Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries
Abstract
Background
Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres.
Methods
This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries.
Results
In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia.
Conclusion
This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries
Surgical treatment of neuroendocrine tumors of the lung
Objective: This report reviews the pattern of neuroendocrine (NE) differentiation, lymph-node involvement, extension of surgery, and survival in 125 NE lung tumor patients. Methods: Standard diagnostic workup included CT scan, bronchoscopy, bronchial biopsy or Fine Needle Aspiration Biopsy, 111In-pentetreotide scan (OctreoScan) and mediastinoscopy in selected patients. NE differentiation was assessed based on the morphology and immunohistochemical reactivity for pan-neuroendocrine markers NSE, CGA, and Synaptophysin. For small cell carcinoma (SCC), only clinical stage I and II patients underwent surgery. Several different surgical procedures were utilized, from limited resections to lobectomy, pneumonectomy, and bronchoplastic procedures. Survival was assessed using Kaplan-Meyer method at 5 years. Results: There were 79 typical carcinoid (TC), eight atypical carcinoid (AC), 18 large cell carcinoma (LCC) and 20 SCC patients. Mean age at diagnosis was 54.6\ub115.2 (ranges from 16 to 77 years) for TC, 68.5\ub19.1 (range 53-81) for AC, 68.7\ub14.6 (range 58-77) for LCC, 64.6\ub17.9 (range 48-82) for SCC. Male/female ratio was 1/1 for TC and AC, 2.6/1 for LCC and 9/1 for SCC. Lymph-node involvement was present in 14% of TC, 0% of AC, 31.5% of LCC, and 45% of SCC. Cancer specific survival was 96% for TC, 87.5% for AC, 37.5% for LCC, and 30% for SCC at 5 years from surgery. Presenting symptoms were invariably of respiratory-related. None had the carcinoid syndrome. History of tobacco abuse ranged from 46% for TC to 100% in SCC. Survival ranged from a minimum of 1 month for SCC to a maximum of 168 months with no evidence of disease for TC. Synchronous multicentric forms were found in 14% of TC. Twenty-one percent (4/19) of the patients with SCC treated by induction therapy and surgery, and in few cases by surgery and adjuvant chemotherapy are alive without the evidence of the disease for 5 years. Conclusions: Due to the high percentage of lymph-node involvement and multicentric forms found in our series lobectomy with radical lymph-node dissection appears, in our opinion, the most appropriate surgical treatment in well-differentiated forms, while more limited resection appears sub-optimal. Also, due to the finding of recurrences many years after surgery, the follow-up must be accurate and protracted in this subgroup. Only Small Cell Lung Carcinoma patients in clinical stage I and II underwent surgery with good long-term results. \ua9 2004 Elsevier B.V. All rights reserved
Long-term safety and tolerance of silicone and self-expandable airway stents: an experimental study
BACKGROUND:
A variety of respiratory stents are currently available, but the ideal airway prosthesis seems far from being recognized. The objective of this study was to verify safety and long-term effect on the bronchial wall of three different types of airway stents.
METHODS:
Twelve healthy adult sheep were divided in three groups, scheduled to receive: (1) bare self-expandable metallic stents (Gianturco); (2) silicone stents (Dumon); and (3) covered self-expandable synthetic stents (Polyflex). Insertions were performed through a rigid bronchoscope under general anesthesia. Chest roentgenogram was performed 1 and 6 months after surgery, and flexible bronchoscopy after 6 months. Twelve months postoperatively, the animals were killed and a postmortem examination was carried out.
RESULTS:
All Polyflex stents migrated during the observation period; one late migration was observed in the Dumon group. Microscopic study showed: (1) Gianturco stents: full-thickness perforation of the bronchial wall covered by a thick layer of a chronic inflammatory infiltrate. Infection by Candida at the bottom of some ulcerations; (2) Dumon stents: mild bronchial inflammation (squamous metaplasia, submucosal inflammatory infiltrates; granuloma-like infiltrates). In case of displacement, no significant changes of the previously stented bronchus occurred; and (3) Polyflex stents: no changes of the previously stented bronchi.
CONCLUSIONS:
Gianturco stents proved unsafe in the long term, owing to the risk of severe airway wall damage. The Polyflex stent is well tolerated but presents a high migration rate. Silicone stents show several limitations but appear to be well tolerated by the host mucosa
Preservation of the inferior mesenteric artery in colorectal resection for complicated diverticular disease
Background: Preservation of the inferior mesenteric artery (IMA) and consequential blood flow to the rectum would reduce the risk of leakage of a colorectal anastomosis. Methods: One hundred and sixty-three patients undergoing left colectomy for complicated diverticular disease of the colon were randomly placed into two groups: A, n = 86; and B, n = 77. In group A, the integrity of the IMA was preserved by artery skeletization (IMAS); in group B, the IMA was divided at its origin. Variables recorded included duration of the surgical procedure, need for blood transfusion, length of hospital stay, operative mortality and morbidity, staple-ring disruption, and radiologic and clinical leakage. Anastomotic stenosis and recurrence of diverticular disease were noted. Results: Surgical time was superior in the IMAS group. Radiologic and clinical leakages were significantly higher in group B (P = 0.02, P = 0.03, respectively). In group A a significant lower number of staple-ring disruptions was observed, evolving into clinical dehiscence. Conclusion: Preserving the natural blood supply to the rectum and the ensuing use of a healthy well-nourished rectal stump are suggested as the main aspects of IMAS in preventing and healing leakage of colorectal anastomosis. © 2001 Excerpta Medica, Inc. All rights reserved