11 research outputs found
Benestent II: Back to the future
It has been shown repeatedly in animal and clinical studies that heparin coating reduces thrombotic complications of several surfaces in contact with flowing blood. The demonstration that implantation of heparin-coated coronary stents is also effective in prevention of subacute thrombotic occlusion in a pig model offers the persp
Evolution of coronary atherosclerosis in patients with mild coronary artery disease studied by serial quantitative coronary angiography at 2 and 4 years follow up
AIMS: Angiographic studies on the natural course of both focal and diffuse coronary atherosclerosis have not been performed before, but can both be assessed by quantitative coronary angiography. The objective of this study was to describe the natural course of focal and diffuse coronary atherosclerosis over time. METHODS AND RESULTS: In 129 patients with mild coronary artery disease, but not on lipid-lowering medication, three coronary angiograms were made each 2 years apart. Nine hundred and sixty five angiographically diseased and non-diseased segments were analysed by quantitative coronary angiography. Mean lumen diameter and minimal lumen diameter were used as measures of diffuse and focal coronary atherosclerosis. Mean lumen diameter and minimum lumen diameter decreased by 0.02 and 0.03 mm per year. The rate of progression was similar in the angiographically non-diseased, as in the mildly and moderately diseased segments. Progression of diffuse coronary atherosclerosis was largest in severely stenosed lesions (percentage diameter stenosis > or = 50%) and in the right coronary artery with a loss of 0.19 mm and 0.16 mm in mean lumen diameter. Progression of focal disease was most prominent in new and mild lesions and the right coronary artery, with a decrease in minimum lumen diameter of 0.34 mm and 0.22 mm. In most subgroups, progression occurred gradually over time. On a per segment level, progression and the occurrence of new lesions occurred in 4.4% and 4.2%. Regression and disappearance of a lesions was found in 2.3% and 1.9%. On a per patient level, 36% were progressors, 12% had a mixed response, 36% were stable, and 16% were regressors. CONCLUSION: Diffuse and focal coronary atherosclerosis progressed at the same rate in the first and second 2 years in stenosed and non-stenosed segments. The rate of coronary atherosclerosis progression was small, but was higher for focal than for diffuse disease. A minority of lesions progressed and spontaneous regression was rare
High-fidelity translesional pressure gradients during percutaneous transluminal coroanry angioplasty: correlation with quantitative coronary angiography
A fiberoptic pressure sensor mounted on an 0.018-inch guidewire (Pressure Guide) was used to measure the transstenotic pressure gradient in 30 patients undergoing percutaneous transluminal coronary angioplasty (PTCA) with lesions considered suitable for quantitative coronary angiographic (QCA) assessment. The aim of the study was to correlate pressure gradients with parameters obtained with QCA. After intracoronary injection of 125 micrograms of nitroglycerin, multiple angiographic views were taken of the lesion. The Pressure Guide fiberoptic sensor was then positioned distal to the stenosis and the pressure gradients were recorded before and after PTCA. There was a significant correlation between mean pressure gradients (delta P) and percent diameter stenosis (r = 0.73; p < 0.001) and absolute stenosis diameter (r = -0.67; p < 0.001) and with percent area stenosis (r = 0.69; p < 0.001) and absolute stenosis area (r = -0.63; p < 0.001). The closest relationship, though, wa
Does the new angiotensin converting enzyme inhibitor cilazapril prevent restenosis after percutaneous transluminal coronary angioplasty? Results of the MERCATOR study: a multicenter, randomized, double-blind placebo-controlled trial
BACKGROUND. Cilazapril is a novel angiotensin converting enzyme inhibitor with antiproliferative effects in the rat model after balloon injury. METHODS AND RESULTS. We conducted a randomized, double-blind placebo-controlled trial to assess the effect of cilazapril in angiographic restenosis prevention after percutaneous transluminal coronary angioplasty (PTCA). Patients received cilazapril 2.5 mg in the evening after successful PTCA and 5 mg b.i.d. for 6 months or matched placebo. In addition, all patients received aspirin for 6 months. Coronary angiograms before PTCA, after PTCA, and at 6-month follow-up were quantitatively analyzed. In 94% of 735 recruited patients, PTCA was successful and all inclusion and exclusion criteria were met. For the per-protocol analysis, quantitative angiography after PTCA and at follow-up was available in 595 patients who complied with the treatment regimen (309 control, 286 cilazapril). The mean difference in minimal coronary lumen diameter between post-PTCA and follow-up angiogram (primary end point) was -0.29 +/- 0.49 mm in the control group and - 0.27 +/- 0.51 mm in the cilazapril group. Clinical events during 6- month follow-up, analyzed on an intention-to-treat basis, were ranked according to the most serious clinical event ranging from death (control, two; cilazapril, three), nonfatal myocardial infarction (control, eight; cilazapril, 5), coronary revascularization (control, 51; cilazapril, 53), or recurrent angina requiring medical therapy (control, 67; cilazapril, 68) to none of the above (control, 224; cilazapril, 212). There were no significant differences in ranking. CONCLUSIONS. Long-term angiotensin converting enzyme inhibition with cilazapril in a dose of 5 mg b.i.d. does not prevent restenosis and does not favorably influence the overall clinical outcome after PTCA
Intracoronary pressure and flow velocity with sensor-tip guidewires: a new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions
