    Prédiction de l'hématocrite post dilution sous circulation extra-corporelle: de nouvelles formules sont-elles nécessaires?

    Full text link
    Objectives: Predicting the post-dilution hematocrit is an important tool to avoid preventable anemia or unnecessary transfusion. Simplified empirical formulas currently used for such a prediction may lead to large errors. We aimed to improve the accuracy of these formulas by a better estimation of the dilution volume and the patient circulatory blood volume. Methods: We compared the estimation accuracy of two formulas, using fixed (formula A) versus estimated (formula D) dilution volume and patient circulatory blood volume for 100 cardiac interventions. The difference between predicted and measured HctT1 was considered as “good” if less than 0.5%, “moderate” between 0.5 and 2% and “poor” if higher than 2%. The influence of the body mass index (BMI) on patient blood volume estimation was explored by categorized groups’ comparison. Results: The mean difference between predicted and measured HctT1 differed significantly between formulas A and D. Formula A didn’t differ from HctT1 (p=0.19, IC95% [-0.89-0.18]), but a significant and higher underestimation was observed in the BMI⩽25 group compared to the other BMI groups (p<0.001). Formula D overestimated HctT1 (p<0.001, IC95% [1.01-1.93]) without a difference between the BMI groups. No difference was observed in their overall proportions of good (11 vs 10%), moderate (44 vs 46%) and poor predictions (47 vs 44%) (p=0.117). Conclusions: Formulas used for post-dilution hematocrit prediction lead to major estimation errors and a risk of inadequate transfusion practices. Estimations performed by experienced clinicians could not minimize these biases in all clinical cases as significant errors remain, with potential clinical impact. No estimation formula should be used as a hard tool for transfusing patients, but rather as a guide to predicting the probability of transfusion requirement

    Telerobotic contact transscleral cyclophotocoagulation of the ciliary body with the diode laser

    No full text
    To assess the feasibility of using the Robotic Slave Micromanipulator Unit (RSMU) to remotely photocoagulate the ciliary body for the treatment of glaucoma with the diode laser. In fresh unoperated enucleated human eyes, the ciliary body was destroyed either with a standard contact transscleral cyclophotocoagulation \u27by hand\u27 diode laser technique, or remotely using the RSMU. The treated sections were fixed in formalin, paraffin-embedded, and stained with hematoxylin and eosin. Histological evaluation was performed by a masked observer using a standardized grading system based on the amount of damage to the ciliary body to evaluate effectiveness of treatment. Both methods of contact transscleral cyclophotocoagulation showed therapeutic tissue disruption of the ciliary processes and both the non-pigmented and pigmented ciliary epithelium. Histology examination of remote robotic contact transscleral cyclophotocoagulation and by hand technique produced similar degrees of ciliary body tissue disruption. Remote diode laser contact transscleral cyclophotocoagulation of the ciliary body in fresh enucleated human eyes is possible with the RSMU. Therapeutic tissue disruption of the ciliary body was achieved. Additional study is necessary to determine the safety and efficacy of robotically-delivered cyclophotocoagulation in live eyes. © 2013 Springer-Verlag London
    corecore