2,381 research outputs found
Testing "microscopic" theories of glass-forming liquids
We assess the validity of "microscopic" approaches of glass-forming liquids
based on the sole k nowledge of the static pair density correlations. To do so
we apply them to a benchmark provided by two liquid models that share very
similar static pair density correlation functions while disp laying distinct
temperature evolutions of their relaxation times. We find that the approaches
are unsuccessful in describing the difference in the dynamical behavior of the
two models. Our study is not exhausti ve, and we have not tested the effect of
adding corrections by including for instance three-body density correlations.
Yet, our results appear strong enough to challenge the claim that the slowd own
of relaxation in glass-forming liquids, for which it is well established that
the changes of the static structure factor with temperature are small, can be
explained by "microscopic" appr oaches only requiring the static pair density
correlations as nontrivial input.Comment: 10 pages, 7 figs; Accepted to EPJE Special Issue on The Physics of
Glasses. Arxiv version contains an addendum to the appendix which does not
appear in published versio
Coherent bremsstrahlung, boherent pair production, birefringence and polarimetry in the 20-170 GeV energy range using aligned crystals
The processes of coherent bremsstrahlung (CB) and coherent pair production
(CPP) based on aligned crystal targets have been studied in the energy range
20-170 GeV. The experimental arrangement allowed for measurements of single
photon properties of these phenomena including their polarization dependences.
This is significant as the theoretical description of CB and CPP is an area of
active theoretical debate and development. With the theoretical approach used
in this paper both the measured cross sections and polarization observables are
predicted very well. This indicates a proper understanding of CB and CPP up to
energies of 170 GeV. Birefringence in CPP on aligned crystals is applied to
determine the polarization parameters in our measurements. New technologies for
high energy photon beam optics including phase plates and polarimeters for
linear and circular polarization are demonstrated in this experiment. Coherent
bremsstrahlung for the strings-on-strings (SOS) orientation yields a larger
enhancement for hard photons than CB for the channeling orientations of the
crystal. Our measurements and our calculations indicate low photon
polarizations for the high energy SOS photons.Comment: 23 pages, 27 figures, 2 tables, REVTeX4 two column
Performance of the LHCb vertex locator
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 μm is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 μm for translations in the plane transverse to the beam. A primary vertex resolution of 13 μm in the transverse plane and 71 μm along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 μm is achieved for particles with transverse momentum greater than 1 GeV/c
Measurement of the proton and deuteron structure functions, F2p and F2d, and of the ratio sigma(L)/sigma(T)
The muon-proton and muon-deuteron inclusive deep inelastic scattering cross
sections were measured in the kinematic range 0.002 < x < 0.60 and 0.5 < Q2 <
75 GeV2 at incident muon energies of 90, 120, 200 and 280 GeV. These results
are based on the full data set collected by the New Muon Collaboration,
including the data taken with a small angle trigger. The extracted values of
the structure functions F2p and F2d are in good agreement with those from other
experiments. The data cover a sufficient range of y to allow the determination
of the ratio of the longitudinally to transversely polarised virtual photon
absorption cross sections, R= sigma(L)/sigma(T), for 0.002 < x < 0.12 . The
values of R are compatible with a perturbative QCD prediction; they agree with
earlier measurements and extend to smaller x.Comment: In this replacement the erroneously quoted R values in tables 3-6 for
x>0.12, and R1990 values in tables 5-6 for all x, have been corrected, and
the cross sections in tables 3-4 have been adapted. Everything else,
including the structure functions F2, remained unchanged. 22 pages, LateX,
including figures, with two .sty files, and three separate f2tab.tex files
for the F2-tables. Accepted for publication in Nucl.Phys.B 199
Precision luminosity measurements at LHCb
Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy √s. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for √s = 2.76, 7 and 8 TeV (proton-proton collisions) and for √sNN = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at √s = 8 TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determines the luminosity with a precision of 1.16%. This represents the most precise luminosity measurement achieved so far at a bunched-beam hadron collider
Initial microbial spectrum in severe secondary peritonitis and relevance for treatment
