Tension perpendicular to grain strength of wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C)
Recent experimental tests carried out on structural timber members have highlighted the importance of tension perpendicular to grain strength, particularly in beams with holes and notches, in connection regions, in curved beams, and in post-tensioned timber frames. Innovative engineered wood products such as Cross Banded Laminated Veneer Lumber (LVL-C) have been introduced into the market specifically to improve the perpendicular to grain properties of normal Laminated Veneer Lumber (LVL). This paper reports on tests that were performed at the University of Canterbury using specimens of sawn timber Radiata Pine, LVL and LVL-C. The perpendicular to grain tension strengths of LVL was generally lower than those for sawn timber, but the LVL-C showed a significantly improved strength. The paper also compares the experimental results with strengths predicted using both coupled elastic Finite Element Method (FEM) and Linear Elastic Fracture Mechanics (LEFM) models. These models were found to predict the average strength with reasonable accuracy. © 2011 Taylor & Francis Group, London
Composite WoodâConcrete Structural Floor System with Horizontal Connectors
The concept of horizontal shear connection utilization on woodâconcrete beams intends to be an alternative connection detail for composite woodâconcrete decks. The volume of sawn-wood is over three times more expensive than concrete, in Brazil. In order to be competitive in the Brazilian market we need a composite deck with the least amount of wood and a simple and inexpensive connection detail. This research project uses medium to high density tropical hardwoods managed from the Brazilian Amazon region and construction steel rods. The beams studied are composed of a bottom layer of staggered wood boards and a top layer of concrete. The wood members are laterally nailed together to form a wide beam, and horizontal rebar connectors are installed before the concrete layer is applied on top. Two sets of woodâconcrete layered beams with horizontal rebar connectors (6 and 8) were tested in third-point loading flexural bending. The initial results reveal medium composite efficiency for the beams tested. An improvement on the previously conceived connection detail (set with six connectors) for the composite woodâconcrete structural floor system was achieved by the set with eight connectors. The new layout of the horizontal rebar connectors added higher composite efficiency for the beams tested. Further analysis with advanced rigorous numerical Finite Element Modeling is suggested to optimize the connection parameters. Composite woodâconcrete decks can attend a large demand for pedestrian bridges, as well as residential and commercial slabs in the Brazilian Amazon. © 2014, The Author(s)
On the design of timber bolted connections subjected to fire
Paper 121Current research at the University of Canterbury is investigating the application of Johansenâs yield
equations to the prediction of the failure strength of bolted connections in fire conditions. A series
of single bolted connections using steel side plates have been heated at constant temperature for
several hours, then loaded to failure. The failure loads have been used to determine the embedment
strength of the joints at various temperatures over a range of temperatures from ambient to 300°C.
These temperature-dependent embedment strengths have also been used in the Johansenâs equations
for wood-steel-wood and wood-wood-wood connections and compared with the results for single
bolted connections tested over a range of constant temperatures. Comparisons have also been made
with the results of several similar connections tested in fire conditions and show considerable
promise for predicting failure of such joints
Feasibility and Detailing of Post-tensioned Timber Buildings for Seismic Areas
Paper 53This paper describes the structural design and selection of construction
detailing for low-rise multi-storey timber buildings using a new and exciting structural
timber system. This system, originally developed for use with pre-cast concrete,
combines the use of un-bonded post-tensioning techniques and additional sources of
energy dissipation. This system eliminates residual displacement, while greatly reducing
the damage to structural members during a significant seismic event. The paper shows
how this new structural system can be used with large size structural timber members
manufactured from laminated veneer lumber (LVL) or glulam timber, for use in multistorey
buildings, with lateral load resistance provided by post-tensioned structural timber
frames or walls, separately or in combination.
An extensive on-going research program at the University of Canterbury, New Zealand
has tested a wide range of beam-to-column, wall-to-foundation and column-to-foundation
connections under simulated seismic loading, all giving excellent results.