The use of miniaturized pressure and velocity sensors mounted on angioplasty guidewires allows the simultaneous measurement of coronary blood flow velocity and transstenotic pressure gradient, 2 parameters that, combined, should perfectly characterize stenosis hemodynamics. The aim of this article is assessment of the changes in coronary blood flow velocity observed with a Doppler-tipped angioplasty guidewire in 35 patients undergoing balloon angioplasty. We also report our initial experience in 16 patients with the combined use of sensor-tip pressure and Doppler guidewires, and we discuss the application of new methodologic approaches for the study of the coronary circulation allowed by these techniques, such as the instantaneous assessment of the flow velocity/pressure and pressure gradient/flow velocity relations. Before and after angioplasty, flow velocity measurements were obtained distal to the stenosis, both in baseline conditions and after intracoronary injection of 8-12.5 mg of papaverine. The Doppler guidewire was left in place during the dilation procedure and the Doppler signal was continuously recorded during balloon inflation and after deflation to monitor the development of collateral flow, the restoration of flow after balloon deflation, the phase of postocclusive reactive hyperemia, and, incidently, the develo
Therapeutic dissection after successful coronary balloon angioplasty: no influence on restenosis or on clinical outcome in 693 patients. The MERCATOR Study Group (Multicenter European Research Trial with Cilazapril after Angioplasty to prevent Transluminal Coronary Obstruction and Restenosis)
OBJECTIVES: The objective of this study was to examine the relation between an angiographically visible coronary dissection immediately after successful coronary balloon angioplasty and a subsequent restenosis and long-term clinical outcome. BACKGROUND. The study population comprised all 693 patients who participated in the MERCATOR trial (randomized, double-blind, placebo-controlled restenosis prevention trial of cilazapril, 5 mg two times a day). METHODS. Cineangiographic films were processed and analyzed at a central angiographic core laboratory, without knowledge of clinical data, with use of an automated interpolated edge detection technique. Dissection was judged according to the National Heart, Lung, and Blood Institute classification. Angiographic follow-up was obtained in 94% of patients with 778 lesions. Two approaches were used to assess the restenosis phenomenon: 1) categoric, using the traditional cutoff criterion of greater than 50% diameter stenosis at follow-up, and 2) continuous, defined as absolute change in minimal lumen diameter (mm) between the postcoronary angioplasty and follow-up, adjusted for the vessel size (relative loss). Clinical outcome was ranked according to the most serious adverse clinical event per patient during the 6-month follow-up period, ranging from death, nonfatal myocardial infarction, coronary revascularization and recurrent angina requiring medical therapy to none of these. RESULTS. Dissection was present in 247 (32%) of the 778 dilated lesions. The restenosis rate was 29% in lesions with and 30% in lesions without dissection (relative risk 0.97; 95% confidence interval 0.77 to 1.23). The relative loss in both groups was 0.10 (mean difference 0; 95% confidence interval -0.03 to 0.03). Clinical outcome ranged from death in 4 patients (0.9%) without dissection and 1 patient (0.4%) with dissection; nonfatal myocardial infarction in 4 (0.9%) without and 8 (3.2%) with dissection; coronary revascularization in 73 (16.6%) without and 32 (12.7%) with dissection; recurrent angina requiring medical therapy in 88 (20%) without and 47 (18.7%) with dissection to no serious adverse event in 272 (61.7%) without and 114 (65.1%) with dissection. CONCLUSIONS. These data indicate that a successfully dilated coronary lesion with an angiographically visible dissection is no more likely to develop restenosis, and is not associated with a worse clinical outcome, at 6-month follow-up than is a dilated lesion without visible dissection on the post-balloon angioplasty angiogram
Reduction in Thrombotic Events With Heparin-Coated Palmaz-Schatz Stents in Normal Porcine Coronary Arteries.
Background The use of stents improves the result after balloon coronary angioplasty. Thrombogenicity of stents is, however, a concern. In the present study, we compared stents with an antithrombotic coating with regular stents.
Methods and Results Regular stents were placed in coronary arteries of pigs receiving no aspirin (group 1; n=8) or aspirin over 4 weeks (group 2, n=10) or 12 weeks (group 3, n=9). Stents coated with heparin (antithrombin III uptake, 5 pmol/stent) were placed in 7 pigs that did not receive aspirin (group 4). The other animals received aspirin and coated stents with a heparin activity of 12 pmol antithrombin III/stent (group 5, n=10) or 20 pmol/stent (group 6, n=10; group 7, n=10). Quantitative arteriography was performed at implantation and after 4 (groups 1, 2, and 4 through 6) or 12 weeks (groups 3 and 7). In an additional 5 animals, five regular and five coated stents (20 pmol/stent) were placed and explanted after 5 days for examination of the early responses to the implants. Thrombotic occlusion of the regular stent occurred in 9 of 27 in groups 1 through 3. However, in 0 of 30 of the animals receiving high-activity heparin-coated stents (groups 5 through 7), thrombotic stent occlusion was observed (P<.001). Histological analysis at 4 weeks showed that the neointima in group 6 was thicker compared with its control group 2 (259±104 and 117±36 µm, P<.01), but at 12 weeks the thickness was similar (152±61 and 198±49 µm, respectively). Comparison at 5 days suggested delayed endothelialization of the coating
Evaluation of Ketanserin in the Prevention of Restenosis After Percutaneous Transluminal Coronary Angioplasty
BACKGROUND. Ketanserin is a serotonin S2-receptor antagonist that inhibits the platelet activation and vasoconstriction induced by serotonin and also inhibits the mitogenic effect of serotonin on vascular smooth muscle cells. METHODS AND RESULTS. We conducted a randomized, double blind