722 research outputs found

    Low dose CT-based spatial analysis (CTSA) to measure implant migration after ceramic hip resurfacing arthroplasty (HRA): a phantom study

    Get PDF
    Implant migration is a predictor of arthroplasty survivorship. It is crucial to monitor the migration of novel hip prostheses within premarket clinical investigations. RSA is the gold standard method, but requires calibrated radiographs using specialised equipment. A commercial computed tomography micromotion analysis solution is a promising alternative but is not yet available for use with monobloc ceramic implants. This study aimed to develop and validate a CT-based spatial analysis (CTSA) method for use with ceramic implants. A phantom study was undertaken to assess accuracy and precision. A ceramic hip resurfacing arthroplasty (HRA) and 20 tantalum beads were implanted into a synthetic hip model and mounted onto a 6-degree of freedom motion stage. The hip was repeatedly scanned with a low dose CT protocol, with imposed micromovements. Data were interrogated using a semiautomated technique. The effective radiation dose for each scan was estimated to be 0.25 mSv. For the head implant, precision ranged between 0.11 and 0.28 mm for translations and 0.34°-0.42° for rotations. For the cup implant, precision ranged between 0.08 and 0.11 mm and 0.19° and 0.42°. For the head, accuracy ranged between 0.04 and 0.18 mm for translations and 0.28°-0.46° for rotations. For the cup, accuracy ranged between 0.04 and 0.08 mm and 0.17° and 0.43°. This in vitro study demonstrates that low dose CTSA of a ceramic HRA is similar in accuracy to RSA. CT is ubiquitous, and this method may be an alternative to RSA to measure prosthesis migration

    The revision partial knee classification system: understanding the causative pathology and magnitude of further surgery following partial knee arthroplasty.

    Get PDF
    AIMS: Joint registries classify all further arthroplasty procedures to a knee with an existing partial arthroplasty as revision surgery, regardless of the actual procedure performed. Relatively minor procedures, including bearing exchanges, are classified in the same way as major operations requiring augments and stems. A new classification system is proposed to acknowledge and describe the detail of these procedures, which has implications for risk, recovery, and health economics. METHODS: Classification categories were proposed by a surgical consensus group, then ranked by patients, according to perceived invasiveness and implications for recovery. In round one, 26 revision cases were classified by the consensus group. Results were tested for inter-rater reliability. In round two, four additional cases were added for clarity. Round three repeated the survey one month later, subject to inter- and intrarater reliability testing. In round four, five additional expert partial knee arthroplasty surgeons were asked to classify the 30 cases according to the proposed revision partial knee classification (RPKC) system. RESULTS: Four classes were proposed: PR1, where no bone-implant interfaces are affected; PR2, where surgery does not include conversion to total knee arthroplasty, for example, a second partial arthroplasty to a native compartment; PR3, when a standard primary total knee prosthesis is used; and PR4 when revision components are necessary. Round one resulted in 92% inter-rater agreement (Kendall's W 0.97; p < 0.005), rising to 93% in round two (Kendall's W 0.98; p < 0.001). Round three demonstrated 97% agreement (Kendall's W 0.98; p < 0.001), with high intra-rater reliability (interclass correlation coefficient (ICC) 0.99; 95% confidence interval 0.98 to 0.99). Round four resulted in 80% agreement (Kendall's W 0.92; p < 0.001). CONCLUSION: The RPKC system accounts for all procedures which may be appropriate following partial knee arthroplasty. It has been shown to be reliable, repeatable and pragmatic. The implications for patient care and health economics are discussed. Cite this article: Bone Jt Open 2021;2(8):638-645

    Training safer surgeons: How do patients view the role of simulation in orthopaedic training?

    Get PDF
    BACKGROUND: Simulation allows training without posing risk to patient safety. It has developed in response to the demand for patient safety and the reduced training times for surgeons. Whilst there is an increasing role of simulation in orthopaedic training, the perception of patients and the general public of this novel method is yet unknown. Patients and the public were given the opportunity to perform a diagnostic knee arthroscopy on a virtual reality ARTHRO Mentor simulator. After their practice session, participants answered a validated questionnaire based on a 5-point Likert Scale assessing their opinions on arthroscopic simulation. Primary objective was observing perception of patients on orthopaedic virtual reality simulation. FINDINGS: There were a total of 159 respondents, of which 86% were of the opinion that simulators are widely used in surgical training and 94% felt that they should be compulsory. 91% would feel safer having an operation by a surgeon trained on simulators, 87% desired their surgeon to be trained on simulators and 72% believed that additional simulator training resulted in better surgeons. Moreover, none of the respondents would want their operation to be performed by a surgeon who had not trained on a simulator. Cronbach's alpha was 0.969. CONCLUSIONS: There is also a clear public consensus for this method of training to be more widely utilised and it would enhance public perception of safer training of orthopaedic surgeons. This study of public perception provides a mandate to increase investment and infrastructure in orthopaedic simulation as part of promoting clinical governance

