11 research outputs found
Resectability and Ablatability Criteria for the Treatment of Liver Only Colorectal Metastases:Multidisciplinary Consensus Document from the COLLISION Trial Group
The guidelines for metastatic colorectal cancer crudely state that the best local treatment should be selected from a 'toolbox' of techniques according to patient- and treatment-related factors. We created an interdisciplinary, consensus-based algorithm with specific resectability and ablatability criteria for the treatment of colorectal liver metastases (CRLM). To pursue consensus, members of the multidisciplinary COLLISION and COLDFIRE trial expert panel employed the RAND appropriateness method (RAM). Statements regarding patient, disease, tumor and treatment characteristics were categorized as appropriate, equipoise or inappropriate. Patients with ECOG≤2, ASA≤3 and Charlson comorbidity index ≤8 should be considered fit for curative-intent local therapy. When easily resectable and/or ablatable (stage IVa), (neo)adjuvant systemic therapy is not indicated. When requiring major hepatectomy (stage IVb), neo-adjuvant systemic therapy is appropriate for early metachronous disease and to reduce procedural risk. To downstage patients (stage IVc), downsizing induction systemic therapy and/or future remnant augmentation is advised. Disease can only be deemed permanently unsuitable for local therapy if downstaging failed (stage IVd). Liver resection remains the gold standard. Thermal ablation is reserved for unresectable CRLM, deep-seated resectable CRLM and can be considered when patients are in poor health. Irreversible electroporation and stereotactic body radiotherapy can be considered for unresectable perihilar and perivascular CRLM 0-5cm. This consensus document provides per-patient and per-tumor resectability and ablatability criteria for the treatment of CRLM. These criteria are intended to aid tumor board discussions, improve consistency when designing prospective trials and advance intersociety communications. Areas where consensus is lacking warrant future comparative studies.</p
Colorectal liver metastases: Surgery versus thermal ablation (COLLISION) - a phase III single-blind prospective randomized controlled trial
Background: Radiofrequency ablation (RFA) and microwave ablation (MWA) are widely accepted techniques to eliminate small unresectable colorectal liver metastases (CRLM). Although previous studies labelled thermal ablation inferior to surgical resection, the apparent selection bias when comparing patients with unresectable disease to surgical candidates, the superior safety profile, and the competitive overall survival results for the more recent reports mandate the setup of a randomized controlled trial. The objective of the COLLISION trial is to prove non-inferiority of thermal ablation compared to hepatic resection in patients with at least one resectable and ablatable CRLM and no extrahepatic disease. Methods: In this two-arm, single-blind multi-center phase-III clinical trial, six hundred and eighteen patients with at least one CRLM (≤3cm) will be included to undergo either surgical resection or thermal ablation of appointed target lesion(s) (≤3cm). Primary endpoint is OS (overall survival, intention-to-treat analysis). Main secondary endpoints are overall disease-free survival (DFS), time to progression (TTP), time to local progression (TTLP), primary and assisted technique efficacy (PTE, ATE), procedural morbidity and mortality, length of hospital stay, assessment of pain and quality of life (QoL), cost-effectiveness ratio (ICER) and quality-adjusted life years (QALY). Discussion: If thermal ablation proves to be non-inferior in treating lesions ≤3cm, a switch in treatment-method may lead to a reduction of the post-procedural morbidity and mortality, length of hospital stay and incremental costs without compromising oncological outcome for patients with CRLM. Trial registration:NCT03088150 , January 11th 2017
Neonatal hepatic haemangioendothelioma: treatment options and dilemmas.