As part of this contribution, a case study of the design methods, construction options, cost
and feasibility of a six storey timber office building in a moderate seismic area is carried
out. The structural design of this building allowed investigation of different methods of
structural analysis, and the development of many construction and connection details
offering feasibility of rapid construction. Total building cost was evaluated and compared
to equivalent steel and reinforced concrete options
Long-term behavior of timber-concrete composite beams. II: Numerical analysis and simplified evaluation
http://dx.doi.org/10.1061/(ASCE)0733-9445(2006)132:1(23)This second part of two companion papers investigates the contribution of different rheological phenomena and thermohygrometric variations on long-term behavior of timberâconcrete composite beams (TCCs) in outdoor conditions. The numerical algorithm presented and validated against two experimental tests in the first part is employed with this aim. Such a model fully considers all rheological phenomena and, therefore, leads to rigorous solutions. Effects on the beam response include the creep and mechanosorptive creep of both timber and connection, along with concrete creep and shrinkage, and may markedly increase the elastic deflection due to live load. The inelastic strains due to yearly and daily variations of environmental conditions (temperature and relative humidity) produce an important fluctuation of the deflection. A simplified method, which is suitable for practical design of TCCs under long-term loading, is at last proposed. The effects of load, concrete shrinkage, and inelastic strains due to environmental variations are evaluated one by one using approximate formulas and are then superimposed. Creep and mechanosorptive creep are taken into account by adopting modified elastic moduli. The reliability of the proposed method is checked by way of some comparisons with numerical results. The applicability for the case of TCCs in heated indoor conditions is also discussed
Damage classification after the 2009 L'Aquila earthquake using multinomial logistic regression and neural networks
Post-earthquake surveys represent a fundamental tool for managing the emergency phase after a strong earthquake. In Italy, the evaluation of the post-earthquake functionality of ordinary buildings is based on the AeDES forms (AgibilitaÌ e Danno nell'Emergenza Sismica, or equivalently, Rapid Post-Earthquake Damage evaluation forms). This form includes information on the building and records of the observed damage classified according to type and intensity in 60 subclasses. Based on the observed damage and expert judgment, the buildings are clustered into six risk classes, from A to F. The assigned class is used to calculate the maximum economic reimbursement owed for the reconstruction or repair of the building. However, often the cluster assignment is not entirely objective due to the inherent responsibility associated with a less conservative assessment. This paper uses the data from the 2009 L'Aquila earthquake to develop classification models based on multinomial logistic regression (MLR) and artificial neural networks (ANN) calibrated with data theoretically less influenced by personal biases. The proposed models, particularly the MLR, are intended to support the decision-making of the evaluation team in future updates of the AeDES forms. This approach cannot substitute expert evaluation, which is always necessary for complex scenarios but may mitigate the impact of subjectivity and can provide an indication of the expected outcome of the survey
Buckling capacity model for timber screws loaded in compression: Experimental, analytical and FE investigations
This paper investigates the buckling of screws loaded in compression inserted into timber members. Screws are often used as a reinforcement in timber structures. However, under compression forces, they are prone to axial buckling. The current model for the screw buckling, enclosed in the EC5 proposal, is based on the general framework of EC3 for the instability of compressed steel members. The main shortcomings of the current formulation for the buckling of screws are the following. (1) The analytical expression for calculating the theoretical buckling load does not follow the observed modes. (2) Due to the need for dedicated studies, the value of the imperfection coefficient is arbitrarily chosen. This paper fills the above gaps. Firstly, a simple analytical expression for predicting the buckling of screws is proposed and validated against experimental and finite element (FE) findings. Furthermore, the formulation adopts a more accurate expression for lateral deformation based on experimental observation. Secondly, a FE model calibrated on experimental tests is used to estimate the defect coefficients of the instability curves as a function of the amplitude of the geometric defects of the screw, expressed as a fraction of its length. Finally, a Markov chain Monte Carlo analysis is carried out to simulate the capacity of screws with different sizes, assuming the uncertainty of all input parameters sampled from suitable probability distributions. The results are used to validate the proposed deterministic capacity model and estimate the uncertainty factors of the design equation
Charring rate for fire exposed X-Lam
Design of timber structures has been outlined in Eurocode 5. Notional charring rate for softwood and hardwood timber is given. For the performance of X-LAM panels in fire, only little information on charring is available and whether the fire behaviour of X-LAM is similar to homogenous timber panels has not yet been systematically analysed. This paper presents an overview of fire performance of X-LAM and evaluation of its resistance to elevated temperature as an element of structure in comparison to homogeneous timber panels. Numerical study has been carried out based on available experimental results. Charring rates for X-LAM panels obtained from experimental results are compared with those obtained from Eurocode 5 and proposed simplified model
The pi -> pi pi process in nuclei and the restoration of chiral symmetry
The results of an extensive campaign of measurements of the pi -> pi pi
process in the nucleon and nuclei at intermediate energies are presented. The
measurements were motivated by the study of strong pi pi correlations in
nuclei. The analysis relies on the composite ratio C_{pi pi}^A, which accounts
for the clear effect of the nuclear medium on the (pi pi) system. The
comparison of the C_{pi pi}^A distributions for the (pi pi)_{I=J=0} and (pi
pi)_{I=0,J=2} systems to the model predictions indicates that the C_{pi pi}^A
behavior in proximity of the 2m_pi threshold is explainable through the partial
restoration of chiral symmetry in nuclei.Comment: accepted for publication in Nucl. Phys.
Low-Noise Ku-Band Receiver Frontend with Switchable SIW Filters for Cubesat Applications
This paper proposes a low-noise receiver frontend
for nanosatellite and Cubesat platforms. The frontend is composed by a Low-Noise Amplifier (LNA) and two Substrate
Integrated Waveguide (SIW) filters, providing a frequency reconfigurability to the system. The two filters operate in the 13 and in
the 14 GHz uplink bands, and are selected by means of a pair of
solid-state SPDT switches. As a results, 15.5 dB gain with 2.4 dB
noise figure for the 13 GHz configuration and 17.8 dB gain with
2.3 dB noise figure for the 14 GHz configuration are obtained.
This work is important since demonstrates a low-cost solution
for satellite radio apparatuses based on commercial components
on a standard PCB
- âŠ