527 research outputs found

    The inaugural australian centre for hepatitis virology public panel discussion on viral hepatitis research—lessons in scientific community outreach

    Full text link
    Viral hepatitis remains one of the most significant health issues globally, directly responsible for over 1 million deaths each year and affecting almost 300 million people around the world. Scientific research in recent decades has brought about improvements in the lives of people living with chronic viral hepatitis. On the 29 July 2021, the Australian Centre for Hepatitis Virology (ACHV) for the first time held a public educational forum for the general public. The main aim of this event was to inform the affected community about the importance of scientific research and give an overview of upcoming developments in the field. Here, we provide a detailed report of the panel discussion (including its organisation, execution, and lessons learned to incorporate into future events) and provide strategies that can be used by other scientific societies to hold similar events in their own communities

    Вища математика. Ч.1. Диференціальне числення у прикладах та задачах

    Get PDF
    Викладено набір теоретичних та практичних тестів з диференціального числення функції однієї та багатьох змінних. Докладні відповіді, вказівки, розв’язання типових завдань та достатня кількість прикладів для самостійної роботи дозволяють використовувати посібник для всіх видів занять

    The use of alfaxalone for short-term anesthesia can confound serum progesterone measurements in the common marmoset: a case report

    Get PDF
    Alfaxan® (alfaxalone) is a steroid general anesthetic widely used in veterinary medicine for induction and maintenance of anesthesia in several species. While the use of alfaxalone in veterinary practice has several benefits compared to the use of other anesthetic agents, the fact that it is derived from progesterone may confound the measurement of the latter in the blood of animals under alfaxalone treatment. In the present case study, we report the measurement of serum progesterone in an individual common marmoset (Callithrix jacchus) during five ovarian cycles in which luteolysis was induced by PGF2α. Blood samples were usually taken from the awake animal with the exception of the fifth cycle in which the sample was collected under alfaxalone anesthesia in connection with a tooth extraction. In contrast to the previous four cycles in which luteolysis resulted in the expected marked decrease in progesterone concentrations, the – apparent – progesterone level in the cycle under alfaxalone treatment remained unexpectedly high. Cross-reactivity of the non-specific antibody used in the progesterone assay with alfaxalone most likely explains this finding.</p

    Določanje benzodiazepinov v urinu preko benzofenonskih derivatov z uporabo tekočinske kromatografije sklopljene s tandemsko masno spektrometrijo

    Get PDF
    The aim of this study was to validate a new method for determining benzodiazepines in urine via their benzophenone derivatives, based on liquid chromatography-tandem mass spectrometry (LC-MS/MS). Selected benzodiazepines were analysed after acid hydrolysis of urine and extraction by ethyl acetate in the presence of an internal standard. Samples were analysed using electrospray ionization LC-MS/MS in a multiple reaction monitoring mode. The chromatographic run time on a reversed phase C18 analytical column was set for 9 min. This method was validated in 21 patients receiving methadone. Benzodiazepines intake was established in two out of three patients. LC-MS/MS results were also compared with the rapid immunoassay and the methods showed good agreement. However, in three cases benzodiazepines were detected by LC-MS/MS, but not by the immunoassay. The sensitivity of the developed LC-MS/MS method is comparable to or even higher than of previously reported methods, which makes it suitable as a confi rmatory method.Razvili smo selektivno in občutljivo metodo za določanje nekaterih benzodiazepinov v urinu preko določanja njihovih benzofenonov. Metoda temelji na tekočinski kromatografi ji, sklopljeni s tandemsko masno spektrometrijo (LC-MS/MS). Izbrane benzodiazepine smo analizirali po kisli hidrolizi urinskih vzorcev in ekstrakciji z etilacetatom v prisotnosti internega standarda. Vzorce smo analizirali z elektrorazprševalno ionizacijo z MRM načinom detekcije. Čas kromatografske ločbe na reverznofazni (C18) analitski koloni je bil 9 min. Metoda je bila validirana in preizkušena na 21 pacientih, ki so prejemali metadonsko terapijo. Pri dveh tretjinah primerov je bil vnos benzodiazepinov tudi potrjen. Vzorce smo testirali tudi s hitro imunokemijsko metodo in rezultate primerjali z rezultati pridobljenimi z LC-MS/MS metodo. Ugotovili smo dobro ujemanje med rezultati pridobljenimi z obe a metodama. Kljub temu smo v treh primerih določili prisotnost benzodiazepinov z LC-MS/MS metodo, ki je z imunokemijsko metodo nismo. Občutljivost razvite metode je primerljiva ali celo boljša od predhodno opisanih metod, zato jo lahko uporabimo kot potrditveno metodo

    Effects of end-stage osteoarthritis on markers of skeletal muscle Long INterspersed Element-1 activity

