138 research outputs found

    Endovenous treatments for varicose veins

    Get PDF
    Endovenous treatment is currently one of the most frequently used methods for treating varicose veins in the Netherlands. Varicose veins are tortuous and enlarged veins due to weakening in the vein’s wall or valves. They are manifestations of chronic venous disease (CVD), which may lead to serious complications

    Towards an individualized management strategy for patients with chronic venous disease: Results of a Delphi consensus

    Get PDF
    Objective: To obtain consensus on management criteria for symptomatic patients with chronic venous disease (CVD; C2–C6) and superficial venous reflux. Method: We used a Delphi method by means of 36 statements sent by email to experts in the field of phlebology across the world over the course of three rounds. The statements addressed criteria for different venous treatments in patients with different characteristics (e.g. extensive comorbidities, morbid obesity and peripheral arterial disease). If at least 70% of the ratings for a specific statement were between 6 and 9 (agreement) or between 1 and 3 (disagreement), experts’ consensus was reached. Results: Twenty-five experts were invited to participate, of whom 24 accepted and completed all three rounds. Consensus was reached in 25/32 statements (78%). However, several statements addressing UGFS, single phlebectomies, patients with extensive comorbidities and morbid obesity remained equivocal. Conclusion: Considerable consensus was reached within a group of experts but also some gaps in available research were highlighted

    Process evaluation of a multicentre randomised clinical trial of substituting surgical excisions of low-risk basal cell carcinomas from secondary to primary care

    Get PDF
    OBJECTIVES: In 2016, the SKINCATCH Trial, a clustered multi-centre randomised trial, was initiated to assess whether low-risk basal cell carcinomas (BCCs) can be treated by general practitioners (GPs) without loss of quality of care. The trial intervention consisted of a tailored 2-day educational course on skin cancer management. The aim of this process evaluation was to investigate GPs’ exposure to the intervention, implementation of the intervention and experiences with the intervention and trial. RESEARCH DESIGN AND METHODS: Data on exposure to the intervention, implementation and experiences were obtained at several points during the trial. Complementary quantitative components (ie, surveys, database analysis, medical record analysis) and qualitative components (ie, interviews and focus groups) were used. Quantitative data were analysed using descriptive statistics; qualitative data were summarised (barrier interviews) or audiorecorded, transcribed verbatim and thematically analysed using Atlas.Ti (focus groups). RESULTS: Following a 100% intervention exposure, results concerning the implementation of the trial showed that aside from the low inclusion rate of patients with low-risk BCCs (n=54), even less excisions of low-risk BCCs were performed (n=40). Although the intervention was experienced as highly positive, several barriers were mentioned regarding the trial including administrative challenges, lack of time and high workload of GPs, low volume of BCC patients and patients declining to participate or requesting a referral to a dermatologist. CONCLUSIONS: Although GPs’ participation in the highly valued training was optimal, several barriers may have contributed to the low inclusion and excision rate of low-risk BCCs. While some of the issues were trial-related, other barriers such as low patient-volume and patients requesting referrals are applicable outside the trial setting as well. This may question the feasibility of substitution of surgical excisions of low-risks BCCs from secondary to primary care in the current Dutch setting. TRIAL REGISTRATION NUMBER: Trial NL5631 (NTR5746)

    Carbonized blood deposited on fibres during 810, 940 and 1,470 nm endovenous laser ablation: thickness and absorption by optical coherence tomography

    Get PDF
    Endovenous laser ablation (EVLA) is commonly used to treat saphenous varicosities. Very high temperatures at the laser fibre tip have been reported during EVLA. We hypothesized that the laser irradiation deposits a layer of strongly absorbing carbonized blood of very high temperature on the fibre tip. We sought to prove the existence of these layers and study their properties by optical transmission, optical coherence tomography (OCT) and microscopy. We analysed 23 EVLA fibres, 8 used at 810 nm, 7 at 940 nm and 8 at 1,470 nm. We measured the transmission of these fibres in two wavelength bands (450–950 nm; 950–1,650 nm). We used 1,310 nm OCT to assess the thickness of the layers and the attenuation as a function of depth to determine the absorption coefficient. Microscopy was used to view the tip surface. All fibres showed a slightly increasing transmission with wavelength in the 450–950 nm band, and a virtually wavelength-independent transmission in the 950–1,650 nm band. OCT scans showed a thin layer deposited on all 13 fibres investigated, 6 used at 810 nm, 4 at 940 nm and 3 at 1,470 nm, some with inhomogeneities over the tip area. The average absorption coefficient of the 13 layers was 72 ± 16 mm−1. The average layer thickness estimated from the transmission and absorption measurements was 8.0 ± 2.7 µm. From the OCT data, the average maximal thickness was 26 ± 6 µm. Microscopy of three fibre tips, one for each EVLA wavelength, showed rough, cracked and sometimes seriously damaged tip surfaces. There was no clear correlation between the properties of the layers and the EVLA parameters such as wavelength, except for a positive correlation between layer thickness and total delivered energy. In conclusion, we found strong evidence that all EVLA procedures in blood filled veins deposit a heavily absorbing hot layer of carbonized blood on the fibre tip, with concomitant tip damage. This major EVLA mechanism is unlikely to have much wavelength dependence at similar delivered energies per centimetre of vein. Optical–thermal interaction between the vein wall and the transmitted laser light depends on wavelength

