.5 vs. 7.6 ± 5.6) and younger age (P = 0.008). In addition, those with previous COVID infection showed a more robust immune response when compared to others (P = 0.001). Conclusion: Seroconversion rate of more than 90% offers a promising hope toward successful pandemic control. In the current scenario, the inability to attain the targeted coverage due to an upsurge in vaccine hesitancy, compounded with only lower proportion of seroconversion in elderly, faster rollout of the vaccines without any age limit, will help achieve the herd threshold more rapidly

    Radiotherapy for large cutaneous angiosarcoma of face with RapidArc (VMAT)

    No full text
    Angiosarcoma is a rare malignancy of vascular origin. It can affect any part of the body, head and neck region being probably the most common site of diagnosis. We present here a case of Angiosarcoma of face in a 67-year-old elderly gentleman who was treated with RapidArc – volumetric modulated arc therapy (VMAT) for recurrence after surgery, radiotherapy and chemotherapy. As an alternative to Electron Beam Therapy, RapidArc with skin bolus can be considered for large complex shaped targets with irregular surface and tissue inhomogeneity. RapidArc plan can achieve adequate target coverage with acceptable dose homogeneity and conformity.</p
    corecore