We describe a case of rapidly progressive neonatal diffuse hepatic haemangioendotheliomas. The clinical picture was characterized by respiratory insufficiency due to gross abdominal enlargement, coagulopathy, and the development of cardiovascular insufficiency during the course of disease. Pharmacological, radiotherapeutic and endovascular treatment options all proved ineffective. We describe our own experience and the steps taken to treat this child. Unfortunately, the child died as a consequence of the disease. As cases like this are rare and are associated with severe morbidity and high mortality, more knowledge needs to be gained on infantile hepatic haemangioendotheliomas and their optimal treatment. The use of a web-based data registry could be beneficia
Gutter Characteristics and Stent Compression of Self-Expanding vs Balloon-Expandable Chimney Grafts in Juxtarenal Aneurysms Models
Purpose: To assess in silicone juxtarenal aneurysm models the gutter characteristics and compression of different types of chimney graft (CG) configurations. Materials and Methods: Fifty-seven combinations of Excluder C3 or Conformable Excluder stent-grafts (23, 26, and 28.5 mm) were deployed in 2 silicone juxtarenal aneurysm models with 3 types of CGs: Viabahn self-expanding (VSE; 6 and 13 mm) or Viabahn balloon-expandable (VBX; 6, 10, and 12 mm) stent-grafts and Advanta V12 balloon-expandable stent-grafts (ABX; 6 and 12 mm). Setups were divided into 4 groups on the basis of increasing CG and main graft (MG) diameters. Two independent observers assessed gutter size and type as well as CG compression on computed tomography scans using postprocessing software. Results: In the smaller diameter combinations (6-mm CG and 23-, 26-, and 28.5-mm MGs), both VSE (p=0.006 to 0.050) and ABX (p=0.045 to 0.050) showed lower gutter areas and volumes compared with VBX. In turn, the VBX showed a nonsignificant tendency to decreased compression, especially compared to ABX. Use of the Excluder C3 showed a 6-fold increase in type A1 gutters (related to type Ia endoleak) as compared to the Conformable Excluder (p=0.018). Balloon-expandable stent-grafts (both ABX and VBX) showed a 3-fold increase in type A1 gutters in comparison with self-expanding stent-grafts (p=0.008). Conclusion: The current study suggests that use of the Conformable Excluder in combination with VSE chimney grafts is superior to the other tested CG/MG combinations in terms of gutter size, gutter type, and CG compression
Gutter Characteristics and Stent Compression of Self-Expanding vs Balloon-Expandable Chimney Grafts in Juxtarenal Aneurysm Models
Purpose: To assess in silicone juxtarenal aneurysm models the gutter characteristics and compression of different types of chimney graft (CG) configurations. Materials and Methods: Fifty-seven combinations of Excluder C3 or Conformable Excluder stent-grafts (23, 26, and 28.5 mm) were deployed in 2 silicone juxtarenal aneurysm models with 3 types of CGs: Viabahn self-expanding (VSE; 6 and 13 mm) or Viabahn balloon-expandable (VBX; 6, 10, and 12 mm) stent-grafts and Advanta V12 balloon-expandable stent-grafts (ABX; 6 and 12 mm). Setups were divided into 4 groups on the basis of increasing CG and main graft (MG) diameters. Two independent observers assessed gutter size and type as well as CG compression on computed tomography scans using postprocessing software. Results: In the smaller diameter combinations (6-mm CG and 23-, 26-, and 28.5-mm MGs), both VSE (p=0.006 to 0.050) and ABX (p=0.045 to 0.050) showed lower gutter areas and volumes compared with VBX. In turn, the VBX showed a nonsignificant tendency to decreased compression, especially compared to ABX. Use of the Excluder C3 showed a 6-fold increase in type A1 gutters (related to type Ia endoleak) as compared to the Conformable Excluder (p=0.018). Balloon-expandable stent-grafts (both ABX and VBX) showed a 3-fold increase in type A1 gutters in comparison with self-expanding stent-grafts (p=0.008). Conclusion: The current study suggests that use of the Conformable Excluder in combination with VSE chimney grafts is superior to the other tested CG/MG combinations in terms of gutter size, gutter type, and CG compression
Improved Outcomes of Thermal Ablation for Colorectal Liver Metastases: A 10-Year Analysis from the Prospective Amsterdam CORE Registry (AmCORE)
