57 research outputs found
Added value of 18F-FDG-PET/CT and cardiac CTA in suspected transcatheter aortic valve endocarditis
Backgrounds: Transcatheter-implanted aortic valve infective endocarditis (TAVI-IE) is difficult to diagnose when relying on the Duke Criteria. Our aim was to assess the additional diagnostic value of 18F-fluorodeoxyglucose (18F-FDG) positron emission/computed tomography (PET/CT) and cardiac computed tomography angiography (CTA) in suspected TAVI-IE. Methods: A multicenter retrospective analysis was performed in all patients who underwent 18F-FDG-PET/CT and/or CTA with suspected TAVI-IE. Patients were first classified with Duke Criteria and after adding 18F-FDG-PET/CT and CTA, they were classified with European Society of Cardiology (ESC) criteria. The final diagnosis was determined by our Endocarditis Team based on ESC guideline recommendations. Results: Thirty patients with suspected TAVI-IE were included. 18F-FDG-PET/CT was performed in all patients and Cardiac CTA in 14/30. Using the Modified Duke Criteria, patients were classified as 3% rejected (1/30), 73% possible (22/30), and 23% definite (7/30) TAVI-IE. Adding 18F-FDG-PET/CT and CTA supported the reclassification of 10 of the 22 possible cases as “definite TAVI-IE” (5/22) or “rejected TAVI-IE” (5/22). This changed the final diagnosis to 20% rejected (6/30), 40% possible (12/30), and 40% definite (12/30) TAVI-IE. Conclusions: Addition of 18F-FDG-PET/CT and/or CTA changed the final diagnosis in 33% of patients and proved to be a valuable diagnostic tool in patients with suspected TAVI-IE
Serial cardiac biomarkers, pulmonary artery pressures and traditional parameters of fluid status in relation to prognosis in patients with chronic heart failure:Design and rationale of the BioMEMS study
AimsHeart failure (HF), a global pandemic affecting millions of individuals, calls for adequate predictive guidance for improved therapy. Congestion, a key factor in HF-related hospitalizations, further underscores the need for timely interventions. Proactive monitoring of intracardiac pressures, guided by pulmonary artery (PA) pressure, offers opportunities for efficient early-stage intervention, since haemodynamic congestion precedes clinical symptoms.MethodsThe BioMEMS study, a substudy of the MONITOR-HF trial, proposes a multifaceted approach integrating blood biobank data with traditional and novel HF parameters. Two additional blood samples from 340 active participants in the MONITOR-HF trial were collected at baseline, 3-, 6-, and 12-month visits and stored for the BioMEMS biobank. The main aims are to identify the relationship between temporal biomarker patterns and PA pressures derived from the CardioMEMS-HF system, and to identify the biomarker profile(s) associated with the risk of HF events and cardiovascular death.ConclusionSince the prognostic value of single baseline measurements of biomarkers like N-terminal pro-B-type natriuretic peptide is limited, with the BioMEMS study we advocate a dynamic, serial approach to better capture HF progression. We will substantiate this by relating repeated biomarker measurements to PA pressures. This design rationale presents a comprehensive review on cardiac biomarkers in HF, and aims to contribute valuable insights into personalized HF therapy and patient risk assessment, advancing our ability to address the evolving nature of HF effectively.Design and rationale of the BioMEMS study. QoL, quality of life. Graphical abstract is created with BioRender.com imag
Incidence, predictors and clinical impact of permanent pacemaker insertion in women following transcatheter aortic valve implantation: insights from a prospective multinational registry
To describe the incidence, predictors, and clinical impact of permanent pacemaker insertion (PPI) following transcatheter aortic valve replacement (TAVR) in women. Background: Data on pacemaker insertion complicating TAVR in women are scarce. Methods: The Women''s International Transcatheter Aortic Valve implantation (WIN-TAVI) is a prospective registry evaluating the safety and efficacy of TAVR in women. We included patients without preprocedural pacemakers and divided them into two groups: (1) PPI and (2) no-PPI. We identified PPI predictors using logistic regression and studied its clinical impact on the Valve Academic Research Consortium (VARC)-2 efficacy and safety endpoints. Results: Out of 1019 patients, 922 were included in the analysis. Post-TAVR PPI occurred in 132 (14.3%) patients. Clinical and procedural characteristics were similar in both groups. Pre-existing