    Synchrotron imaging assessment of bone quality

    No full text
    Bone is a complex hierarchical structure and its principal function is to resist mechanical forces and fracture. Bone strength depends not only on the quantity of bone tissue but also on the shape and hierarchical structure. The hierarchical levels are interrelated, especially the micro-architecture, collagen and mineral components; hence analysis of their specific roles in bone strength and stiffness is difficult. Synchrotron imaging technologies including micro-CT and small/wide angle X-Ray scattering/diffraction are becoming increasingly popular for studying bone because the images can resolve deformations in the micro-architecture and collagen-mineral matrix under in situ mechanical loading. Synchrotron cannot be directly applied in-vivo due to the high radiation dose but will allow researchers to carry out systematic multifaceted studies of bone ex-vivo. Identifying characteristics of aging and disease will underpin future efforts to generate novel devices and interventional therapies for assessing and promoting healthy aging. With our own research work as examples, this paper introduces how synchrotron imaging technology can be used with in-situ testing in bone research

    Immersive virtual reality enables technical skill acquisition for scrub nurses in complex revision total knee arthroplasty.

    Get PDF
    INTRODUCTION: Immersive Virtual Reality (iVR) is a novel technology which can enhance surgical training in a virtual environment without supervision. However, it is untested for the training to select, assemble and deliver instrumentation in orthopaedic surgery-typically performed by scrub nurses. This study investigates the impact of an iVR curriculum on this facet of the technically demanding revision total knee arthroplasty. MATERIALS AND METHODS: Ten scrub nurses completed training in four iVR sessions over a 4-week period. Initially, nurses completed a baseline real-world assessment, performing their role with real equipment in a simulated operation assessment. Each subsequent iVR session involved a guided mode, where the software taught participants the procedural choreography and assembly of instrumentation in a simulated operating room. In the latter three sessions, nurses also undertook an assessment in iVR. Outcome measures were related to procedural sequence, duration of surgery and efficiency of movement. Transfer of skills from iVR to the real world was assessed in a post-training simulated operation assessment. A pre- and post-training questionnaire assessed the participants knowledge, confidence and anxiety. RESULTS: Operative time reduced by an average of 47% across the 3 unguided sessions (mean 55.5 ± 17.6 min to 29.3 ± 12.1 min, p > 0.001). Assistive prompts reduced by 75% (34.1 ± 16.8 to 8.6 ± 8.8, p < 0.001), dominant hand motion by 28% (881.3 ± 178.5 m to 643.3 ± 119.8 m, p < 0.001) and head motion by 36% (459.9 ± 99.7 m to 292.6 ± 85.3 m, p < 0.001). Real-world skill improved from 11% prior to iVR training to 84% correct post-training. Participants reported increased confidence and reduced anxiety in scrubbing for rTKA procedures (p < 0.001). CONCLUSIONS: For scrub nurses, unfamiliarity with complex surgical procedures or equipment is common. Immersive VR training improved their understanding, technical skills and efficiency. These iVR-learnt skills transferred into the real world

    Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging.

    Get PDF
    Many papers have been published recently on the subject of pseudotumors surrounding metal-on-metal hip resurfacing and replacement prostheses. These pseudotumors are sterile, inflammatory lesions within the periprosthetic tissues and have been variously termed masses, cysts, bursae, collections, or aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL). The prevalence of pseudotumors in patients with a well-functioning metal-on-metal hip prosthesis is not well known. The purpose of this study was to quantify the prevalence of pseudotumors adjacent to well-functioning and painful metal-on-metal hip prostheses, to characterize these lesions with use of magnetic resonance imaging, and to assess the relationship between their presence and acetabular cup position with use of three-dimensional computed tomography

    Collaborative team training in virtual reality is superior to individual learning for performing complex open surgery: a randomised controlled trial