This study aims to determine whether abdominal microbial profiles in early severe secondary peritonitis are associated with ongoing infection or death. The study is performed within a randomized study comparing two surgical treatment strategies in patients with severe secondary peritonitis (n = 229). The microbial profiles of cultures retrieved from initial emergency laparotomy were tested with logistic regression analysis for association with ‘ongoing infection needing relaparotomy’ and in-hospital death. No microbial profile or the presence of yeast or Pseudomonas spp. was related to the risk of ongoing infection needing relaparotomy. Resistance to empiric therapy for gram positive cocci and coliforms was moderately associated with ongoing abdominal infection (OR 3.43 95%CI 0.95–12.38 and OR 7.61, 95%CI 0.75–76.94). Presence of only gram positive cocci, predominantly Enterococcus spp, was borderline independently associated with in-hospital death (OR 3.69, 95%CI 0.99–13.80). In secondary peritonitis microbial profiles do not predict ongoing abdominal infection after initial emergency laparotomy. However, the moderate association of ongoing infection with resistance to the empiric therapy compels to more attention for resistance when selecting empiric antibiotic coverage
Polarised Quark Distributions in the Nucleon from Semi-Inclusive Spin Asymmetries
We present a measurement of semi-inclusive spin asymmetries for positively
and negatively charged hadrons from deep inelastic scattering of polarised
muons on polarised protons and deuterons in the range 1
GeV. Compared to our previous publication on this subject, with the new
data the statistical errors have been reduced by nearly a factor of two.
From these asymmetries and our inclusive spin asymmetries we determine the
polarised quark distributions of valence quarks and non-strange sea quarks at
=10 GeV. The polarised valence quark distribution, , is positive and the polarisation increases with . The polarised
valence quark distribution, , is negative and the non-strange
sea distribution, , is consistent with zero over the measured
range of . We find for the first moments , and
, where we assumed
. We also determine for the first time the
second moments of the valence distributions .Comment: 17 page
The diagnostic work up of growth failure in secondary health care; An evaluation of consensus guidelines
Background: As abnormal growth might be the first manifestation of undetected diseases, it is important to have accurate referral criteria and a proper diagnostic work-up. In the present paper we evaluate the diagnostic work-up in secondary health care according to existing consensus guidelines and study the frequency of underlying medical disorders. Methods: Data on growth and additional diagnostic procedures were collected from medical records of new patients referred for short stature to the outpatient clinics of the general paediatric departments of two hospitals (Erasmus MC - Sophia Children's Hospital, Rotterdam and Spaarne Hospital, Haarlem) between January 1998 and December 2002. As the Dutch Consensus Guideline (DCG) is the only guideline addressing referral criteria as well as diagnostic work-up, the analyses were based on its seven auxological referral criteria to determine the characteristics of children who are incorrectly referred and the adequacy of workup of those who are referred. Results: Twenty four percent of children older than 3 years were inappropriately referred (NCR). Of the correctly referred children 74-88% were short corrected for parental height, 40-61% had a height SDS <-2.5 and 21% showed height deflection (Δ HSDS < -0.25/yr or Δ HSDS < -1). In none of the children a complete detailed routine diagnostic work up was performed and in more than 30% no routine laboratory examination was done at all. Pathologic causes of short stature were found in 27 children (5%). Conclusion: Existing guidelines for workup of children with suspected growth failure are poorly implemented. Although poorly implemented the DCG detects at least 5% pathologic causes of growth failure in children referred for short stature. New guidelines for referral are required with a better sensitivity and specificity, wherein distance to target height should get more attention. The general diagnostic work up for short stature should include testing for celiac disease in all children and for Turner syndrome in girls
Spin Structure of the Proton from Polarized Inclusive Deep-Inelastic Muon-Proton Scattering
We have measured the spin-dependent structure function in inclusive
deep-inelastic scattering of polarized muons off polarized protons, in the
kinematic range and . A
next-to-leading order QCD analysis is used to evolve the measured
to a fixed . The first moment of at is .
This result is below the prediction of the Ellis-Jaffe sum rule by more than
two standard deviations. The singlet axial charge is found to be . In the Adler-Bardeen factorization scheme, is
required to bring in agreement with the Quark-Parton Model. A
combined analysis of all available proton and deuteron data confirms the
Bjorken sum rule.Comment: 33 pages, 22 figures, uses ReVTex and smc.sty. submitted to Physical
Review
- …