3 research outputs found

    Effect of INTELLiVENT-ASV versus conventional ventilation on ventilation intensity in patients with COVID-19 ARDS—An observational study

    No full text
    Driving pressure (ΔP) and mechanical power (MP) are associated with outcomes in critically ill patients, irrespective of the presence of Acute Respiratory Distress Syndrome (ARDS). INTELLiVENT-ASV, a fully automated ventilatory mode, controls the settings that affect ΔP and MP. This study compared the intensity of ventilation (ΔP and MP) with INTELLiVENT-ASV versus conventional ventilation in a cohort of COVID-19 ARDS patients in two intensive care units in the Netherlands. The coprimary endpoints were ΔP and MP before and after converting from conventional ventilation to INTELLiVENT-ASV. Compared to conventional ventilation, INTELLiVENT-ASV delivered ventilation with a lower ΔP and less MP. With conventional ventilation, ΔP was 13 cmH2O, and MP was 21.5 and 24.8 J/min, whereas with INTELLiVENT-ASV, ΔP was 11 and 10 cmH2O (mean difference –2 cm H2O (95 %CI –2.5 to –1.2 cm H2O), p < 0.001) and MP was 18.8 and 17.5 J/min (mean difference –7.3 J/Min (95% CI –8.8 to –5.8 J/min), p < 0.001). Conversion from conventional ventilation to INTELLiVENT-ASV resulted in a lower intensity of ventilation. These findings may favor the use of INTELLiVENT-ASV in COVID-19 ARDS patients, but future studies remain needed to see if the reduction in the intensity of ventilation translates into clinical benefits

    Effect of Automated Closed-loop ventilation versus convenTional VEntilation on duration and quality of ventilation in critically ill patients (ACTiVE) – study protocol of a randomized clinical trial

    No full text
    Background INTELLiVENT–Adaptive Support Ventilation (ASV) is a fully automated closed-loop mode of ventilation for use in critically ill patients. Evidence for benefit of INTELLiVENT–ASV in comparison to ventilation that is not fully automated with regard to duration of ventilation and quality of breathing is largely lacking. We test the hypothesis that INTELLiVENT–ASV shortens time spent on a ventilator and improves the quality of breathing. Methods The “Effects of Automated Closed–loop VenTilation versus Conventional Ventilation on Duration and Quality of Ventilation” (ACTiVE) study is an international, multicenter, two-group randomized clinical superiority trial. In total, 1200 intensive care unit (ICU) patients with an anticipated duration of ventilation of > 24 h will be randomly assigned to one of the two ventilation strategies. Investigators screen patients aged 18 years or older at start of invasive ventilation in the ICU. Patients either receive automated ventilation by means of INTELLiVENT–ASV, or ventilation that is not automated by means of a conventional ventilation mode. The primary endpoint is the number of days free from ventilation and alive at day 28; secondary endpoints are quality of breathing using granular breath-by-breath analysis of ventilation parameters and variables in a time frame of 24 h early after the start of invasive ventilation, duration of ventilation in survivors, ICU and hospital length of stay (LOS), and mortality rates in the ICU and hospital, and at 28 and 90 days. Discussion ACTiVE is one of the first randomized clinical trials that is adequately powered to compare the effects of automated closed-loop ventilation versus conventional ventilation on duration of ventilation and quality of breathing in invasively ventilated critically ill patients. The results of ACTiVE will support intensivist in their choices regarding the use of automated ventilation. Trial registration ACTiVE is registered in clinicaltrials.gov (study identifier: NCT04593810) on 20 October 2020
    corecore