203 research outputs found
Speckle Space-Time Covariance in High-Contrast Imaging
We introduce a new framework for point-spread function (PSF) subtraction
based on the spatio-temporal variation of speckle noise in high-contrast
imaging data where the sampling timescale is faster than the speckle evolution
timescale. One way that space-time covariance arises in the pupil is as
atmospheric layers translate across the telescope aperture and create small,
time-varying perturbations in the phase of the incoming wavefront. The
propagation of this field to the focal plane preserves some of that space-time
covariance. To utilize this covariance, our new approach uses a
Karhunen-Lo\'eve transform on an image sequence, as opposed to a set of single
reference images as in previous applications of Karhunen-Lo\'eve Image
Processing (KLIP) for high-contrast imaging. With the recent development of
photon-counting detectors, such as microwave kinetic inductance detectors
(MKIDs), this technique now has the potential to improve contrast when used as
a post-processing step. Preliminary testing on simulated data shows this
technique can improve contrast by at least 10-20% from the original image, with
significant potential for further improvement. For certain choices of
parameters, this algorithm may provide larger contrast gains than spatial-only
KLIP.Comment: Accepted to A
Surface wave control for large arrays of microwave kinetic inductance detectors
Large ultra-sensitive detector arrays are needed for present and future
observatories for far infra-red, submillimeter wave (THz), and millimeter wave
astronomy. With increasing array size, it is increasingly important to control
stray radiation inside the detector chips themselves, the surface wave. We
demonstrate this effect with focal plane arrays of 880 lens-antenna coupled
Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field
measurements of the MKID optical response versus the position on the array of a
reimaged optical source. We demonstrate that the optical response of a detector
in these arrays saturates off-pixel at the dB level compared to the
peak pixel response. The result is that the power detected from a point source
at the pixel position is almost identical to the stray response integrated over
the chip area. With such a contribution, it would be impossible to measure
extended sources, while the point source sensitivity is degraded due to an
increase of the stray loading. However, we show that by incorporating an
on-chip stray light absorber, the surface wave contribution is reduced by a
factor 10. With the on-chip stray light absorber the point source response
is close to simulations down to the dB level, the simulation based on
an ideal Gaussian illumination of the optics. In addition, as a crosscheck we
show that the extended source response of a single pixel in the array with the
absorbing grid is in agreement with the integral of the point source
measurements.Comment: accepted for publication in IEEE Transactions on Terahertz Science
and Technolog
Anatomy and Three-Dimensional Reconstructions of the Brain of a Bottlenose Dolphin (Tursiops truncatus) From Magnetic Resonance Images
Cetacean (dolphin, whale, and porpoise) brains are among the least studied mammalian brains because of the formidability of collecting and histologically preparing such relatively rare and large specimens. Magnetic resonance imaging offers a means of observing the internal structure of the brain when traditional histological procedures are not practical. Furthermore, internal structures can be analyzed in their precise anatomic positions, which is difficult to accomplish after the spatial distortions often accompanying histological processing. In this study, images of the brain of an adult bottlenose dolphin, Tursiops truncatus, were scanned in the coronal plane at 148 antero-posterior levels. From these scans a computer-generated three-dimensional model was constructed using the programs Voxel-View and VoxelMath (Vital Images, Inc.). This model, wherein details of internal and external morphology are represented in three-dimensional space, was then resectioned in orthogonal planes to produce corresponding series of virtual sections in the horizontal and sagittal planes. Sections in all three planes display the sizes and positions of major neuroanatomical features such as the arrangement of cortical lobes and subcortical structures such as the inferior and superior colliculi, and demonstrate the utility of MRI for neuroanatomical investigations of dolphin brains
Proof-of-Concept Demonstration of Vector Beam Pattern Measurements of Kinetic Inductance Detectors
We present results from the first vector beam pattern measurement ofmicrowave kinetic inductance detectors (MKIDs). Vector beam patterns require sampling of the E-field of the receiver in both amplitude and phase. MKIDs are inherently direct detectors and have no phase response to incoming radiation. We map the amplitude and phase patterns of the detector beam profile by adapting a two-source heterodyne technique. Our testing strategy recovers the phase information by creating a reference signal to trigger data acquisition. The reference is generated by mixing the slightly offset low-frequency signals from the output of the two synthesizers used to drive the submillimeter sources. The key requirement is that the time-series record always begins at the same set phase of the reference signal. As the source probe is scanned within the receiver beam, the wavefront propagation phase of the receiver changes and causes a phase offset between the detector output and reference signals. We demonstrated this technique on the central pixel of a test array operating at 350 GHz. This methodology will enable vector beam pattern measurements to be performed on direct detectors, which have distinct advantages reducing systematic sources of error, allowing beam propagation, and removing the far-field measurement requirement such that complicated optical systems can be measured at a point that is easily accessible, including the near field
Prototype design of a dielectrically embedded mesh lens
Here we present a prototype design for a
dielectrically embedded mesh lens consisting of stacked
layers of printed circuit board (PCB) material and
embedded copper elements. The dielectrically embedded
mesh lens consists of layers of dielectric which contain subwavelength-
dimension metal elements laid out in a grid
fashion, and is both flat and lightweight. It has been