right bundle branch block (RBBB) was associated with a high risk of post-TAVR PPI (OR 3.62, 95% CI 1.85–7.06, p < 0.001), while implantation of balloon-expandable prosthesis was associated with a lower risk (OR 0.47, 95% CI 0.30–0.74, p < 0.001). Post-TAVR PPI prolonged in-hospital stay by a median of 2 days (11 [9–16] days in PPI vs. 9 [7–14] days in no-PPI, p = 0.005), yet risks of VARC-2 efficacy and safety endpoints at 1 year were similar in both groups (adjHR 0.95, 95% CI 0.60–1.52, p = 0.84 and adjHR 1.22, 95% CI 0.83–1.79, p = 0.31, respectively). Conclusion: Pacemaker implantation following TAVR is frequent among women and is associated with pre-existing RBBB and valve type. PPI prolongs hospital stay, albeit without any significant impact on 1-year outcomes
Use of a Repositionable and Fully Retrievable Aortic Valve in Routine Clinical Practice: The RESPOND Study and RESPOND Extension Cohort
Objectives: The authors sought to evaluate 1-year clinical outcomes with the Lotus valve (Boston Scientific, Marlborough, Massachusetts) in a large international, multicenter prospective registry including patients eligible for transcatheter aortic valve replacement (TAVR) based on heart team consensus. Background: TAVR is a safe and effective treatment for severe aortic valve stenosis; however, limited data are available on TAVR with the repositionable and fully retrievable Lotus valve in unrestricted contemporary clinical practice. Methods: The RESPOND (Repositionable Lotus Valve System—Post-Market Evaluation of Real World Clinical Outcomes) study enrolled 1,014 patients; 996 patients were implanted with the Lotus valve (mean age 80.8 years, 50.8% female, mean STS score 6.0 ± 6.9%). The primary endpoint was all-cause mortality in the intent-to-treat population at 30 days and 1 year. An Extension cohort of 50 patients was treated with the Lotus valve with Depth Guard including a modified delivery system. Mortality and stroke were independently adjudicated. An independent core laboratory assessed echocardiographic data. Results: One-year clinical follow-up was available for 99.9% of Lotus valve-treated patients. At 1 year, the all-cause mortality rate was 11.7% and 4.1% of patients had experienced a disabling stroke. The permanent pacemaker implantation rate was 32% (37% among pacemaker-naive patients). Echocardiographic data at 1 year were available for core laboratory assessment in 62.6% of patients. Paravalvular leak was absent or trace in 94.5%, mild in 5.1%, and moderate in 0.4% of patients. Data from the Extension cohort confirmed good clinical outcomes at 30 days with an 18% permanent pacemaker rate (20% among pacemaker-naive patients). Conclusions: One-year outcomes from the RESPOND study confirm the safety and efficacy of the Lotus valve when used in routine clinical practice. (Repositionable Lotus Valve System—Post-Market Evaluation of Real World Clinical Outcomes [RESPOND]; NCT02031302
Prevalence, predictors, and outcomes of patient prosthesis mismatch in women undergoing TAVI for severe aortic stenosis: Insights from the WIN-TAVI registry
Objective: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). Background: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. Methods: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry i
Serial cardiac biomarkers, pulmonary artery pressures and traditional parameters of fluid status in relation to prognosis in patients with chronic heart failure: Design and rationale of the BioMEMS study
AIMS: Heart failure (HF), a global pandemic affecting millions of individuals, calls for adequate predictive guidance for improved therapy. Congestion, a key factor in HF-related hospitalizations, further underscores the need for timely interventions. Proactive monitoring of intracardiac pressures, guided by pulmonary artery (PA) pressure, offers opportunities for efficient early-stage intervention, since haemodynamic congestion precedes clinical symptoms. METHODS: The BioMEMS study, a substudy of the MONITOR-HF trial, proposes a multifaceted approach integrating blood biobank data with traditional and novel HF parameters. Two additional blood samples from 340 active participants in the MONITOR-HF trial were collected at baseline, 3-, 6-, and 12-month visits and stored for the BioMEMS biobank. The main aims are to identify the relationship between temporal biomarker patterns and PA pressures derived from the CardioMEMS-HF system, and to identify the biomarker profile(s) associated with the risk of HF events and cardiovascular death. CONCLUSION: Since the prognostic value of single baseline measurements of biomarkers like N-terminal pro-B-type natriuretic peptide is limited, with the BioMEMS study we advocate a dynamic, serial approach to better capture HF progression. We will substantiate this by relating repeated biomarker measurements to PA pressures. This design rationale presents a comprehensive review on cardiac biomarkers in HF, and aims to contribute valuable insights into personalized HF therapy and patient risk assessment, advancing our ability to address the evolving nature of HF effectively
