40 research outputs found

    Design and evaluation of an MRI-compatible linear motion stage.

    Get PDF
    PURPOSE: To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS: In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actuated with an ultrasonic motor. The stage can be positioned at arbitrary positions and orientations inside the scanner bore to move, push, or pull arbitrary phantoms. Using optical trackers, measuring microscopes, and navigators, the accuracy of the stage in motion control was evaluated. Also, the effect of the stage on image signal-to-noise ratio (SNR), artifacts, and B0 field homogeneity was evaluated. RESULTS: The error of the stage in reaching fixed positions was 0.025 ± 0.021 mm. In execution of dynamic motion profiles, the worst-case normalized root mean squared error was below 7% (for frequencies below 0.33 Hz). Experiments demonstrated that the stage did not introduce artifacts nor did it degrade the image SNR. The effect of the stage on the B0 field was less than 2 ppm. CONCLUSIONS: The results of the experiments indicate that the proposed system is MRI-compatible and can create reliable and reproducible motion that may be used for validation and assessment of motion related MRI applications

    Shape complexes: the intersection of label orderings and star convexity constraints in continuous max-flow medical image segmentation.

    Get PDF
    Optimization-based segmentation approaches deriving from discrete graph-cuts and continuous max-flow have become increasingly nuanced, allowing for topological and geometric constraints on the resulting segmentation while retaining global optimality. However, these two considerations, topological and geometric, have yet to be combined in a unified manner. The concept of shape complexes, which combine geodesic star convexity with extendable continuous max-flow solvers, is presented. These shape complexes allow more complicated shapes to be created through the use of multiple labels and super-labels, with geodesic star convexity governed by a topological ordering. These problems can be optimized using extendable continuous max-flow solvers. Previous approaches required computationally expensive coordinate system warping, which are ill-defined and ambiguous in the general case. These shape complexes are demonstrated in a set of synthetic images as well as vessel segmentation in ultrasound, valve segmentation in ultrasound, and atrial wall segmentation from contrast-enhanced CT. Shape complexes represent an extendable tool alongside other continuous max-flow methods that may be suitable for a wide range of medical image segmentation problems

    Stress-inducible phosphoprotein 1 has unique cochaperone activity during development and regulates cellular response to ischemia via the prion protein.

    Get PDF
    Stress-inducible phosphoprotein 1 (STI1) is part of the chaperone machinery, but it also functions as an extracellular ligand for the prion protein. However, the physiological relevance of these STI1 activities in vivo is unknown. Here, we show that in the absence of embryonic STI1, several Hsp90 client proteins are decreased by 50%, although Hsp90 levels are unaffected. Mutant STI1 mice showed increased caspase-3 activation and 50% impairment in cellular proliferation. Moreover, placental disruption and lack of cellular viability were linked to embryonic death by E10.5 in STI1-mutant mice. Rescue of embryonic lethality in these mutants, by transgenic expression of the STI1 gene, supported a unique role for STI1 during embryonic development. The response of STI1 haploinsufficient mice to cellular stress seemed compromised, and mutant mice showed increased vulnerability to ischemic insult. At the cellular level, ischemia increased the secretion of STI1 from wild-type astrocytes by 3-fold, whereas STI1 haploinsufficient mice secreted half as much STI1. Interesting, extracellular STI1 prevented ischemia-mediated neuronal death in a prion protein-dependent way. Our study reveals essential roles for intracellular and extracellular STI1 in cellular resilience

    Cardiovascular magnetic resonance phase contrast imaging

    Get PDF

    Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom

    No full text
    Purpose: To facilitate MRI-guided catheterization procedures, we present an MRI-compatible remote catheter navigation system that allows remote navigation of steerable catheters with 3 degrees of freedom. Methods: The system consists of a user interface (master), a robot (slave), and an ultrasonic motor control servomechanism. The interventionalist applies conventional motions (axial, radial and plunger manipulations) on an input catheter in the master unit; this user input is measured and used by the servomechanism to control a compact catheter manipulating robot, such that it replicates the interventionalist’s input motion on the patient catheter. The performance of the system was evaluated in terms of MRI compatibility (SNR and artifact), feasibility of remote navigation under real-time MRI guidance, and motion replication accuracy. Results: Real-time MRI experiments demonstrated that catheter was successfully navigated remotely to desired target references in all 3 degrees of freedom. The system had an absolute value error of \u3c 1 mm in axial catheter motion replication over 30 mm of travel and 3 ± 2 for radial catheter motion replication over 180 . The worst case SNR drop was observed to be \u3c 3 %; the robot did not introduce any artifacts in the MR images. Conclusion: An MRI-compatible compact remote catheter navigation system has been developed that allows remote navigation of steerable catheters with 3 degrees of freedom. The proposed system allows for safe and accurate remote catheter navigation, within conventional closed-bore scanners, without degrading MR image quality. ∘ ∘

    A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System

    No full text

    Cyclic Continuous Max-Flow: A Third Paradigm in Generating Local Phase Shift Maps in MRI

    No full text
    © 2017 IEEE. Sensitivity to phase deviations in MRI forms the basis of a variety of techniques, including magnetic susceptibility weighted imaging and chemical shift imaging. Current phase processing techniques fall into two families: those which process the complex image data with magnitude and phase coupled, and phase unwrapping-based techniques that first linearize the phase topology across the image. However, issues, such as low signal and the existence of phase poles, can lead both methods to experience error. Cyclic continuous max-flow (CCMF) phase processing uses primal-dual-variational optimization over a cylindrical manifold, which represent the inherent topology of phase images, increasing its robustness to these issues. CCMF represents a third distinct paradigm in phase processing, being the only technique equipped with the inherent topology of phase. CCMF is robust and efficient with at least comparable accuracy as the prior paradigms
    corecore