Background: To analyze long-term oncological outcomes of open and percutaneous thermal ablation in the treatment of patients with colorectal liver metastases (CRLM). Methods: This assessment from a prospective, longitudinal tumor registry included 329 patients who underwent 541 procedures for 1350 CRLM from January 2010 to February 2021. Three cohorts were formed: 2010–2013 (129 procedures [53 percutaneous]), 2014–2017 (206 procedures [121 percutaneous]) and 2018–2021 (206 procedures [135 percutaneous]). Local tumor progression-free survival (LTPFS) and overall survival (OS) data were estimated using the Kaplan–Meier method. Potential confounding factors were analyzed with uni- and multivariable Cox regression analyses. Results: LTPFS improved significantly over time for percutaneous ablations (2-year LTPFS 37.7% vs. 69.0% vs. 86.3%, respectively, P <.0001), while LTPFS for open ablations remained reasonably stable (2-year LTPFS 87.1% [2010–2013], vs. 92.7% [2014–2017] vs. 90.2% [2018–2021], P =.12). In the latter cohort (2018–2021), the open approach was no longer superior regarding LTPFS (P =.125). No differences between the three cohorts were found regarding OS (P =.088), length of hospital stay (open approach, P =.065; percutaneous approach, P =.054), and rate and severity of complications (P =.404). The rate and severity of complications favored the percutaneous approach in all three cohorts (P =.002). Conclusion: Over the last 10 years efficacy of percutaneous ablations has improved remarkably for the treatment of CRLM. Oncological outcomes seem to have reached results following open ablation. Given its minimal invasive character and shorter length of hospital stay, whenever feasible, percutaneous procedures may be favored over an open approach
Colorectal liver metastases: Surgery versus thermal ablation (COLLISION) - a phase III single-blind prospective randomized controlled trial
Background: Radiofrequency ablation (RFA) and microwave ablation (MWA) are widely accepted techniques to eliminate small unresectable colorectal liver metastases (CRLM). Although previous studies labelled thermal ablation inferior to surgical resection, the apparent selection bias when comparing patients with unresectable disease to surgical candidates, the superior safety profile, and the competitive overall survival results for the more recent reports mandate the setup of a randomized controlled trial. The objective of the COLLISION trial is to prove non-inferiority of thermal ablation compared to hepatic resection in patients with at least one resectable and ablatable CRLM and no extrahepatic disease. Methods: In this two-arm, single-blind multi-center phase-III clinical trial, six hundred and eighteen patients with at least one CRLM (≤3cm) will be included to undergo either surgical resection or thermal ablation of appointed target lesion(s) (≤3cm). Primary endpoint is OS (overall survival, intention-to-treat analysis). Main secondary endpoints are overall disease-free survival (DFS), time to progression (TTP), time to local progression (TTLP), primary and assisted technique efficacy (PTE, ATE), procedural morbidity and mortality, length of hospital stay, assessment of pain and quality of life (QoL), cost-effectiveness ratio (ICER) and quality-adjusted life years (QALY). Discussion: If thermal ablation proves to be non-inferior in treating lesions ≤3cm, a switch in treatment-method may lead to a reduction of the post-procedural morbidity and mortality, length of hospital stay and incremental costs without compromising oncological outcome for patients with CRLM. Trial registration:NCT03088150 , January 11th 2017
Colorectal liver metastases: surgery versus thermal ablation (COLLISION) – a phase III single-blind prospective randomized controlled trial
Abstract Background Radiofrequency ablation (RFA) and microwave ablation (MWA) are widely accepted techniques to eliminate small unresectable colorectal liver metastases (CRLM). Although previous studies labelled thermal ablation inferior to surgical resection, the apparent selection bias when comparing patients with unresectable disease to surgical candidates, the superior safety profile, and the competitive overall survival results for the more recent reports mandate the setup of a randomized controlled trial. The objective of the COLLISION trial is to prove non-inferiority of thermal ablation compared to hepatic resection in patients with at least one resectable and ablatable CRLM and no extrahepatic disease. Methods In this two-arm, single-blind multi-center phase-III clinical trial, six hundred and eighteen patients with at least one CRLM (≤3 cm) will be included to undergo either surgical resection or thermal ablation of appointed target lesion(s) (≤3 cm). Primary endpoint is OS (overall survival, intention-to-treat analysis). Main secondary endpoints are overall disease-free survival (DFS), time to progression (TTP), time to local progression (TTLP), primary and assisted technique efficacy (PTE, ATE), procedural morbidity and mortality, length of hospital stay, assessment of pain and quality of life (QoL), cost-effectiveness ratio (ICER) and quality-adjusted life years (QALY). Discussion If thermal ablation proves to be non-inferior in treating lesions ≤3 cm, a switch in treatment-method may lead to a reduction of the post-procedural morbidity and mortality, length of hospital stay and incremental costs without compromising oncological outcome for patients with CRLM. Trial registration NCT03088150, January 11th 2017