demonstrated that the sizes of these metal elements can be
varied according to their position in the apparatus, using
models based on transmission line theory, to create a lens
which focuses a plane wave at millimeter wavelength to a
Gaussian beam with very low transmission loss, even
without the use of antireflective coating. We present the
phase design for our lens which was designed, using
transmission line theory and electromagnetic modelling
software, to operate at 20GHz. We further present an\ud
analysis of the transmission line components which will
make up the lens
Prototype design of a dielectrically embedded mesh lens
Here we present a prototype design for a
dielectrically embedded mesh lens consisting of stacked
layers of printed circuit board (PCB) material and
embedded copper elements. The dielectrically embedded
mesh lens consists of layers of dielectric which contain subwavelength-
dimension metal elements laid out in a grid
fashion, and is both flat and lightweight. It has been
demonstrated that the sizes of these metal elements can be
varied according to their position in the apparatus, using
models based on transmission line theory, to create a lens
which focuses a plane wave at millimeter wavelength to a
Gaussian beam with very low transmission loss, even
without the use of antireflective coating. We present the
phase design for our lens which was designed, using
transmission line theory and electromagnetic modelling
software, to operate at 20GHz. We further present an
analysis of the transmission line components which will
make up the lens
Annotated Genome Sequence of the High-Biomass-Producing Yellow-Green Alga Tribonema minus
Here, we report the annotated genome sequence for a heterokont alga from the class Xanthophyceae. This high-biomass-producing strain, Tribonema minus UTEX B 3156, was isolated from a wastewater treatment plant in California. It is stable in outdoor raceway ponds and is a promising industrial feedstock for biofuels and bioproducts
Antiviral susceptibility of clade 2.3.4.4b highly pathogenic avian influenza A(H5N1) viruses isolated from birds and mammals in the United States, 2022
Clade 2.3.4.4b highly pathogenic avian influenza (HPAI) A(H5N1) viruses that are responsible for devastating outbreaks in birds and mammals pose a potential threat to public health. Here, we evaluated their susceptibility to influenza antivirals. Of 1,015 sequences of HPAI A(H5N1) viruses collected in the United States during 2022, eight viruses (∼0.8%) had a molecular marker of drug resistance to an FDA-approved antiviral: three adamantane-resistant (M2-V27A), four oseltamivir-resistant (NA-H275Y), and one baloxavir-resistant (PA-I38T). Additionally, 31 viruses contained mutations that may reduce susceptibility to inhibitors of neuraminidase (NA) (n = 20) or cap-dependent endonuclease (CEN) (n = 11). A panel of 22 representative viruses was tested phenotypically. Overall, clade 2.3.4.4b A(H5N1) viruses lacking recognized resistance mutations were susceptible to FDA-approved antivirals. Oseltamivir was least potent at inhibiting NA activity, while the investigational NA inhibitor AV5080 was most potent, including against NA mutants. A novel NA substitution T438N conferred 12-fold reduced inhibition by zanamivir, and in combination with the known marker N295S, synergistically affected susceptibility to all five NA inhibitors. In cell culture-based assays HINT and IRINA, the PA-I38T virus displayed 75- to 108-fold and 37- to 78-fold reduced susceptibility to CEN inhibitors, baloxavir and the investigational AV5116, respectively. Viruses with PA-I38M or PA-A37T showed 5- to 10-fold reduced susceptibilities. As HPAI A(H5N1) viruses continue to circulate and evolve, close monitoring of drug susceptibility is needed for risk assessment and to inform decisions regarding antiviral stockpiling
Antiviral Susceptibility of Clade 2344b Highly Pathogenic Avian Influenza A(H5N1) Viruses Isolated From Birds and Mammals in the United States, 2022
Clade 2.3.4.4b highly pathogenic avian influenza (HPAI) A(H5N1) viruses that are responsible for devastating outbreaks in birds and mammals pose a potential threat to public health. Here, we evaluated their susceptibility to influenza antivirals. Of 1,015 sequences of HPAI A(H5N1) viruses collected in the United States during 2022, eight viruses (∼0.8%) had a molecular marker of drug resistance to an FDA-approved antiviral: three adamantane-resistant (M2-V27A), four oseltamivir-resistant (NA-H275Y), and one baloxavir-resistant (PA-I38T). Additionally, 31 viruses contained mutations that may reduce susceptibility to inhibitors of neuraminidase (NA) (n = 20) or cap-dependent endonuclease (CEN) (n = 11). A panel of 22 representative viruses was tested phenotypically. Overall, clade 2.3.4.4b A(H5N1) viruses lacking recognized resistance mutations were susceptible to FDA-approved antivirals. Oseltamivir was least potent at inhibiting NA activity, while the investigational NA inhibitor AV5080 was most potent, including against NA mutants. A novel NA substitution T438N conferred 12-fold reduced inhibition by zanamivir, and in combination with the known marker N295S, synergistically affected susceptibility to all five NA inhibitors. In cell culture-based assays HINT and IRINA, the PA-I38T virus displayed 75- to 108-fold and 37- to 78-fold reduced susceptibility to CEN inhibitors, baloxavir and the investigational AV5116, respectively. Viruses with PA-I38M or PA-A37T showed 5- to 10-fold reduced susceptibilities. As HPAI A(H5N1) viruses continue to circulate and evolve, close monitoring of drug susceptibility is needed for risk assessment and to inform decisions regarding antiviral stockpiling
MKID Exoplanet Camera for Subaru SCExAO
We present the MKID Exoplanet Camera (MEC), a z through J band (800–1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument and is designed to operate both as an IFU, and as a focal plane wavefront sensor in a multi-kHz feedback loop with SCExAO. The read noise free, fast time domain information attainable by MKIDs allows for the direct probing of fast speckle fluctuations that currently limit the performance of most high contrast imaging systems on the ground and will help MEC achieve its ultimate goal of reaching contrasts of 10⁻⁷ at 2 λ/D. Here we outline the instrument details of MEC including the hardware, firmware, and data reduction and analysis pipeline. We then discuss MEC's current on-sky performance and end with future upgrades and plans
- …