48 research outputs found

    Central Sleep Apnoea and Arrhythmogenesis After Myocardial Infarction – The CESAAR Study

    Get PDF
    The prevalence of sleep disordered breathing (SDB) after acute myocardial infarction (AMI) is high. However, little is known about predominant SDB type and the impact of SDB severity on arrhythmogenesis. We conducted a prospective single-center observational study and performed an unattended sleep study and Holter monitoring within 10 days after AMI, and an unattended sleep study 11.3 months after AMI. All patients were included from the Department of Cardiology at the University Hospital Schleswig-Holstein, Lübeck, Germany. A total of 202 subjects with AMI (73.8% with ST-elevation; 59.8 years; 73.8% male) were included. The mean BMI was 27.8 kg/m2 and the mean neck/waist circumference was 41.7/103.3 cm. The mean left ventricular ejection fraction was 56.6%. The SDB prevalence defined as apnoea-hypopnea-index (AHI) ≥ 5/h was 66.7% with 44.9% having central (CSA), and 21.8% obstructive sleep apnoea (OSA). The mean AHI was 13.8 1/h. In 10.2% nsVT was detected in the Holter monitoring. AI >23/h was independently associated with higher risk of nsVT in the subacute AMI period. SDB is highly prevalent and CSA a predominant type of SDB in the subacute phase after uncomplicated AMI treated with modern revascularization procedures and evidence-based pharmacological therapy. Severe SDB is independently associated with higher risk for nsVT in the subacute AMI period and its course should be monitored as it can potentially have a negative impact on relevant outcomes of AMI patients. Further prospective studies are needed to assess long-term follow up of SDB after AMI and its impact on mortality and morbidity

    Iyengar Yoga Increases Cardiac Parasympathetic Nervous Modulation Among Healthy Yoga Practitioners

    Get PDF
    Relaxation techniques are established in managing of cardiac patients during rehabilitation aiming to reduce future adverse cardiac events. It has been hypothesized that relaxation-training programs may significantly improve cardiac autonomic nervous tone. However, this has not been proven for all available relaxation techniques. We tested this assumption by investigating cardiac vagal modulation during yoga.We examined 11 healthy yoga practitioners (7 women and 4 men, mean age: 43 ± 11; range: 26–58 years). Each individual was subjected to training units of 90 min once a week over five successive weeks. During two sessions, they practiced a yoga program developed for cardiac patients by B.K.S. Iyengar. On three sessions, they practiced a placebo program of relaxation. On each training day they underwent ambulatory 24 h Holter monitoring. The group of yoga practitioners was compared to a matched group of healthy individuals not practicing any relaxation techniques. Parameters of heart rate variability (HRV) were determined hourly by a blinded observer. Mean RR interval (interval between two R-waves of the ECG) was significantly higher during the time of yoga intervention compared to placebo and to control (P < 0.001 for both). The increase in HRV parameters was significantly higher during yoga exercise than during placebo and control especially for the parameters associated with vagal tone, i.e. mean standard deviation of NN (Normal Beat to Normal Beat of the ECG) intervals for all 5-min intervals (SDNNi, P < 0.001 for both) and root mean square successive difference (rMSSD, P < 0.01 for both). In conclusion, relaxation by yoga training is associated with a significant increase of cardiac vagal modulation. Since this method is easy to apply with no side effects, it could be a suitable intervention in cardiac rehabilitation programs

    Differences between students and physicians in their entitlement towards procedural skills education – a needs assessment of skills training in internal medicine

    Get PDF
    Objective: Procedural skills education has a high priority for medical students. However, it is not clear what kind of skills they consider important and whether their perception differs from the physicians’ view

    Quality assurance process within the RAdiosurgery for VENtricular TAchycardia (RAVENTA) trial for the fusion of electroanatomical mapping and radiotherapy planning imaging data in cardiac radioablation

    Full text link
    A novel quality assurance process for electroanatomical mapping (EAM)-to-radiotherapy planning imaging (RTPI) target transport was assessed within the multi-center multi-platform framework of the RAdiosurgery for VENtricular TAchycardia (RAVENTA) trial. A stand-alone software (CARDIO-RT) was developed to enable platform independent registration of EAM and RTPI of the left ventricle (LV), based on pre-generated radiotherapy contours (RTC). LV-RTC were automatically segmented into the American-Heart-Association 17-segment-model and a manual 3D-3D method based on EAM 3D-geometry data and a semi-automated 2D-3D method based on EAM screenshot projections were developed. The quality of substrate transfer was evaluated in five clinical cases and the structural analyses showed substantial differences between manual target transfer and target transport using CARDIO-RT

    Subcutaneous or Transvenous Defibrillator Therapy.

    Get PDF
    BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.)