    Quality of Life after Venous Stenting for Post-thrombotic Syndrome and the Effect of Inflow Disease

    Get PDF
    Objective: Patients with PTS experience an impaired quality of life (QoL). We aimed to study QoL in patients stented for post thrombotic syndrome (PTS) and analyze the influence of different parameters. Methods: Patients stented for PTS after iliofemoral deep vein thrombosis were asked to complete the Chronic Venous Disease Quality of Life Questionnaire (CIVIQ-20) and the Short Form Health Survey (SF-36) in this cross-sectional study. All other data were collected retrospectively. Primary endpoints were median CIVIQ-20 and physical (PCS) and mental (MCS) component summary SF-36 scores. The influence of age, sex, and years between the procedure and completion of questionnaire were investigated using a multivariate linear regression model. Wilcoxon signed rank test compared the PCS and MCS with the normative. Effects of inflow from the deep femoral vein (DFV) and/or the femoral vein (FV) on QoL was analyzed in patients with patent stents. Results: The response rate was 70.3% (n = 45/64). Time period (median) from stenting to questionnaire completion was 6.6 years (IQR: 8.0). Most stents were placed unilateral left-sided (73.3%). For patients with patent stents (n = 42) median CIVIQ-20 was 35.5 (IQR: 17.3), higher than the minimum of 20.0 (P < .001). Median PCS of 44.7 (IQR: 14.2) was lower (P < .001), and MCS of 55.9 (IQR: 7.1) higher (P = .001) than the normative (50.0). Time since stenting and sex were not associated with QoL. Age was a significant predictor [standardized coefficient ss = .36, P = .04] for QoL using the CIVIQ-20, but not for the SF-36. Inflow disease did not impact QoL, but patients with occluded stents (n = 3) had poor functioning levels. Conclusion: Quality of life is impaired after venous stenting for PTS, particularly physical functioning, among patients with an open stent, but was similar between patients with good and impaired inflow. Patients with a permanent stent occlusion had the lowest QoL

    Quality of Life after Venous Stenting for Post-thrombotic Syndrome and the Effect of Inflow Disease

    Get PDF
    Objective: Patients with PTS experience an impaired quality of life (QoL). We aimed to study QoL in patients stented for post thrombotic syndrome (PTS) and analyze the influence of different parameters. Methods: Patients stented for PTS after iliofemoral deep vein thrombosis were asked to complete the Chronic Venous Disease Quality of Life Questionnaire (CIVIQ-20) and the Short Form Health Survey (SF-36) in this cross-sectional study. All other data were collected retrospectively. Primary endpoints were median CIVIQ-20 and physical (PCS) and mental (MCS) component summary SF-36 scores. The influence of age, sex, and years between the procedure and completion of questionnaire were investigated using a multivariate linear regression model. Wilcoxon signed rank test compared the PCS and MCS with the normative. Effects of inflow from the deep femoral vein (DFV) and/or the femoral vein (FV) on QoL was analyzed in patients with patent stents. Results: The response rate was 70.3% (n = 45/64). Time period (median) from stenting to questionnaire completion was 6.6 years (IQR: 8.0). Most stents were placed unilateral left-sided (73.3%). For patients with patent stents (n = 42) median CIVIQ-20 was 35.5 (IQR: 17.3), higher than the minimum of 20.0 (P &lt;.001). Median PCS of 44.7 (IQR: 14.2) was lower (P &lt;.001), and MCS of 55.9 (IQR: 7.1) higher (P =.001) than the normative (50.0). Time since stenting and sex were not associated with QoL. Age was a significant predictor [standardized coefficient ß =.36, P =.04] for QoL using the CIVIQ-20, but not for the SF-36. Inflow disease did not impact QoL, but patients with occluded stents (n = 3) had poor functioning levels. Conclusion: Quality of life is impaired after venous stenting for PTS, particularly physical functioning, among patients with an open stent, but was similar between patients with good and impaired inflow. Patients with a permanent stent occlusion had the lowest QoL.</p

    The heat-pipe resembling action of boiling bubbles in endovenous laser ablation

    Get PDF
    Endovenous laser ablation (EVLA) produces boiling bubbles emerging from pores within the hot fiber tip and traveling over a distal length of about 20 mm before condensing. This evaporation-condensation mechanism makes the vein act like a heat pipe, where very efficient heat transport maintains a constant temperature, the saturation temperature of 100°C, over the volume where these non-condensing bubbles exist. During EVLA the above-mentioned observations indicate that a venous cylindrical volume with a length of about 20 mm is kept at 100°C. Pullback velocities of a few mm/s then cause at least the upper part of the treated vein wall to remain close to 100°C for a time sufficient to cause irreversible injury. In conclusion, we propose that the mechanism of action of boiling bubbles during EVLA is an efficient heat-pipe resembling way of heating of the vein wall
    • …
    corecore