254 research outputs found
Study of the surface microrelief of copper nanoparticles by the method of scanning probe microscopy
This work was supported by grants from the RFBR № 17-07-00407-а and № 17-32-50137-mol_nr
Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm
thickness carbon targets have been studied with high-resolution silicon
microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of
the scattering angle between data and GEANT4 simulation shows excellent
agreement in the core of the distributions leaving some residual disagreement
in the tails.Comment: 14 pages, 16 figures. Updated to match published versio
The UA9 experimental layout
The UA9 experimental equipment was installed in the CERN-SPS in March '09
with the aim of investigating crystal assisted collimation in coasting mode.
Its basic layout comprises silicon bent crystals acting as primary
collimators mounted inside two vacuum vessels. A movable 60 cm long block of
tungsten located downstream at about 90 degrees phase advance intercepts the
deflected beam.
Scintillators, Gas Electron Multiplier chambers and other beam loss monitors
measure nuclear loss rates induced by the interaction of the beam halo in the
crystal. Roman pots are installed in the path of the deflected particles and
are equipped with a Medipix detector to reconstruct the transverse distribution
of the impinging beam. Finally UA9 takes advantage of an LHC-collimator
prototype installed close to the Roman pot to help in setting the beam
conditions and to analyze the efficiency to deflect the beam. This paper
describes in details the hardware installed to study the crystal collimation
during 2010.Comment: 15pages, 11 figure, submitted to JINS
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
Experimental study of the radiation emitted by 180-GeV/c electrons and positrons volume-reflected in a bent crystal
The radiation emitted by 180-GeV/c volume-reflected electrons and positrons impinging on a bent crystal has been measured by the H8RD22 Collaboration on the H8 beamline at the CERN SPS. A dedicated spectrometer has been developed to measure high-energy photon spectra (up to similar to 100 GeV) under volume reflection: photon and charged particle beams have been separated by a bending magnet and leptons were detected and tagged by microstrip silicon detectors and a Pb-scintillator sampling calorimeter. A comparison between the experimental and analytical data for the amorphous and volume-reflection cases is presented and the differences are discussed
Double volume reflection of a proton beam by a sequence of two bent crystals
The doubling of the angle of beam deflection due to volume reflection of protons by a sequence of two bent silicon crystals was experimentally observed at the 400 GeV proton beam of the CERN SPS. A similar sequence of short bent crystals can be used as an efficient primary collimator for the Large Hadron Collider
- …