6,786 research outputs found

    A different approach to the narratives about the tear of the boycott document placed inside al-Ka’bah

    Get PDF
    This article examines the narratives with regard to lifting the boycott decisions imposed upon the Prophet Muhammad and his companions. There are basically two narratives about this event. While the first one relies on more accurate knowledge, the other contains a speculative scenario. However, since these two narratives were mixed with each other in time, some contradictory information was narrated, especially information based on a speculative scenario became most popular among the people. At the end, it is understood that the document that included the decisions of boycott was not destroyed in a mysterious way, but torn by a group of people

    Optimal passive filter design for effective utilization of cables and transformers under non-sinusoidal conditions

    Get PDF
    Transformers and cables have overheating and reduced loading capabilities under non-sinusoidal conditions due to the fact that their losses increases with not only rms value but also frequency of the load current. In this paper, it is aimed to employ passive filters for effective utilization of the cables and transformers in the harmonically contaminated power systems. To attain this goal, an optimal passive filter design approach is provided to maximize the power factor definition, which takes into account frequency-dependent losses of the power transmission and distribution equipment, under non-sinusoidal conditions. The obtained simulation results show that the proposed approach has a considerable advantage on the reduction of the total transmission loss and the transformer loading capability under non-sinusoidal conditions when compared to the traditional optimal filter design approach, which aims to maximize classical power factor definition. On the other hand, for the simulated system cases, both approaches lead to almost the same current carrying (or loading) capability value of the cables. © 2014 IEEE.This work is supported by Turkish Republic Ministry of Science, Industry and Technology and BEST Transformers Co. under the project number of 01008.STZ.2011 - 2

    Symmetric factorization of the conformation tensor in viscoelastic fluid models

    Full text link
    The positive definite symmetric polymer conformation tensor possesses a unique symmetric square root that satisfies a closed evolution equation in the Oldroyd-B and FENE-P models of viscoelastic fluid flow. When expressed in terms of the velocity field and the symmetric square root of the conformation tensor, these models' equations of motion formally constitute an evolution in a Hilbert space with a total energy functional that defines a norm. Moreover, this formulation is easily implemented in direct numerical simulations resulting in significant practical advantages in terms of both accuracy and stability.Comment: 7 pages, 5 figure

    An algorithm for optimal sizing of the capacitor banks under non-sinusoidal and unbalanced conditions

    Get PDF
    In non-sinusoidal and unbalanced systems, optimal sizing of the capacitor banks is not a straightforward task as in sinusoidal and balanced systems. In this paper, by means of qualitative and quantitative analysis, it is interpreted that the classical capacitor selection algorithm widely implemented in Reactive Power Control (RPC) relays does not achieve optimal power factor improvement in non-sinusoidal and unbalanced systems. Accordingly, a computationally efficient algorithm is proposed to find the optimal capacitor bank for smart RPC relays. It is further shown in a simulated test case by using Matlab software that the proposed algorithm provides better power factor improvement when compared with the classical algorithm. It is also figured out from the simulation results that both algorithms cause almost the same harmonic distortion and unbalance deterioration levels in the system

    A filter design approach to maximize ampacity of cables in nonsinusoidal power systems

    Get PDF
    This paper presents an optimal design of the C-type passive filters for the effective utilization of the power cables under nonsinusoidal conditions based on maximization of the harmonic derating factor (HDF) of a power cable, where maintaining the load true power factor at an acceptable range is desired. According to IEEE Standard 519, the total harmonic distortions of the voltage and current measured at the point of common coupling are taken into account as main constraints of the proposed approach. The presented numerical results show that the proposed approach provides higher current carrying capacity, or ampacity of the cables under nonsinusoidal conditions when compared to the traditional approaches based on minimization of the current total harmonic distortion and maximization of the true load power factor. A numerical case study is presented to demonstrate the proposed approach
    • …
    corecore