    Curriculare Übung zum Verfassen von Arztbriefen im vierten Jahr des Medizinstudiums – Einschätzungen der Teilnehmer nach zwei Jahren

    Full text link
    Weitz G, Friederichs H, Twesten C, Bonnemeier H, Lehnert H, Wellhöner P. Curriculare Übung zum Verfassen von Arztbriefen im vierten Jahr des Medizinstudiums – Einschätzungen der Teilnehmer nach zwei Jahren. Wiener Medizinische Wochenschrift. 2015;165(5-6):86-90

    An unusual cause of inappropriate shocks delivered by an implantable cardioverter defibrillator

    Full text link
    Abstract Introduction Cardiac implantable electronic device (CIED) complications present significant challenges in clinical practice, especially in elderly patients with multiple comorbidities. Common adverse events include infection, lead malfunction, and device migration. Twiddler’s Syndrome, a rare but serious CIED complication characterised by patient manipulation causing lead displacement and device malfunction, is often underreported. The literature consists mainly of case reports and small series, providing limited guidance on prevention and management. As CIEDs are critical for managing cardiac arrhythmias and heart failure, understanding and addressing Twiddler’s Syndrome is essential. This case report aims to contribute to the literature by detailing a case of Twiddler’s Syndrome, emphasising the importance of a multidisciplinary approach for optimal management. Case Presentation A 59-year-old male presented with discomfort around his implantable cardioverter defibrillator (ICD) site and the sternal area over the past two days. He denied pain, dyspnoea, or dizziness. Clinical examination revealed a normal heart rhythm and no peripheral pulse deficit. Ultrasound revealed a reduced left ventricular ejection fraction. The atrial lead was not visible, and the shock coil was misplaced. ICD interrogation showed inappropriate shocks due to sensing artifacts and exit block in both leads, with no arrhythmias detected. An X-ray confirmed lead dislodgement and significant entanglement in the pocket. The patient was diagnosed with Twiddler’s Syndrome and scheduled for surgical revision. Discussion/Conclusions Dilated cardiomyopathy (DCM), characterised by left ventricular dilatation and dysfunction, accounts for a significant proportion of systolic heart failure cases. Despite advancements in heart failure management, DCM patients remain at high risk for sudden cardiac death (SCD), making ICD implantation crucial. However, CIED placement carries risks of complications, including Twiddler’s Syndrome. This condition can lead to lead dislodgement and device malfunction, resulting in inappropriate shocks and potential patient harm. In this case, a single-session extraction and re-implantation were successfully performed using a multidisciplinary approach, emphasising the importance of comprehensive management strategies to address such complications effectively. Regular follow-up showed no adverse events, highlighting the procedure’s success and the potential benefits of using advanced antimicrobial adjuncts to prevent infections. This case underscores the need for awareness and standardised protocols for managing Twiddler’s Syndrome to improve patient outcomes in the growing population of CIED recipients

    Effects of a rater training on rating accuracy in a physical examination skills assessment

    Full text link
    [english] Background: The accuracy and reproducibility of medical skills assessment is generally low. Rater training has little or no effect. Our knowledge in this field, however, relies on studies involving video ratings of overall clinical performances. We hypothesised that a rater training focussing on the frame of reference could improve accuracy in grading the curricular assessment of a highly standardised physical head-to-toe examination.Methods: Twenty-one raters assessed the performance of 242 third-year medical students. Eleven raters had been randomly assigned to undergo a brief frame-of-reference training a few days before the assessment. 218 encounters were successfully recorded on video and re-assessed independently by three additional observers. Accuracy was defined as the concordance between the raters' grade and the median of the observers' grade. After the assessment, both students and raters filled in a questionnaire about their views on the assessment.Results: Rater training did not have a measurable influence on accuracy. However, trained raters rated significantly more stringently than untrained raters, and their overall stringency was closer to the stringency of the observers. The questionnaire indicated a higher awareness of the halo effect in the trained raters group. Although the self-assessment of the students mirrored the assessment of the raters in both groups, the students assessed by trained raters felt more discontent with their grade.Conclusions: While training had some marginal effects, it failed to have an impact on the individual accuracy. These results in real-life encounters are consistent with previous studies on rater training using video assessments of clinical performances. The high degree of standardisation in this study was not suitable to harmonize the trained raters’ grading. The data support the notion that the process of appraising medical performance is highly individual. A frame-of-reference training as applied does not effectively adjust the physicians' judgement on medical students in real-live assessments

    Salvage of Cardiac Implantable Electronic Device Pocket Infection with Skin Erosion in Frail 92-Year-Old

    Get PDF
    We reported the novel use of a taurolidine-containing antimicrobial solution in the successful salvage of a partially exposed and polymicrobially infected cardiac implantable electronic device pulse generator in a frail patient unfit for lead extraction. The old, salvaged device was entirely internalized, and there were no signs of recurrent infection at 9 months follow-up
    corecore