8,113 research outputs found
Redundant motor drive system
A drive system characterized by a base supporting a pair of pillars arranged in spaced parallelism, a shaft extended between and supported by the pillars for rotation about the longitudinal axis thereof, a worm gear affixed to the shaft and supported in coaxial relation therewith is described. A bearing housing of a sleeve like configuration is concentrically related to the shaft and is supported thereby for free rotation. A first and a second quiescent drive train, alternatively activatable, is provided for imparting rotation into said bearing housing. Each of the drive trains is characterized by a selectively energizable motor connected to a spur gear
A polarimeter for the high resolution ultraviolet spectrometer/polarimeter
The design requirements of the polarimeter were established by the scientific optical objectives of the experiment to be launched aboard the Solar Max Mission which will study active solar regions. The polarization of the light is accomplished by a rotating magnesium fluoride quarter wave plate. The quarter wave plates are rotated in 22 1/2 degree steps about an axis coincidental with the light beam. As the light beam passes through the wave plate, the transformation that occurs can be expressed by mathematical equations. By having the wave plates calibrated, the data obtained from solar flares can be analyzed and meaningful information provided to the investigators. The polarimeter has two wave plates with different optical characteristics to provide both redundancy and versatility. A four mirror polarizer was added behind one wave plate to provide additional polarization. The mechanical design, testing, and operation of the polarimeter for the high resolution ultraviolet spectrometer/polarimeter are described
Modification and improvements to cooled blades Patent
Modification and improvement of turbine blades for maximum cooling efficienc
IMPULSE moment-by-moment test:An implicit measure of affective responses to audiovisual televised or digital advertisements
IMPULSE is a novel method for detecting affective responses to dynamic audiovisual content. It is an implicit reaction time test that is carried out while an audiovisual clip (e.g., a television commercial) plays in the background and measures feelings that are congruent or incongruent with the content of the clip. The results of three experiments illustrate the following four advantages of IMPULSE over self-reported and biometric methods: (1) being less susceptible to typical confounds associated with explicit measures, (2) being easier to measure deep-seated and often nonconscious emotions, (3) being better able to detect a broad range of emotions and feelings, and (4) being more efficient to implement as an online method.Published versio
Full-field pulsed magneto-photoelasticity – Experimental Implementation
This paper contains a description of the experimental procedure employed when using a pulsed-magneto-polariscope (PMP) and some initial full-field through-thickness measurements of the stress distribution present in samples containing 3D stresses. The instrument uses the theory of magneto-photoelasticity (MPE), which is an experimental stress analysis technique that involves the application of a magnetic field to a birefringent model within a polariscope. MPE was developed for through-thickness stress measurement where the integrated through-thickness birefringent measurement disguises the actual stress distribution. MPE is mainly used in toughened glass where the through-thickness distribution can reduce its overall strength and so its determination is important.
To date MPE has been a single-point 2D through-thickness measurement and the analysis time is prohibitive for the investigation of an area which may contain high localised stresses. The pulsed-magneto-polariscope (PMP) has been designed to enable the application of full-field 3D MPE [ ]. Using a proof-of concept PMP several experimental measurements were made, these were promising and demonstrate the potential of the new instrument. Further development of this technique presents several exciting possibilities including a tool for the measurement of the distribution of principal stress difference seen in a general 3D model
Review of Alamo Images: Changing Perceptions of a Texas Experience
Alamo Images is a catalog to accompany an exhibition of artifacts, artworks, books, broadsides, ephemera, memorabilia, pamphlets, motion picture posters, and other items relating to the Alamo that were displayed at Southern Methodist University in 1985 and 1986. The stated purpose of the book and of the exhibition was to help explain both the Alamo of historical fact and the Alamo of our imagination (p. 17). The general intellectual assumption behind the book was that the myth of the Alamo had evolved into such a historical icon of patriotism that any attempt at sorting out truth from fanciful fiction would lead defenders of the myth to see fact finders as betrayers of Anglo-American values
Ultrasonic locating devices for central venous cannulation: meta-analysis
OBJECTIVES: To assess the evidence for the clinical
effectiveness of ultrasound guided central venous
cannulation.
DATA SOURCES: 15 electronic bibliographic databases,
covering biomedical, science, social science, health
economics, and grey literature.
DESIGN: Systematic review and meta-analysis of
randomised controlled trials.
POPULATIONS: Patients scheduled for central venous
access.
INTERVENTION REVIEWED: Guidance using real time two
dimensional ultrasonography or Doppler needles and
probes compared with the anatomical landmark
method of cannulation.
DATA EXTRACTION: Risk of failed catheter placement
(primary outcome), risk of complications from
placement, risk of failure on first attempt at
placement, number of attempts to successful
catheterisation, and time (seconds) to successful
catheterisation.
DATA SYNTHESIS: 18 trials (1646 participants) were
identified. Compared with the landmark method, real
time two dimensional ultrasound guidance for
cannulating the internal jugular vein in adults was
associated with a significantly lower failure rate both
overall (relative risk 0.14, 95% confidence interval
0.06 to 0.33) and on the first attempt (0.59, 0.39 to
0.88). Limited evidence favoured two dimensional
ultrasound guidance for subclavian vein and femoral
vein procedures in adults (0.14, 0.04 to 0.57 and 0.29,
0.07 to 1.21, respectively). Three studies in infants
confirmed a higher success rate with two dimensional
ultrasonography for internal jugular procedures (0.15,
0.03 to 0.64). Doppler guided cannulation of the
internal jugular vein in adults was more successful
than the landmark method (0.39, 0.17 to 0.92), but the
landmark method was more successful for subclavian
vein procedures (1.48, 1.03 to 2.14). No significant
difference was found between these techniques for
cannulation of the internal jugular vein in infants. An
indirect comparison of relative risks suggested that
two dimensional ultrasonography would be more
successful than Doppler guidance for subclavian vein
procedures in adults (0.09, 0.02 to 0.38).
CONCLUSIONS: Evidence supports the use of two
dimensional ultrasonography for central venous
cannulation
- …