125 research outputs found

    Beta-blockers in sepsis: time to reconsider current constraints?

    Get PDF

    Disparity between skin perfusion and sublingual microcirculatory alterations in severe sepsis and septic shock: a prospective observational study

    Get PDF
    Objective: Measurement of central-to-toe temperature difference has been advocated as an index of severity of shock and as a guide for circulatory therapy in critically ill patients. However, septic shock, in contrast to other forms of shock, is associated with a distributive malfunction resulting in a disparity between vascular compartments. Although this disparity has been established between systemic and microcirculatory parameters, it is unclear whether such disparity exists between skin perfusion and microcirculation. To test this hypothesis of disparity, we simultaneously measured parameters of the two vascular compartments, in the early phase of sepsis. Design: Prospective observational study in patients with severe sepsis/septic shock in the first 6 h of ICU admission. Simultaneous measurements of central-to-toe temperature difference and sublingual microcirculatory orthogonal polarization spectral imaging, together with parameters of systemic hemodynamics. Setting: 22 bed mixed-ICU in a tertiary teaching hospital. Patients: 35 consecutive patients in a 12-month period. Measurements and results: In 35 septic patients and a median APACHE II score of 20, no correlation between central-to-toe temperature gradient and microvascular flow index was observed (r(s) =-0.08, p = 0.65). Also no significant correlation between temperature gradient/microvascular flow index and systemic hemodynamic parameters could be demonstrated. Conclusions: During the early phase of resuscitated severe sepsis and septic shock there appears to be no correlation between sublingual microcirculatory alterations and the central-to-toe temperature difference. This finding adds to the concept of a dispersive nature of blood flow under conditions of sepsis between microcirculatory and systemic hemodynamic

    Improvement of Sidestream Dark Field Imaging with an Image Acquisition Stabilizer

    Get PDF
    Background: In the present study we developed, evaluated in volunteers, and clinically validated an image acquisition stabilizer (IAS) for Sidestream Dark Field (SDF) imaging.Methods: The IAS is a stainless steel sterilizable ring which fits around the SDF probe tip. The IAS creates adhesion to the imaged tissue by application of negative pressure. The effects of the IAS on the sublingual microcirculatory flow velocities, the force required to induce pressure artifacts (PA), the time to acquire a stable image, and the duration of stable imaging were assessed in healthy volunteers. To demonstrate the clinical applicability of the SDF setup in combination with the IAS, simultaneous bilateral sublingual imaging of the microcirculation were performed during a lung recruitment maneuver (LRM) in mechanically ventilated critically ill patients. One SDF device was operated handheld; the second was fitted with the IAS and held in position by a mechanic arm. Lateral drift, number of losses of image stability and duration of stable imaging of the two methods were compared.Results: Five healthy volunteers were studied. The IAS did not affect microcirculatory flow velocities. A significantly greater force had to applied onto the tissue to induced PA with compared to without IAS (0.25 ± 0.15 N without vs. 0.62 ± 0.05 N with the IAS, p < 0.001). The IAS ensured an increased duration of a stable image sequence (8 ± 2 s without vs. 42 ± 8 s with the IAS, p < 0.001). The time required to obtain a stable image sequence was similar with and without the IAS. In eight mechanically ventilated patients undergoing a LRM the use of the IAS resulted in a significantly reduced image drifting and enabled the acquisition of significantly longer stable image sequences (24 ± 5 s without vs. 67 ± 14 s with the IAS, p = 0.006).Conclusions: The present study has validated the use of an IAS for improvement of SDF imaging by demonstrating that the IAS did not affect microcirculatory perfusion in the microscopic field of view. The IAS improved both axial and lateral SDF image stability and thereby increased the critical force required to induce pressure artifacts. The IAS ensured a significantly increased duration of maintaining a stable image sequence
    corecore