286 research outputs found

    Effect of microstructure on dry sliding wear behaviour in CuZnAl shape memory alloys

    Get PDF
    The main objective of this work has been the characterization of the wear behaviour of the CuZnAl shape memory alloys in their different phases. The weight losses for the different alloys in function of the present phase, and of the Ms transformation temperature are studied. Adhesive wear tests, Pin-on-Disk, according to the ASTM-G99 standard have been carried out. After this a characterization of the wear surfaces by means of optical microscopy, scanning electron microscopy, differential scanning calorimetry and X-ray diffraction have also been carried out. We can observe that the wear behaviour of this alloy depends on the shape memory properties. For the ß shape memory alloys a lineal relation of weight loss with Ms transformation temperatures are obtained. For the martensitic phase and ß+ martensitic phase the relation weight loss–Ms is not evident.Postprint (published version

    Antimicrobial peptides: Powerful biorecognition elements to detect bacteria in biosensing technologies

    Get PDF
    Bacterial infections represent a serious threat in modern medicine. In particular, biofilm treatment in clinical settings is challenging, as biofilms are very resistant to conventional antibiotic therapy and may spread infecting other tissues. To address this problem, biosensing technologies are emerging as a powerful solution to detect and identify bacterial pathogens at the very early stages of the infection, thus allowing rapid and effective treatments before biofilms are formed. Biosensors typically consist of two main parts, a biorecognition moiety that interacts with the target (i.e., bacteria) and a platform that transduces such interaction into a measurable signal. This review will focus on the development of impedimetric biosensors using antimicrobial peptides (AMPs) as biorecognition elements. AMPs belong to the innate immune system of living organisms and are very effective in interacting with bacterial membranes. They offer unique advantages compared to other classical bioreceptor molecules such as enzymes or antibodies. Moreover, impedance-based sensors allow the development of label-free, rapid, sensitive, specific and cost-effective sensing platforms. In summary, AMPs and impedimetric transducers combine excellent properties to produce robust biosensors for the early detection of bacterial infectionsPeer ReviewedPostprint (published version

    Procesos de adiestramiento de alambres ortodóncicos con memoria de forma

    Get PDF
    Los alambres de ortodoncia de níquel-titanio son suministrados por los diferentes fabricantes con forma de arco estándar. Los procesos de adiestramiento o de "eduación" permiten cambiar las formas del arco dental del alambre. Esta propiedad permitirá que el material a una temperatura tenga una forma y que a una temperatura menor recuerde otra forma diferente. Este doblre efecto memoria de forma proporciona al clínico una mayor versatilidad de los alambres NiTi en el tratamiento ortodóncico.Peer Reviewe

    Aplicación y caracterización físico-química de varios tratamientos superficiales realizados al acero inoxidable 316 L para aplicacions biomédicas

    Get PDF
    La biocompatibilidad de los metales utilizados en implantología está íntimamente relacionada con las características superficiales de los implantes tanto desde un punto de vista químico como topográfico. El objetivo de este trabajo es aplicar varios tratamientos superficiales al acero inoxidable 316 L y caracterizar, posteriormente, la superficie físico-químicamente. La superficie pulida de varios discos de acero 316 L fue tratada mediante los procesos de: granallado, variando el tamaño y la naturaleza de la partículas proyectadas, y anodizado electroquímico. Con el fin de caracterizar las superficies obtenidas con cada tratamiento se observó la morfología superficial mediante Microscopia Electrónica de Barrido e Inteferometría Óptica y se evaluó el efecto de dichos tratamientos en la resistencia a la corrosión y en la liberación de iones níquel y cromo mediante ensayos in vitro. Los resultados revelaron que el tratamiento de granallado permite obtener un amplio rango de rugosidades incrementando el área real hasta un 54% pero disminuyendo ligeramente la resistencia a la corrosión del material. El proceso de anodizado prácticamente no tuvo efectos en la topografía sin embargo redujo considerablemente la resistencia a la corrosión del metal. Todos los tratamientos estudiados disminuyeron ligeramente la liberación de iones cromo y níquel

    Aplicación y caracterización físico-química de varios tratamientos superficiales realizados al acero inoxidable 316L para aplicaciones biomédicas

    Get PDF
    La biocompatibilidad de los metales utilizados en implantología está íntimamente relacionada con las características superficiales de los implantes tanto desde un punto de vista químico como topográfico. El objetivo de este trabajo es aplicar varios tratamientos superficiales al acero inoxidable 316 L y caracterizar, posteriormente, la superficie físico-químicamente. La superficie pulida de varios discos de acero 316 L fue tratada mediante los procesos de: granallado, variando el tamaño y la naturaleza de la partículas proyectadas, y anodizado electroquímico. Con el fin de caracterizar las superficies obtenidas con cada tratamiento se observó la morfología superficial mediante Microscopia Electrónica de Barrido e Inteferometría Óptica y se evaluó el efecto de dichos tratamientos en la resistencia a la corrosión y en la liberación de iones níquel y cromo mediante ensayos in vitro. Los resultados revelaron que el tratamiento de granallado permite obtener un amplio rango de rugosidades incrementando el área real hasta un 54% pero disminuyendo ligeramente la resistencia a la corrosión del material. El proceso de anodizado prácticamente no tuvo efectos en la topografía sin embargo redujo considerablemente la resistencia a la corrosión del metal. Todos los tratamientos estudiados disminuyeron ligeramente la liberación de iones cromo y níquel