    Get PDF
    Objective: To assess if multiplayer virtual reality (VR) training was superior to single player training for acquisition of both technical and non-technical skills in learning complex surgery. Summary Background Data: Superior team-work in the operating room (OR) is associated with improved technical performance and clinical outcomes. VR can successfully train OR staff individually, however VR team training has yet to be investigated. Method: Forty participants were randomised to individual or team VR training. Individually-trained participants practiced alongside virtual avatar counterparts, whilst teams trained live in pairs. Both groups underwent five VR training sessions over 6-weeks. Subsequently, they underwent a real-life assessment in which they performed Anterior Approach Total Hip Arthroplasty (AA-THA) surgery on a high-fidelity model with real equipment in a simulated OR. Teams performed together and individually-trained participants were randomly paired up. Videos were marked by two blinded assessors recording the NOTSS, NOTECHS II and SPLINTS scores. Secondary outcomes were procedure time and number of technical errors. Results: Teams outperformed individually-trained participants for non-technical skills in the real-world assessment (NOTSS 13.1±1.5 vs 10.6±1.6, P=0.002, NOTECHS-II score 51.7±5.5 vs 42.3±5.6, P=0.001 and SPLINTS 10±1.2 vs 7.9±1.6, P=0.004). They completed the assessment 28.1% faster (27.2 minutes±5.5 vs 41.8 ±8.9, P<0.001), and made fewer than half the number of technical errors (10.4±6.1 vs 22.6±5.4, P<0.001). Conclusions: Multiplayer training leads to faster surgery with fewer technical errors and the development of superior non-technical skills

    El Niño, tropical Atlantic warmth, and Atlantic hurricanes over the past 1500 years

    Get PDF
    Author Posting. © The Author(s), 2009. This is the author's version of the work. It is posted here by permission of Nature Publishing Group for personal use, not for redistribution. The definitive version was published in Nature 460 (2009): 880-883, doi:10.1038/nature08219.Atlantic Tropical Cyclone (TC) activity, as measured by annual storm counts, reached anomalous levels over the past decade. The short nature of the historical record and potential issues with its reliability in earlier decades, however, has prompted an ongoing debate regarding the reality and significance of the recent rise. Here, we place recent activity in a longer-term context, by comparing two independent estimates of TC activity over the past 1500 years. The first estimate is based on a composite of regional sedimentary evidence of landfalling hurricanes, while the second estimate employs a previously published statistical model of Atlantic TC activity driven by proxy-reconstructions of past climate changes. Both approaches yield consistent evidence of a peak in Atlantic TC activity during Medieval times (around AD 1000) followed by a subsequent lull in activity. The Medieval peak, which rivals or even exceeds (within uncertainties) recent levels of activity, results in the statistical model from a ‘perfect storm’ of La Niña-like climate conditions and relative tropical Atlantic warmth.M.E.M. and Z.Z. acknowledge support from the ATM programme of the National Science Foundation (grant ATM-0542356). J.P.D. acknowledges support from the EAR and OCE programmes of the National Science Foundation (grants EAR-0519118 and OCE-0402746), the Risk Prediction Initiative at the Bermuda Institute for Ocean Sciences, and the Inter-American Institute for Global Change Research

    Are component positioning and prosthesis size associated with hip resurfacing failure?

    Get PDF
    BACKGROUND: Recent studies suggest that there is a learning curve for metal-on-metal hip resurfacing. The purpose of this study was to assess whether implant positioning changed with surgeon experience and whether positioning and component sizing were associated with implant longevity. METHODS: We evaluated the first 361 consecutive hip resurfacings performed by a single surgeon, which had a mean follow-up of 59 months (range, 28 to 87 months). Pre and post-operative radiographs were assessed to determine the inclination of the acetabular component, as well as the sagittal and coronal femoral stem-neck angles. Changes in the precision of component placement were determined by assessing changes in the standard deviation of each measurement using variance ratio and linear regression analysis. Additionally, the cup and stem-shaft angles as well as component sizes were compared between the 31 hips that failed over the follow-up period and the surviving components to assess for any differences that might have been associated with an increased risk for failure. RESULTS: Surgeon experience was correlated with improved precision of the antero-posterior and lateral positioning of the femoral component. However, femoral and acetabular radiographic implant positioning angles were not different between the surviving hips and failures. The failures had smaller mean femoral component diameters as compared to the non-failure group (44 versus 47 millimeters). CONCLUSIONS: These results suggest that there may be differences in implant positioning in early versus late learning curve procedures, but that in the absence of recognized risk factors such as intra-operative notching of the femoral neck and cup inclination in excess of 50 degrees, component positioning does not appear to be associated with failure. Nevertheless, surgeons should exercise caution in operating patients with small femoral necks, especially when they are early in the learning curve
    corecore