58 research outputs found
Can the same edge-detection algorithm be applied to on-line and off-line analysis systems? Validation of a new cinefilm-based geometric coronary measurement software
In the Cardiovascular Measurement System (CMS) the edge-detection algorithm, which was primarily designed for the Philips digital cardiac imaging system (DCI), is applied to cinefilms. Comparative validation of CMS and DCI was performed in vitro and in vivo with intracoronary insertion of stenosis phantoms in anesthetized pigs. The "obstruction diameter" (OD) was measured at the artificial stenoses visualized by angiography with calibration at the isocenter (ISO) and catheter calibration (CATH) and compared with the true phantom diameters. A clinical comparison of OD, reference diameter (RD), and percentage diameter stenosis (DS) was performed on 70 corresponding images from post-PTCA angiograms. In vitro, OD (CMS) yielded an accuracy of 0.18 +/- 0.14 mm with 100% (correlation coefficient: r = 0.97, y = 0.06 + 0.75x, standard error of estimate [SEE] = 0.09) and 0.19 +/- 0.15 mm with 50% contrast (r = 0.94, y = 0.02 + 0.81 x). OD (DCI) yielded an accuracy of 0.11 +/- 0.06 mm with 100% (r = 0.99, y = -0.03 + 0.91 x, SEE = 0.05) and 0.24 +/- 0.13 mm with 50% contrast (r = 0.94, y = 0.29 + 6.69 x, SEE = 0.12). In vivo, OD (CMS) yielded an accuracy of 0.18 +/- 0.23 mm with ISO (r = 0.89, y = 0.02 + 0.83 x, SEE = 0.22) and 0.26 +/- 0.24 mm with CATH (r = 0.89, y = 0.06 + 0.72 x, SEE = 0.19). OD (DCI) yielded an accuracy of 0.08 +/- 0.15 mm with ISO (r = 0.96, y = 0.08 + 0.86 x, SEE = 0.14) and 0.18 +/- 0.21 mm with CATH (r = 0.92, y = 0.09 + 0.76 x, SEE = 0.17). The clinical comparison showed reasonable agreement for OD only (r = 0.81, y = 0.26 + 0.81 x, SEE = 0.29). Transformation of an edge-detection algorithm from a digital to a cinefilm-based system can lead to impairment of measurement reliability
Dietary saturated fat/cholesterol, but not unsaturated fat or starch, induces C-reactive protein associated early atherosclerosis and ectopic fat deposition in diabetic pigs
Background: Diabetes is thought to accelerate cardiovascular disease depending on the type of diet. This study in diabetic subjects was performed to investigate the metabolic, inflammatory and cardiovascular effects of nutritional components typically present in a Western, Mediterranean or high glycaemic diet.Methods: Streptozotocin-diabetic pigs (~45 kg) were fed for 10 weeks supplemental (40% of dietary energy) saturated fat/cholesterol (SFC), unsaturated fat (UF) or starch (S) in an eucaloric dietary intervention study.Results: Fasting plasma total, LDL and HDL cholesterol concentrations were 3-5 fold higher (p < 0.01) in SFC compared to UF and S pigs. Fasting plasma NEFA concentrations (mmol/L) were highest (p < 0.05) in SFC (1.09 ± 0.17), intermediate in UF (0.80 ± 0.14) and lowest in S pigs (0.58 ± 0.14) whereas plasma glucose (~13 mmol/L), triglyceride (~0.5 mmol/L) and insulin (~24 pmol/L) concentrations were comparable among SFC, UF and S pigs. The postprandial response area under the curves (AUC, 0-4 h) for glucose but not for insulin and triglyceride responses were intermediate in SFC (617 ± 144) and lowest (p < 0.05) in UF (378 ± 157) compared to S pigs (925 ± 139). Fasting hepatic glucose production, hepatic and peripheral insulin sensitivity and blood pressure were not different among pigs. C-reactive protein (CRP) concentrations (mg/L) were highest (p < 0.05) in SFC (25 ± 4), intermediate in S (21 ± 3) and lowest in UF pigs (14 ± 2). Liver weights, liver and muscle triglyceride concentrations, and the surface area of aorta fatty streaks were highest (p < 0.01) in SFC pigs. A positive correlation between postprandial plasma CRP and aorta fatty streaks was observed in SFC pigs (R2= 0.95). Retroperitoneal fat depot weight (g) was intermediate in SFC (260 ± 72), lowest in S (135 ± 51) and highest (p < 0.05) in UF (571 ± 95) pigs.Conclusion: Dietary saturated fat/cholesterol induces inflammation, atherosclerosis and ectopic fat deposition whereas an equally high dietary unsaturated fat load does not induce these abnormalities and shows beneficial effects on postprandial glycaemia in diabetic pigs
Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up
BACKGROUND: Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS: Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 microg sirolimus/cm2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revea
The effect of bioresorbable vascular scaffold implantation on distal coronary endothelial function in dyslipidemic swine with and without diabetes
Background: We studied the effect of bioresorbable vascular scaffold (BVS) implantation on distal coronary endothelial function, in swine on a high fat diet without (HFD) or with diabetes (DM + HFD). Methods: Five DM + HFD and five HFD swine underwent BVS implantation on top of coronary plaques, and were studied six months later. Conduit artery segments >. 5. mm proximal and distal to the scaffold and corresponding control segments of non-scaffolded coronary arteries, as well as segments of small arteries within the flow-territories of scaffolded and non-scaffolded arteries were harvested for in vitro vasoreactivity studies. Results: Conduit segments proximal and distal to the BVS edges showed reduced endothelium-dependent vasodilation as compared to control vessels (p <. 0.01), with distal segments being most prominently affected (p <. 