65 research outputs found

    2-designs having an intersection number knk-n

    Get PDF
    In this paper we examine 2-designs having an intersection number k - n. This intersection number gives rise to an equivalence relation on the blocks of the design. Conditions on the sizes of these equivalence classes and some properties of any further intersection numbers are obtained. If such a design has at most three intersection numbers then it gives rise to a strongly regular graph. This leads to a result on the embedding of quasi-residual designs. As as example a quasi-residual 2-(56, 12, 3) design is constructed and embedded in a symmetric 2-(71, 15, 3) design

    Hebeloma vesterholtii, a new species in section Theobromina

    No full text
    The species Hebeloma vesterholtii spec. nov. is described. It is morphologically and molecularly closely related to Hebeloma theobrominum from which it can be distinguished using either morphological or molecular characters. Both of these species belong to section Theobromina. The new species is known from 13 collections from six European countries

    Hebeloma species associated with Cistus

    No full text
    The genus Hebeloma has a number of species highly specific to Cistus and others that occur with several host genera. This paper discusses the species of Hebeloma that appear to be ectomycorrhizal with Cistus, judging from their occurrence when Cistus is the only available host. The previously unknown species H. plesiocistum spec. nov. is described. We also provide a key to the known Hebeloma associates of Cistus. Molecular analyses based on ITS sequence data further illustrate the distinctness of the newly described species and difficulties in the species delimitation with view to H. erumpens. Specific associations with Cistus may have evolved more than once within the genus Hebeloma

    State observers and Kalman filtering for high performance vibration isolation systems

    No full text
    There is a strong scientific case for the study of gravitational waves at or below the lower end of current detection bands. To take advantage of this scientific benefit, future generations of ground based gravitational wave detectors will need to expand the limit of their detection bands towards lower frequencies. Seismic motion presents a major challenge at these frequencies and vibration isolation systems will play a crucial role in achieving the desired low-frequency sensitivity. A compact vibration isolation system designed to isolate in-vacuum optical benches for Advanced Virgo will be introduced and measurements on this system are used to present its performance. All high performance isolation systems employ an active feedback control system to reduce the residual motion of their suspended payloads. The development of novel control schemes is needed to improve the performance beyond what is currently feasible. Here, we present a multi-channel feedback approach that is novel to the field. It utilizes a linear quadratic regulator in combination with a Kalman state observer and is shown to provide effective suppression of residual motion of the suspended payload. The application of state observer based feedback control for vibration isolation will be demonstrated with measurement results from the Advanced Virgo optical bench suspension system. © 2014 AIP Publishing LLC

    Status of the Virgo project

    No full text
    We describe the present state and future evolution of the Virgo gravitational wave detector, realized by the Virgo Collaboration at the European Gravitational Observatory, in Cascina near Pisa in Italy. We summarize basic principles of the operation and the design features of the Virgo detector. We present the sensitivity evolution due to a series of intermediate upgrades called Virgo+ which is being completed this year and includes new monolithic suspensions. We describe the present scientific potential of the detector. Finally we discuss the plans for the second generation of the detector, called Advanced Virgo, introducing its new features, the expected sensitivity evolution and the scientific potential. © 2011 IOP Publishing Ltd

    Seismic attenuation technology for the Advanced Virgo gravitational wave detector

    Get PDF
    AbstractThe current interferometric gravitational wave detectors are being upgraded to what are termed ‘second generation’ devices. Sensitivities will be increased by an order of magnitude and these new instruments are expected to uncover the field of gravitational astronomy. A main challenge in this endeavor is the mitigation of noise induced by seismic motion. Detailed studies with Virgo show that seismic noise can be reinjected into the dark fringe signal. For example, laser beam jitter and backscattered light limit the sensitivity of the interferometer.Here, we focus on seismic attenuators based on compact inverted pendulums in combination with geometric anti-prings to obtain 40 dB of attenuation above 4 Hz in six degrees of freedom. Low frequency resonances (< 0.5 Hz) are damped by using a control system based on input from LVDTs and geophones. Such systems are under development for the seismic attenuation of optical benches operated both in air and vacuum. The design and realization of the seismic attenuation system for the Virgo external injection bench, including its control scheme, will be discussed and stand-alone performance presented

    Seismic attenuation system for the external injection bench of the Advanced Virgo gravitational wave detector

    No full text
    In November 2011 a major upgrade of the Virgo gravitational wave detector was started. After these improvements the detector's sensitivity will have increased by an order of magnitude, increasing the expected event rate by 103 compared to its predecessor. Extensive noise studies showed that this improvement can only be accomplished if a number of optical benches, hosting ancillary optics and optical sensors for the alignment of the interferometer, are isolated from seismic ground motion to reduce the amount of beam jitter and control noise they introduce. Here we present the first of these systems: the External Injection Bench Seismic Attenuation System, or EIB-SAS, which is able to reduce seismically induced motion of the external injection bench (last bench before laser beam enters the vacuum system) by more than 40 dB above 10 Hz in 6 degrees of freedom

    Seismic attenuation system for the external injection bench of the Advanced Virgo gravitational wave detector

    No full text
    In November 2011 a major upgrade of the Virgo gravitational wave detector was started. After these improvements the detector's sensitivity will have increased by an order of magnitude, increasing the expected event rate by 1
    corecore