186 research outputs found

    Selection of massive bone allografts using shape-matching 3-dimensional registration

    Get PDF
    Background and purpose Massive bone allografts are used when surgery causes large segmental defects. Shape-matching is the primary criterion for selection of an allograft. The current selection method, based on 2-dimensional template comparison, is inefficient for 3-dimensional complex bones. We have analyzed a 3-dimensional (3-D) registration method to match the anatomy of the allograft with that of the recipient

    Infraglenoidal scapular notching in reverse total shoulder replacement: a prospective series of 60 cases and systematic review of the literature

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The impact of infraglenoidal scapular notching in reversed total shoulder arthroplasty (RTSA) is still controversially discussed. Our goal was to evaluate its potential influence on subjective shoulder stability and clinical outcome. We hypothesized that subjective instability and clinical outcome after implantation of RTSA correlates with objective scapular notching.</p> <p>Methods</p> <p>Sixty shoulders were assessed preoperatively and at minimum 2-year follow-up for active range of motion and by use of the Oxford instability score, Rowe score for instability, Constant score for pain, Constant shoulder score, DASH score. All shoulders were evaluated on anterior-posterior and axillary lateral radiographic views. These X-ray scans were classified twice by two orthopaedic surgeons with respect to infraglenoidal scapular notching according to the classification of Nerot. Notching was tested for correlation with clinical outcome scores to the evaluated notching.</p> <p>Results</p> <p>We found no significant correlation between infraglenoidal scapular notching and clinical outcomes after a mid-term follow-up from 24 to 60 months, but at the final follow-up of 60 months and more, we did see statistically significant, positive correlations between infraglenoidal scapular notching and the Constant pain score as well as active range of motion. At mean follow-up of 42 months (range from 24 to 96 months) we found no significant correlation between subjective instability and infraglenoidal scapular notching.</p> <p>Conclusions</p> <p>We conclude that patients' subjective impression on their shoulders' stability is not correlating with radiological signs of infraglenoidal scapular notching. Nevertheless clinical parameters are affected by infraglenoidal scapular notching, at least in the long term</p

    Prosthetic overhang is the most effective way to prevent scapular conflict in a reverse total shoulder prosthesis

    Get PDF
    Methods An average and a "worst case scenario" shape in A-P view in a 2-D computer model of a scapula was created, using data from 200 "normal" scapulae, so that the position of the glenoid and humeral component could be changed as well as design features such as depth of the polyethylene insert, the size of glenosphere, the position of the center of rotation, and downward glenoid inclination. The model calculated the maximum adduction (notch angle) in the scapular plane when the cup of the humeral component was in conflict with the scapula. Results A change in humeral neck shaft inclination from 155 degrees to 145 degrees gave a 10 degrees gain in notch angle. A change in cup depth from 8 mm to 5 mm gave a gain of 12 degrees. With no inferior prosthetic overhang, a lateralization of the center of rotation from 0 mm to 5 mm gained 16 degrees. With an inferior overhang of only 1 mm, no effect of lateralizing the center of rotation was noted. Downward glenoid inclination of 0 boolean OR to 10 boolean OR gained 10 degrees. A change in glenosphere radius from 18 mm to 21 mm gained 31 degrees due to the inferior overhang created by the increase in glenosphere. A prosthetic overhang to the bone from 0 mm to 5 mm gained 39 degrees. Interpretation Of all 6 solutions tested, the prosthetic overhang created the biggest gain in notch angle and this should be considered when designing the reverse arthroplasty and defining optimal surgical technique

    Clinical and functional outcomes of the saddle prosthesis

    Get PDF
    BACKGROUND:The implantation of a saddle prosthesis after resection of a pelvic tumor has been proposed as a simple method of reconstruction that provides good stability and reduces the surgical time, thus limits the onset of intraoperative complications. There are no studies in the literature of patients evaluated using gait analysis after being implanted with a saddle prosthesis. The present study is a retrospective case review aimed at illustrating long-term clinical and functional findings in tumor patients reconstructed with a saddle prosthesis. MATERIALS AND METHODS:A series of 15 patients who received pelvic reconstruction with a saddle prosthesis were retrospectively reviewed in terms of clinical, radiographic, and functional evaluations. Two patients were additionally assessed by gait analysis. RESULTS:Long-term functional follow-up was achieved in only 6 patients, and ranged from 97 to 167 months. Function was found to be rather impaired, as a mean of only 57 % of normal activity was restored. Gait analysis demonstrated that the implant had poor biomechanics, as characterized by very limited hip motion. CONCLUSIONS: Though the saddle prosthesis was proposed as advance in tumor-related pelvic surgery, the present study indicates that it yields unsatisfactory clinical and functional results due to both clinical complications and the poor biomechanics of the device. The use of a saddle prosthesis in tumor surgery did not provide satisfactory results in long-term follow-up. It is no longer implanted at our institute, and is currently considered a "salvage technique.

    Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis, in order to improve primary fixation of the component.</p> <p>Methods</p> <p>Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoid neck, the angle between the glenoid surface and the upper posterior column of the scapula and the angle between the major craneo-caudal glenoid axis and the base of the coracoid process and the upper posterior column.</p> <p>Results</p> <p>The anterior and posterior length of glenoid neck was classified into two groups named "short-neck" and "long-neck" with significant differences between them. The angle between the glenoid surface and the upper posterior column of the scapula was also classified into two different types: type I (mean 50°–52°) and type II (mean 62,50°–64°), with significant differences between them (p < 0,001). The angle between the major craneo-caudal glenoid axis and the base of the coracoid process averaged 18,25° while the angle with the upper posterior column of the scapula averaged 8°.</p> <p>Conclusion</p> <p>Scapular morphological variability advices for individual adjustments of glenoid component implantation in reversed total shoulder prosthesis. Three-dimensional computed tomography of the scapula constitutes an important tool when planning reversed prostheses implantation.</p

    Effects of low intensity pulsed ultrasound with and without increased cortical porosity on structural bone allograft incorporation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Though used for over a century, structural bone allografts suffer from a high rate of mechanical failure due to limited graft revitalization even after extended periods <it>in vivo</it>. Novel strategies that aim to improve graft incorporation are lacking but necessary to improve the long-term clinical outcome of patients receiving bone allografts. The current study evaluated the effect of low-intensity pulsed ultrasound (LIPUS), a potent exogenous biophysical stimulus used clinically to accelerate the course of fresh fracture healing, and longitudinal allograft perforations (LAP) as non-invasive therapies to improve revitalization of intercalary allografts in a sheep model.</p> <p>Methods</p> <p>Fifteen skeletally-mature ewes were assigned to five experimental groups based on allograft type and treatment: +CTL, -CTL, LIPUS, LAP, LIPUS+LAP. The +CTL animals (n = 3) received a tibial ostectomy with immediate replacement of the resected autologous graft. The -CTL group (n = 3) received fresh frozen ovine tibial allografts. The +CTL and -CTL groups did not receive LAP or LIPUS treatments. The LIPUS treatment group (n = 3), following grafting with fresh frozen ovine tibial allografts, received ultrasound stimulation for 20 minutes/day, 5 days/week, for the duration of the healing period. The LAP treatment group (n = 3) received fresh frozen ovine allografts with 500 μm longitudinal perforations that extended 10 mm into the graft. The LIPUS+LAP treatment group (n = 3) received both LIPUS and LAP interventions. All animals were humanely euthanized four months following graft transplantation for biomechanical and histological analysis.</p> <p>Results</p> <p>After four months of healing, daily LIPUS stimulation of the host-allograft junctions, alone or in combination with LAP, resulted in 30% increases in reconstruction stiffness, paralleled by significant increases (p < 0.001) in callus maturity and periosteal bridging across the host/allograft interfaces. Longitudinal perforations extending 10 mm into the proximal and distal endplates filled to varying degrees with new appositional bone and significantly accelerated revitalization of the allografts compared to controls.</p> <p>Conclusion</p> <p>The current study has demonstrated in a large animal model the potential of both LIPUS and LAP therapy to improve the degree of allograft incorporation. LAP may provide an option for increasing porosity, and thus potential <it>in vivo </it>osseous apposition and revitalization, without adversely affecting the structural integrity of the graft.</p

    Upstream ORF affects MYCN translation depending on exon 1b alternative splicing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The <it>MYCN </it>gene is transcribed into two major mRNAs: one full-length (<it>MYCN) </it>and one exon 1b-spliced (<it>MYCN</it><sup>Δ1<it>b</it></sup>) mRNA. But nothing is known about their respective ability to translate the MYCN protein.</p> <p>Methods</p> <p>Plasmids were prepared to enable translation from the upstream (uORF) and major ORF of the two <it>MYCN </it>transcripts. Translation was studied after transfection in neuroblastoma SH-EP cell line. Impact of the upstream AUG on translation was evaluated after directed mutagenesis. Functional study with the two <it>MYCN </it>mRNAs was conducted by a cell viability assay. Existence of a new protein encoded by the <it>MYCN</it><sup>Δ1<it>b </it></sup>uORF was explored by designing a rabbit polyclonal antibody against a specific epitope of this protein.</p> <p>Results</p> <p>Both are translated, but higher levels of protein were seen with <it>MYCN</it><sup>Δ1<it>b </it></sup>mRNA. An upstream ORF was shown to have positive cis-regulatory activity on translation from <it>MYCN </it>but not from <it>MYCN</it><sup>Δ1<it>b </it></sup>mRNA. In transfected SH-EP neuroblastoma cells, high MYCN dosage obtained with <it>MYCN</it><sup>Δ1<it>b </it></sup>mRNA translation induces an antiapoptotic effect after serum deprivation that was not observed with low MYCN expression obtained with <it>MYCN </it>mRNA. Here, we showed that MYCNOT: <it>MYCN </it>Overlap Transcript, a new protein of unknown function is translated from the upstream AUG of <it>MYCN</it><sup>Δ1<it>b </it></sup>mRNA.</p> <p>Conclusions</p> <p>Existence of upstream ORF in <it>MYCN </it>transcripts leads to a new level of MYCN regulation. The resulting MYCN dosage has a weak but significant anti-apoptotic activity after intrinsic apoptosis induction.</p
    corecore