11 research outputs found

    A Large-Scale Fifteen-Year Minimum Survivorship of a Cementless Triple Tapered Femoral Stem

    Get PDF
    © 2020 Elsevier Inc. Background: This study reports the long-term outcomes of a metaphyseal fit-and-fill cementless femoral component in total hip arthroplasty (THA) with a follow-up of 15-19 years. Methods: We conducted a retrospective review of 376 consecutive THAs (345 patients), using a triple tapered stem performed between 2000 and 2003 with a view to assessing survivorship and radiological and functional outcomes. Images were assessed for initial alignment, terminal osteolysis, or subsidence, while clinical outcomes were assessed using the St Michael\u27s Hip Score. Results: Forty-five (11.9%) hips were lost to follow-up, 20 (5.31%) had died before our 15-year cutoff follow-up, and 4 (1.06%) had declined follow-up early on, leaving 307 hips (81.64%, 276 patients) available for both clinical and radiological follow-up at a minimum of 15 years (range 15-19). The mean age at the time of operation was 49.6 years (range 19-71) and the cohort included 131 (42.67%) male and 145 (47.23%) female patients. Seven stems (2.28%) were revised: 4 due to periprosthetic fractures, 2 for periprosthetic joint infection, and 1 for adverse reaction to metal debris at the trunnion. The St Michael\u27s Hip Score improved from 14.2 (range 9-23) preoperatively to 22.3 (range 13 to 25) at the last documented follow-up (P = .000). Kaplan-Meier survivorship with stem revision for any reason as the end point was 97.70%. Worst-case scenario Kaplan-Meier survivorship, where all lost to follow-up are considered as failures, was 85.3%. No stem was revised for aseptic loosening. Conclusion: This triple tapered stem in THA shows excellent survivorship beyond a minimum of 15 years

    Accelerated surgery versus standard care in hip fracture (HIP ATTACK): an international, randomised, controlled trial

    Get PDF

    A Geometric Analysis of Polyethylene Liners Exposed to Acrylic-based Bone Cement

    No full text
    Background: Acrylic-based bone cement (polymethyl methacrylate [PMMA]) is a material commonly used in orthopaedic surgeries; however, during PMMA polymerization, a highly exothermic reaction occurs. The heat released in polymerization can damage nearby materials including poorly heat-resistant cross-linked polyethylene (XLPE). Both PMMA and XLPE are used in total hip arthroplasty and could interact during femoral stem fixation. We sought to determine if the exothermic polymerization of PMMA could alter the surface characteristics of XLPE acetabular liners. Methods: Six XLPE liners were assigned to one of 4 experimental categories with varying volumes of PMMA applied in a manner that mimicked how the 2 materials would come into contact intraoperatively. Measurements were taken both pre- and post-intervention using a coordinate measuring machine for geometric and gravimetric analysis. Light microscopy was conducted postintervention to examine the surface for damage. Results: Coordinate measuring machine measurements showed minimal gross deformation in all 6 liners, but there were isolated surface deposits in 4 of 6 liners. The average maximal surface deviations, when compared to the control, for liners exposed to 1 cc of cement, 2 cc of cement, or 1 cc of cement with a femoral head implant attached were 26.6 μm, 77.2 μm, and 26.4 μm, respectively. All but one liner showed an increase in volume following intervention when compared to the control. Subtle scratches were identified using light microscopy on all 6 liners. Conclusions: XLPE shows areas of isolated surface deformation in a dose-dependent manner but with minimal gross deformation after interacting with highly exothermic PMMA

    Mortality rate of geriatric acetabular fractures is high compared with hip fractures. A matched cohort study

    No full text
    © 2020 Lippincott Williams and Wilkins. All rights reserved. Objectives:Compare acute complication and mortality rates of geriatric patients with acetabular fractures (AFs) matched to hip fractures (HFs).Design:Retrospective cohort study.Setting:American College of Surgeons National Surgical Quality Improvement Project.Patients:Using Current Procedural Terminology codes, the American College of Surgeons National Surgical Quality Improvement Project registry was used to identify all patients ≥60 years from 2011 to 2016 treated for AFs undergoing open reduction internal fixation (ORIF) and HFs (undergoing ORIF, hemiarthroplasty, or cephalomedullary nail).Outcome Measurements:Patient characteristics, comorbidities, functional status, acute complications, and mortality rates were recorded. Patients were matched 1:5 (AF:HF). Chi-square, Fisher exact, and Mann-Whitney U tests were used to compare groups, and multivariable logistic regression was used to compare the risk of complications or death while adjusting for relevant covariates.Results:A total of 303 AF patients (age: 78.2 ± 9.2 years/59.7% females/27.1% wall, 28.4% one column and 45.2% 2 columns ORIF) were matched to 1511 HF patients (age: 78.3 ± 9.1 years/60.2% females/37.2% hemiarthroplasty, 16.3% ORIF and 47.4% cephalomedullary nail). Length of stay (8.4 ± 7.1 vs. 6.4 ± 5.9 days) and time to surgery [(TS) 2.3 ± 1.8 versus 1.2 ± 1.4 days] were longer in the AF group (P \u3c 0.01). Unadjusted mortality rates were nonsignificantly higher for AFs versus HFs (6.6% vs. 4.6%, P = 0.14). After covariable adjustment, the risk of mortality was significantly higher for AFs versus HFs (odds ratio: 1.89, 95% confidence interval: 1.07-3.35).Conclusion:Geriatric AFs pose a significantly higher adjusted mortality risk when compared with HF patients. Strategies to mitigate risk factors in this population are warranted.Level of Evidence:Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence

    The Ideal Total Hip Replacement Bearing Surface in the Young Patient: A Prospective Randomized Trial Comparing Alumina Ceramic-On-Ceramic With Ceramic-On-Conventional Polyethylene: 15-Year Follow-Up

    No full text
    © 2017 Background: The optimum bearing surface for total hip arthroplasty remains debatable. We have previously published our outcome at 10 years and this represents the 15-year follow-up. Methods: A total of 58 hips (in 57 patients with a mean age of 42 years) were randomized to receive either ceramic-on-ceramic (CoC) or ceramic-on-polyethylene (CoP) total hip arthroplasty. We prospectively followed for survivorship, functional outcomes (using the Harris Hip Score and the St Michael\u27s Hip Score [SMH]), and radiological outcomes. Results: At a minimum of 15 years, 3 patients had died, but not been revised. Seven were lost to follow-up. Five cases from the CoP group were revised (4 for polyethylene wear and osteolysis). Four from the CoC were revised; one each for head fracture, instability, infection, and trunnionosis. Both groups showed statistically significant improvements in Harris Hip Score scores and SMH functional scores, with no difference between the 2 bearings. For the CoP group, there was an improvement from 15.6 to 21.5 in the SMH and from 48.8 to 88.7 (P \u3e.05); and for CoC, this improvement was 15.8 to 23.5 and 50.3 to 94.6 (P \u3e.05), respectively. Mean wear rate of the polyethylene was 0.092 mm/y and for the CoC was 0.018 mm/y. Two patients in the CoC group had evidence of acetabular osteolysis vs 3 in the CoP. Six patients had femoral osteolysis in the CoC group and 12 in the CoP group. Conclusion: Survivorship and function of the 2 bearing groups remains comparable; while the polyethylene wear and osteolysis may represent issues in the future
    corecore