3 research outputs found

    Long-term (>10 years) prognostic value of dobutamine stress echocardiography in a high-risk cohort

    Get PDF
    The prognostic value of dobutamine stress echocardiography (DSE) at >10-year follow-up is unknown. The aim of this study was to assess the very long-term prognostic value of DSE in a high-risk cohort of patients with known or suspected coronary artery disease. This prospective, single-center study included 3,381 patients who underwent DSE from January 1990 to January 2003. Two-dimensional echocardiographic images were acquired at rest, during dobutamine stress, and during recovery. Follow-up events were collected and included overall mortality, cardiac death, nonfatal myocardial infarction, and revascularization. The incremental value of DSE in the prediction of selected end points was evaluated using multivariate Cox proportional hazard analysis. During a mean follow-up of 13 ± 3.2 years (range 7.3 to 20.5 years), there were 1,725 deaths (51%), of which 1,128 (33%) were attributed to cardiac causes. Patients with an abnormal DSE had a higher mortality rate (44% vs 35% at 15-year follow-up, p <0.001) than those with a normal DSE. When comparing echocardiographic variables at rest to variables at maximum dose dobutamine, the chi-square of the test improved from 842 to 870 (p <0.0001) and from 684 to 740 (p <0.0001) for all-cause mortality and cardiac death, respectively. DSE provided incremental value in predicting all-cause mortality, cardiac death, and hard cardiac events. There seems, however, to be a "warranty period" of approximately 7 years, when the survival curves of a normal and abnormal DSE no longer diverge

    Long-term prognostic value of exercise technetium-99m tetrofosmin myocardial perfusion single-photon emission computed tomography

    Get PDF
    Background. Exercise 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) is a useful tool for short- and medium-term risk stratifications. Cur

    Safety of optical coherence tomography in daily practice: a comparison with intravascular ultrasound

    No full text
    Previous studies have reported the safety and feasibility of both time-domain optical coherence tomography (TD-OCT) and Fourier-domain OCT (FD-OCT) in highly selected patients and clinical settings. However, the generalizability of these data is limited, and data in unselected patient populations reflecting a routine cathlab practice are lacking. We compared safety of intracoronary FD-OCT imaging to intravascular ultrasound (IVUS) imaging in a large real-world series of consecutive patients who underwent invasive imaging during coronary catheterization in our centre. This is a prospective, single-centre registry of patients scheduled for coronary angiography or intervention undergoing intracoronary imaging with FD-OCT or IVUS between April 2008 and December 2013. Intra-procedural and major in-hospital adverse events that could be possibly related to invasive imaging were registered routinely by the operator as part of our clinical report and prospectively recorded in our database. These events were retrospectively individually adjudicated by an independent safety committee. Between April 2008 and December 2013, 13 418 diagnostic or interventional coronary catheterization procedures were performed. Of these, 1142 procedures used OCT and 2476 procedures used IVUS. Invasive imaging-related complications were rare, did not differ between the two imaging methods (OCT: n = 7, 0.6%; IVUS: n = 12, 0.5%; P = 0.6), and were self-limiting after retrieval of the imaging catheter or easily treatable in the catheterization laboratory. No major adverse events, prolongation of hospital stay, or permanent patient harm was observed. FD-OCT is safe in an unselected and heterogeneous group of patients with varying clinical settings
    corecore