    Get PDF
    Objective: Long INterspersed Element-1 (L1) is an autonomous transposable element in the genome. L1 transcripts that are not reverse transcribed back into the genome can accumulate in the cytoplasm and activate an inflammatory response via the cyclic GMP-AMP (cGAS)-STING pathway. We examined skeletal muscle L1 markers as well as STING protein levels in 10 older individuals (63 ± 11 y, BMI= 30.2 ± 6.8 kg/m2) with end-stage osteoarthritis (OA) undergoing total hip (THA, n= 4) or knee (TKA, n= 6) arthroplasty versus 10 young, healthy comparators (Y, 22 ± 2 y, BMI= 23.2 ± 2.5 kg/m2). For OA, muscle was collected from surgical (SX) and contralateral (CTL) sides whereas single vastus lateralis samples were collected from Y. Results: L1 mRNA was higher in CTL and SX compared to Y (p \u3c 0.001 and p= 0.001, respectively). Protein expression was higher in SX versus Y for ORF1p (p= 0.002) and STING (p= 0.022). While these data are preliminary due to limited n-sizes and the lack of a BMI-matched younger control group, higher L1 mRNA expression, ORF1p and STING protein are evident in older versus younger adults. More research is needed to determine whether cGAS-STING signaling contributes to heightened muscle inflammation during aging and/or OA

    Анализ технологических параметров работы мембранных систем извлечения гелия из природного газа в процессе разработки газовых месторождений

    Get PDF
    Объектом исследования являются технологии выделения гелия из состава природного газа. Цель исследования – анализ технологических параметров работы мембранных систем выделения гелия из природного газа в процессе разработки газовых месторождений. В процессе исследования были рассмотрены существующие технологии выделения гелиевого концентрата, проанализированы основные производственные характеристики данных систем. Проведен анализ технологии мембранного выделения гелиевого концентрата и рассмотрены перспективы в использовании современных установок на основе мембранного разделения. В результате проведенного анализа был выявлен положительный эффект от внедрения модульных установок мембранного выделения гелиевого концентрата.The object of the research is technologies for the separation of helium from natural gas. The aim of the study is to analyze the technological parameters of the operation of membrane systems for the extraction of helium from natural gas during the development of gas fields. In the course of the research, the existing technologies for the separation of helium concentrate were considered, the main production characteristics of these systems were analyzed. The analysis of the technology of membrane separation of helium concentrate is carried out and the prospects for the use of modern installations based on membrane separation are considered

    A new panel of epitope mapped monoclonal antibodies recognising the prototypical tetraspanin CD81

    Get PDF
    Background: Tetraspanins are small transmembrane proteins, found in all higher eukaryotes, that compartmentalize cellular membranes through interactions with partner proteins. CD81 is a prototypical tetraspanin and contributes to numerous physiological and pathological processes, including acting as a critical entry receptor for hepatitis C virus (HCV). Antibody engagement of tetraspanins can induce a variety of effects, including actin cytoskeletal rearrangements, activation of MAPK-ERK signaling and cell migration. However, the epitope specificity of most anti-tetraspanin antibodies is not known, limiting mechanistic interpretation of these studies. Methods: We generated a panel of monoclonal antibodies (mAbs) specific for CD81 second extracellular domain (EC2) and performed detailed epitope mapping with a panel of CD81 mutants. All mAbs were screened for their ability to inhibit HCV infection and E2-CD81 association. Nanoscale distribution of cell surface CD81 was investigated by scanning electron microscopy. Results: The antibodies were classified in two epitope groups targeting opposing sides of EC2. We observed a wide range of anti-HCV potencies that were independent of their epitope grouping, but associated with their relative affinity for cell-surface expressed CD81. Scanning electron microscopy identified at least two populations of CD81; monodisperse and higher-order assemblies, consistent with tetraspanin-enriched microdomains. Conclusions: These novel antibodies provide well-characterised tools to investigate CD81 function, including HCV entry, and have the potential to provide insights into tetraspanin biology in general

    Measuring procedures for surface evaluation of additively manufactured powder bed-based polymer and metal parts

    Get PDF
    AbstractPowder bed-based additive manufacturing has become increasingly important for industrial applications. In the light of this, qualitative considerations such as the geometrical accuracy, the resulting mechanical properties, and the surface quality of additively manufactured parts must be taken into account. Optical measuring techniques such as confocal laser scanning microscopy, fringe projection and focus variation as well as profilometers are evaluated here, to determine the surface quality of powder bed-based manufactured parts. Even though these surface evaluation methods are established commercially, no standardized measuring procedure has yet been established. Within an experimental study the validity and accuracy of surface measurement methods are evaluated below, taking the limitations of each measurement system and the comparability of areal surface textures into account. The examinations are carried out with the powder materials EN-AW2024, Ti-6V-4Al and PA12, which are processed by electron beam melting, and laser beam melting of metals and polymers. Guidance for a consistent and comparable surface evaluation is thereby provided
    corecore