6 research outputs found

    Impact of reduction of flux overlap region on kilovoltage cone-beam computed tomography image quality and patients’ exposure dose

    Get PDF
    AimIn high-precision radiation therapy, kilovoltage cone-beam computed tomography plays an important role in verifying the position of patient and localization of the target. However, the exposure dose is a problem with kilovoltage cone-beam computed tomography. Flux overlap region increases the patient dose around the center when the scan is performed in a full-scan mode. We assessed the influence of flux overlap region in a full-scan mode to understand the relationship between dose and image quality and investigated methods to achieve a dose reduction.MethodA Catphan phantom was scanned using various flux overlap region patterns in the pelvis on a full-scan mode. We used an intensity-modulated radiation therapy phantom for measuring the central dose. DoseLab was used to perform image analysis and to evaluate the linearity of the computed tomography values, uniformity, high-contrast resolution, and contrast-to-noise ratio.ResultsThe Hounsfield unit value varied by ±40 Hounsfield unit of the acceptance value for the X1 field size of 3.5[[ce:hsp sp="0.25"/]]cm. However, there were no differences in high-contrast resolution and contrast-to-noise ratio among different scan patterns. The absorbed dose decreased by 7% at maximum for the case within the tolerance value.ConclusionDose reduction is possible by reducing the overlap region after calibration and by performing computed tomography in the appropriate overlap region

    Automatic acquisition of CT radiation dose data: Using the diagnostic reference level for radiation dose optimization

    No full text
    The present work describes that we try to construct a system that collects dose information that performed CT examination from multiple facilities and unified management. The results of analysis are compared with other National diagnostic reference level (DRL), and the results are fed back to each facility and the cause of the abnormal value is investigated for dose optimization. Medical information collected 139 144 tests from 33 CT devices in 13 facilities. Although the DRL of this study is lower than that of Japan DRL, it was higher than the DRL of each country. When collecting all the examination, it is thought that the variation of the dose due to the error other than the intended imaging site is large. In future, we should continue to collect information in order to DRL renewal and we also think that it is desirable to collect information on physique and detailed scan region as well
    corecore