    Impedimetric antimicrobial peptide-based sensor for the early detection of periodontopathogenic bacteria

    Get PDF
    Peri-implantitis, an inflammation caused by biofilm formation, constitutes a major cause of implant failure in dentistry. Thus, the detection of bacteria at the early steps of biofilm growth represents a powerful strategy to prevent implant-related infections. In this regard, antimicrobial peptides (AMPs) can be used as effective biological recognition elements to selectively detect the presence of bacteria. Thus, the aim of the present study was to combine the use of miniaturized and integrated impedimetric transducers and AMPs to obtain biosensors with high sensitivity to monitor bacterial colonization. Streptococcus sanguinis, which is one of the most prevalent strains in the onset of periodontal diseases, was used as a model of oral bacteria. To this end, a potent AMP derived from human lactoferrin was synthesized and covalently immobilized on interdigitated electrode arrays (IDEA). X-ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS) were employed to optimize and characterize the method of immobilization. Noteworthy, the interaction of Streptococcus sanguinis with AMP-coated sensors provoked significant changes in the impedance spectra, which were univocally associated with the presence of bacteria, proving the feasibility of our method. In this regard, the developed biosensor permits to detect the presence of bacteria at concentrations starting from 101 colony forming units (CFU) mL-1 in KCl and from 102 CFU mL-1 in artificial saliva. Moreover, the system was devoid of cytotoxicity for human fibroblasts. These results indicate that the proposed approach can be effective in the detection of initial stages of biofilm formation, and may be useful in the early prevention and treatment of peri-implantitisPeer ReviewedPostprint (author's final draft

    Cerámicas de circona para aplicaciones biomédicas

    Get PDF
    Se tratan los aspectos mas significativos de distintos biomateriales empleados para la sustitución del tejido óseo pero haciendo énfasis en las cerámicas de óxido de zirconio (circonas). Se destacan las características de las cerámicas de circona que lo convierten en un material muy atractivo por sus excelentes propiedades mecánicas, en particular su elevada tenacidad a la fractura relacionada con la transformación martensítica que se produce cuando el material es sometido a un esfuerzo mecánico. Por esta razón se ha empleado como biomaterial en la fabricación de diversos componentes de prótesis articulares fundamentalmente en las prótesis de cadera. También se han empleado con relativo éxito en otras aplicaciones clínicas como la odontología y la cirugía máxilo-facial. En la actualidad, se trabaja en conferirle bioactividad a las cerámicas de circona para facilitar su unión al tejido óseo sin afectar sus buenas propiedades mecánicas.Peer Reviewe

    Oxidación superficial de aleaciones de NiTi para la mejora de la biocompatibilidad

    Get PDF
    Se han estudiado diferentes tratamientos superficiales con el fin de obtener una capa de TiO2 con una mínima concentración de Ni en la superficie de aleaciones de NiTi 50/50 con memoria de forma: pulido espejo, autoclave, electropulido, oxidación en un baño de agua hirviendo y oxidación térmica en atmósfera controlada de aire. Se analizaron las superficies de las muestras mediante XPS. El tratamiento de oxidación térmica es el que da el ratio Ti/Ni más alto, la menor cantidad de Ni en superficie y también el mayor espesor de óxido. Se comprobó mediante un experimento de liberación de iones que el óxido formado por este proceso de oxidación hace disminuir la liberación de iones Ni al medio fisiológico respecto a la superficie no tratada. Se hicieron estudios de cultivos celulares de osteoblastos de línea MG63 sobre superficies no tratadas y tratadas térmicamente de NiTi. Los resultados de proliferación muestran que, para los días 3, 6 y 9 no existen diferencias estadísticamente significativas entre los materiales. Sin embargo, después de 48h de estimulación para la diferenciación, las células cultivadas sobre las superficies tratadas térmicamente demuestran una mayor actividad de la fosfatasa alcalina y mayores niveles de osteocalcina.Various surface treatments have been studied in order to find the most appropriate in forming a TiO2 with a low Ni content on the surface of equiatomic NiTi alloys. Sample surfaces have been analyzed by XPS. Thermal oxidation treatment in an air-controlled atmosphere leads to the highest Ti/Ni ratio, to the lowest Ni surface concentration and to the thickest oxide layer. It has been shown by the results of ion release experiment that the oxide formed by this oxidation process allows to decrease Ni release into exterior medium comparing with non-treated surfaces. Cell cultures of MG63 osteoblast-like cells have been carried out. The proliferation study shows that from day 3 to day 9 there is no statistically significant differences between negative control, non-treated and thermally oxidized surfaces. After 48h of stimulation for differentiation, MG63 cells on thermally oxidized surfaces show higher phosphatase alkaline activity and osteocalcin level
    corecore