116 research outputs found

    Femoral Neck Anteversion: Values, Development, Measurement, Common Problems

    Get PDF
    The femoral neck anteversion angle is an important factor for hip stability and normal walking. It is multifactoral result of evolution, heredity, fetal development, intrauterine position, and mechanical forces. Abnormal FNA sometimes can be associated with many clinical problems ranging from harmless intoeing gait in the early childhood, to disabling osteoarthritis of the hip and the knee in the adults. In most cases is associated with minor functional problems in children during growth, but cause a concern in parents for children future. The child must be examined carefully and an accurate diagnosis must be established. The most important part of care is observation of the children. If abnormal femoral neck anteversion produces severe functional disability, derotational osteotomy should be done, but delayed until late childhoo

    Vertebroplasty – High Viscosity Cement versus Low Viscosity Cement

    Get PDF
    The patients with intensive pain caused by the vertebra body fracture were treated by application of low viscosity cement (LVC),(Vertebroplastic, DePuy) and high viscosity cement (HVC),(Confidence, DePuy,) into the body, by means of diascopy through unilateral transpendicular approach. Application of LVC was made in 75 patients, on 109 vertebrae, and HVC was applied in 12 patients on 14 vertebrae. Application of LVC was performed on 48 thoracic and 61 lumbar vertebrae and 5 thoracic and 9 lumbar vertebrae were stabilized with HVC. 43 patients were treated for malignancy and in 38 for osteoporosis. For LVC, preoperative VAS score was 8.32 and 2.23 (p<0.00001) 24 hours after surgery, and it remained stable 3 month later. For HVC, preoperative VAS score was 7.99 and it was 2.5 (p<0.00001) 24 hours after surgery and 3 months later. In the group of patients treated with LVC, there was 1 serious complication, a paraparesis caused by the leakage of cement into the spinal canal, which was partially recovered after decompression and rehabilitation treatment and 2 superificial infections with S. epidermidis which were cured by means of antibiotics. In 32 vertebrae (32) cement leakage extra ossal, either into vein plexus or intradiscal during surgery were noticed. When HVC was applied, intradiscal leakage occurred in one case onl (8%). By means od Wilcoxon paired test a significant difference was found between the preoperative VAS, and the values immediately after surgery and 3 months later (Z=7.52, p<0.00001) when LVC was applied., and with HVC it was (Z=3.04, p<0.00001), which indicates that the fast achieved pain reduction remained stable during the 3 month follow-up. The vertebroplasty is a safe and efficient surgical method in treatment of compressive vertebrae fractures which do not react to the conventional method of treatment. This method, when HVC is applied, shows significantly less complications related to cement leakage

    THz packaging solution for low cost si-based 40 Gb/s wireless link system

    Get PDF
    This paper presents an innovative low-cost transmitter solution aimed at improving telecommunication networks capacities in order to support the massive data traffic growth. Sub-THz frequencies > 200 GHz are considered to target at least 40 Gb/s. The proposed transmitter consists of a Silicon Photonic integrated sub-THz source and an industrial antenna integrated in HDI organic packaging substrate. As these components were experimentally evaluated, a real-time error free wireless data transmission of 10 Gb/s was successfully achieved and an antenna gain of 5.5 dBi was measured in the broadside direction from 220 GHz to 240 GHz (8.7% relative bandwidth). With the addition of a low-cost dielectric lens, a gain of 17 dBi was reached.info:eu-repo/semantics/acceptedVersio

    Field Experience on Indoor Radon, Thoron and Their Progenies with Solid-State Detectors in a Survey of Kosovo and Metohija (Balkan Region)

    Full text link
    Since 1996/97, indoor radon has been measured in scattered locations around Kosovo. In the most recent campaign, apart from radon, thoron and Rn and Tn progenies have also been measured. The current survey involves 48 houses, in which different detectors have been deployed side-by-side in one room, in order to measure indoor radon and thoron gas with RADUET devices based on CR-39 detectors (analysed by Japanese collaborators) and with direct thoron and radon progeny sensor (DTPS and DRPS) devices based on LR-115 detectors (analysed by collaborators from India). Estimated arithmetic mean values of concentrations in 48 houses are 122 Bq m(-3) for radon and 136 Bq m(-3) for thoron. Those for equilibrium equivalent radon concentration and equilibrium equivalent thoron concentration based on measurements in 48 houses are 40 and 2.1 Bq m(-3), respectively. The arithmetic mean value of the equilibrium factor is estimated to be 0.50 +/- 0.23 for radon and 0.037 +/- 0.041 for thoron. The preliminary results of these measurements are reported, particularly regarding DTPS and DRPS being set up in real field conditions for the first time in the Balkan region. The results are to be understood under the caveat of open questions related to measurement protocols which yield reproducible and representative results, and to quality assurance of Tn and Rn/Tn progeny measurements in general, some of which are discussed.International Symposium on Natural Radiation Exposure and Low-dose Radiation Epidemiological Studies, Feb 29-Mar 03, 2012, Hirosaki Univ Inst Radiat Med, Hirosaki, Japa
    corecore