0.01). Endothelial dysfunction was only observed in DM + HFD swine and was principally due to a loss of NO. Endothelium-independent vasodilation and vasoconstriction were unaffected. Surprisingly, segments from the microcirculation distal to the BVS showed enhanced endothelium-dependent vasodilation (p <. 0.01), whereas endothelium-independent vasodilation and vasoconstriction were unaltered. This enhanced vasorelaxation was only observed in DM + HFD swine, and did not appear to be either NO- or EDHF-mediated. Conclusions: Six months of BVS implantation in DM + HFD swine causes NO-mediated endothelial dysfunction in nearby coronary segments, which is accompanied by a, possibly compensatory, increase in endothelial function of the distal microcirculation. Endothelial dysfunction extending into coronary conduit segments beyond the implantation-site, is in agreement with recent reports expressing concern for late scaffold thrombosis and of early BVS failure in diabetic patients
Preserved endothelium-dependent vasodilation in coronary segments previously treated with balloon angioplasty and intracoronary irradiation
BACKGROUND: Abnormal endothelium-dependent coronary vasomotion has been
reported after balloon angioplasty (BA), as well as after intracoronary
radiation. However, the long-term effect on coronary vasomotion is not
known. The aim of this study was to evaluate the long-term vasomotion of
coronary segments treated with BA and brachytherapy. METHODS AND RESULTS:
Patients with single de novo lesions treated either with BA followed by
intracoronary beta-irradiation (according to the Beta Energy Restenosis
Trial-1.5) or with BA alone were eligible. Of these groups, those patients
in stable condition who returned for 6-month angiographic follow-up formed
the study population (n=19, irradiated group and n=11, control group).
Endothelium-dependent coronary vasomotion was assessed by selective
infusion of serial doses of acetylcholine (ACh) proximally to the treated
area. Mean luminal diameter was calculated by quantitative coronary
angiography both in the treated area and in distal segments. Endothelial
dysfunction was defined as a vasoconstriction after the maximal dose of
ACh (10(-6) mol/L). Seventeen irradiated segments (89.5%) demonstrated
normal endothelial function. In contrast, 10 distal nonirradiated segments
(53%) and 5 control segments (45%) demonstrated endothelium-dependent
vasoconstriction (-19+/-17% and -9.0+/-5%, respectively). Mean percentage
of change in mean luminal diameter after ACh was significantly higher in
irradiated segments (P=0.01). CONCLUSIONS: Endothelium-dependent
vasomotion of coronary segments treated with BA followed by beta-radiation
is restored in the majority of stabl
Very long sirolimus-eluting stent implantation for de novo coronary lesions.
Long-length stenting has a poor outcome when bare metal stents are used. The safety and efficacy of the sirolimus-eluting stent (SES) in long lesions has not been evaluated. Therefore, the aim of the present study was to evaluate the clinical and angiographic outcomes of SES implantation over a very long coronary artery segment. Since April 2002, all patients treated percutaneously at our institution received a SES as the device of choice as part of the Rapamycin Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. During the RESEARCH registry, stents were available in lengths of 8, 18, and 33 mm. The present report includes a predefined study population consisting of patients treated with >36-mm-long stented segments. Patients had a combination of >or=2 overlapping stents at a minimum length of 41 mm (i.e., one 33-mm SES overlapping an 8-mm SES) to treat native de novo coronary lesions. The incidence of major cardiac adverse events (death, nonfatal myocardial infarction, and target lesion revascularization) was evaluated. The study group comprised 96 consecutive patients (102 lesions). Clinical follow-up was available for all patients at a mean of 320 days (range 265 to 442). In all, 20% of long-stented lesions were chronic total occlusions, and mean stented length per lesion was 61.2 +/- 21.4 mm (range 41 to 134). Angiographic follow-up at 6 months was obtained in 67 patients (71%). Binary restenosis rate was 11.9% and in-stent late loss was 0.13 +/- 0.47 mm. At long-term follow-up (mean 320 days), there were 2 deaths (2.1%), and the overall incidence of major cardiac events was 8.3%. Thus, SES implantation appears safe and effective for de novo coronary lesions requiring multiple stent placement over a very long vessel segment
Towards an integrated approach in surveillance of vector-borne diseases in Europe
Vector borne disease (VBD) emergence is a complex and dynamic process. Interactions between multiple disciplines and responsible health and environmental authorities are often needed for an effective early warning, surveillance and control of vectors and the diseases they transmit. To fully appreciate this complexity, integrated knowledge about the human and the vector population is desirable. In the current paper, important parameters and terms of both public health and medical entomology are defined in order to establish a common language that facilitates collaboration between the two disciplines. Special focus is put on the different VBD contexts with respect to the current presence or absence of the disease, the pathogen and the vector in a given location. Depending on the context, whether a VBD is endemic or not, surveillance activities are required to assess disease burden or threat, respectively. Following a decision for action, surveillance activities continue to assess trends
- …