Prediction of paravalvular leakage after transcatheter aortic valve implantation
Significant paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) is related to patient mortality. Predicting the development of PVL has focused on computed tomography (CT) derived variables but literature targeting CoreValve devices is limited, controversial, and did not make use of standardized echocardiographic methods. The study included 164 consecutive patients with severe aortic stenosis that underwent TAVI with a Medtronic CoreValve system©, with available pre-TAVI CT and pre-discharge transthoracic echocardiography. The predictive value for significant PVL of the CT-derived Agatston score, aortic annulus size and eccentricity, and “cover index” was assessed, according to both echocardiographic Valve Academic Research Consortium (VARC) criteria and angiographic Sellers criteria. Univariate predictors for more than mild PVL were the maximal diameter of the aortic annulus size (for both angiographic and echocardiographic assessment of PVL), cover index (for echocardiographic assessment of PVL only), and Agatston score (for both angiographic and echocardiographic assessment of PVL). The aortic annulus eccentricity index was not predicting PVL. At multivariate analysis, Agatston score was the only independent predictor for both angiographic and echocardiographic assessment of PVL. Agatston score is the only independent predictor of PVL regardless of the used imaging technique for the definition of PVL
Clinical outcomes of state-of-the-art percutaneous coronary revascularization in patients with de novo three vessel disease: 1-year results of the SYNTAX II study
Aims: To investigate if recent technical and procedural developments in percutaneous coronary intervention (PCI) significantly influence outcomes in appropriately selected patients with three-vessel (3VD) coronary artery disease. Methods and results: The SYNTAX II study is a multicenter, all-comers, open-label, single arm study that investigated the impact of a contemporary PCI strategy on clinical outcomes in patients with 3VD in 22 centres from four European countries. The SYNTAX-II strategy includes: heart team decision-making utilizing the SYNTAX Score II (a clinical tool combining anatomical and clinical factors), coronary physiology guided revascularisation, implantation of thin strut bio-resorbable-polymer drug-eluting stents, intravascular ultrasound (IVUS) guided stent implantation, contemporary chronic total occlusion revascularisation techniques and guideline-directed medical therapy. The rate of major adverse cardiac and cerebrovascular events (MACCE [composite of all-cause death, cerebrovascular event, any myocardial infarction and any revascularisation]) at one year was compared to a predefined PCI cohort from the original SYNTAX-I trial selected on the basis of equipoise 4-year mortality between CABG and PCI. As an exploratory endpoint, comparisons were made with the historical CABG cohort of the original SYNTAX-I trial. Overall 708 patients were screened and discussed within the heart team; 454 patients were deemed appropriate to undergo PCI. At one year, the SYNTAX-II strategy was superior to the equipoise-derived SYNTAX-I PCI cohort (MACCE SYNTAX-II 10.6% vs. SYNTAX-I 17.4%; HR 0.58, 95% CI 0.39-0.85, P= 0.006). This difference was driven by a significant reduction in the incidence of MI (HR 0.27, 95% CI 0.11-0.70, P= 0.007) and revascularisation (HR 0.57, 95% CI 0.37-0.9, P = 0.015). Rates of all-cause death (HR 0.69, 95% CI 0.27-1.73, P = 0.43) and stroke (HR 0.69, 95% CI 0.10-4.89, P = 0.71) were similar. The rate of definite stent thrombosis was significantly lower in SYNTAX-II (HR 0.26, 95% CI 0.07-0.97, P = 0.045). Conclusion: At one year, clinical outcomes with the SYNTAX-II strategy were associated with improved clinical results compared to the PCI performed in comparable patients from the original SYNTAX-I trial. Longer term follow-up is awaited and a randomized clinical trial with contemporary CABG is warranted
- …