139 research outputs found

    Feasibility and patient’s experiences of perioperative telemonitoring in major abdominal surgery:an observational pilot study

    Get PDF
    Background: Telemonitoring during the perioperative trajectory may improve patient outcomes and self-management. The aim of this study is to assess the feasibility of and patient’s experiences with telemonitoring before and after major abdominal surgery to inform future study design. Methods: Patients planned for elective major abdominal surgery wore a sensor and answered well-being questions on a tablet daily for at least 2 weeks preoperatively up to 30-days postoperatively. Feasibility was assessed by participation and completion rate, compliance per day, weekly satisfaction scores, and reasons for nonscheduled contact. Results: Twenty-three patients were included (participation rate of 54.5%) with a completion rate of 69.6%. Median compliance with the wearable sensor and well-being questions was respectively: 94.7% and 83.3% preoperatively at home; 100% and 66.7% postoperatively in-hospital; and 95.4% and 85.8% postoperatively at home. Median weekly satisfaction scores for both wearing the sensor and well-being questions were 5 (IQR, 4–5). Contact moments were related to absence of sensor data and technological issues (76.0%) or patient discomfort and insecurity (24.0%). Conclusions: In this study, telemonitoring showed high satisfaction and compliance during the perioperative trajectory. Future trial design regarding the effectiveness of telemonitoring requires embedding in clinical practice and support for patients, relatives, and healthcare personnel

    The Validity of Teacher Rating Scales for the Assessment of ADHD Symptoms in the Classroom:A Systematic Review and Meta-Analysis

    Get PDF
    Objective: To assess attention-deficit/hyperactivity disorder (ADHD) symptoms in the classroom, most often teacher rating scales are used. However, clinical interviews and observations are recommended as gold standard assessment. This systematic review and meta-analysis evaluates the validity of teacher rating scales. Method: Twenty-two studies (N = 3,947 children) assessing ADHD symptoms using teacher rating scale and either semi-structured clinical interview or structured classroom observation were meta-analyzed. Results: Results showed convergent validity for rating scale scores, with the strongest correlations (r =.55–.64) for validation against interviews, and for hyperactive–impulsive behavior. Divergent validity was confirmed for teacher ratings validated against interviews, whereas validated against observations this was confirmed for inattention only. Conclusion: Teacher rating scales appear a valid and time-efficient measure to assess classroom ADHD; although validated against semi-structured clinical interviews, there were only a few studies available. Low correlations between ratings and structured observations of inattention suggest that observations could add information above rating scales

    Continuous monitoring of vital signs with the Everion biosensor on the surgical ward:a clinical validation study

    Get PDF
    Background: Wearable sensors enable continuous vital sign monitoring, although information about their performance on nursing wards is scarce. Vital signs measured by telemonitoring and nurse measurements on a surgical ward were compared to assess validity and reliability. Methods: In a prospective observational study, surgical patients wore a wearable sensor (Everion, Biovotion AG, Zürich, Switzerland) that continuously measured heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), and temperature during their admittance on the ward. Validity was evaluated using repeated-measures correlation and reliability using Bland-Altman plots, mean difference, and 95% limits of agreement (LoA). Results: Validity analyses of 19 patients (median age, 68; interquartile range, 62.5–72.5 years) showed a moderate relationship between telemonitoring and nurse measurements for HR (r = 0.53; 95% confidence interval, 0.44–0.61) and a poor relationship for RR, SpO2, and temperature. Reliability analyses showed that Everion measured HR close to nurse measurements (mean difference, 1 bpm; LoA, −16.7 to 18.7 bpm). Everion overestimated RR at higher values, whereas SpO2 and temperature were underestimated. Conclusions: A moderate relationship was determined between Everion and nurse measurements at a surgical ward in this study. Validity and reliability of telemonitoring should also be assessed with gold standard devices in future clinical trials

    Continuous Monitoring of Vital Signs With Wearable Sensors During Daily Life Activities:Validation Study

    Get PDF
    BACKGROUND: Continuous telemonitoring of vital signs in a clinical or home setting may lead to improved knowledge of patients’ baseline vital signs and earlier detection of patient deterioration, and it may also facilitate the migration of care toward home. Little is known about the performance of available wearable sensors, especially during daily life activities, although accurate technology is critical for clinical decision-making. OBJECTIVE: The aim of this study is to assess the data availability, accuracy, and concurrent validity of vital sign data measured with wearable sensors in volunteers during various daily life activities in a simulated free-living environment. METHODS: Volunteers were equipped with 4 wearable sensors (Everion placed on the left and right arms, VitalPatch, and Fitbit Charge 3) and 2 reference devices (Oxycon Mobile and iButton) to obtain continuous measurements of heart rate (HR), respiratory rate (RR), oxygen saturation (SpO(2)), and temperature. Participants performed standardized activities, including resting, walking, metronome breathing, chores, stationary cycling, and recovery afterward. Data availability was measured as the percentage of missing data. Accuracy was evaluated by the median absolute percentage error (MAPE) and concurrent validity using the Bland-Altman plot with mean difference and 95% limits of agreement (LoA). RESULTS: A total of 20 volunteers (median age 64 years, range 20-74 years) were included. Data availability was high for all vital signs measured by VitalPatch and for HR and temperature measured by Everion. Data availability for HR was the lowest for Fitbit (4807/13,680, 35.14% missing data points). For SpO(2) measured by Everion, median percentages of missing data of up to 100% were noted. The overall accuracy of HR was high for all wearable sensors, except during walking. For RR, an overall MAPE of 8.6% was noted for VitalPatch and that of 18.9% for Everion, with a higher MAPE noted during physical activity (up to 27.1%) for both sensors. The accuracy of temperature was high for VitalPatch (MAPE up to 1.7%), and it decreased for Everion (MAPE from 6.3% to 9%). Bland-Altman analyses showed small mean differences of VitalPatch for HR (0.1 beats/min [bpm]), RR (−0.1 breaths/min), and temperature (0.5 °C). Everion and Fitbit underestimated HR up to 5.3 (LoA of −39.0 to 28.3) bpm and 11.4 (LoA of −53.8 to 30.9) bpm, respectively. Everion had a small mean difference with large LoA (−10.8 to 10.4 breaths/min) for RR, underestimated SpO(2) (>1%), and overestimated temperature up to 2.9 °C. CONCLUSIONS: Data availability, accuracy, and concurrent validity of the studied wearable sensors varied and differed according to activity. In this study, the accuracy of all sensors decreased with physical activity. Of the tested sensors, VitalPatch was found to be the most accurate and valid for vital signs monitoring

    Telemedicine in patients with peripheral arterial disease:is it worth the effort?

    Get PDF
    Introduction: For patients with peripheral arterial disease (PAD), the various components of telemedicine, such as telemonitoring, telecoaching, and teleconsultation, could be valuable in daily management. The objective of this review was to give an overview of the current use of telemedicine interventions in PAD. Areas covered: A literature search was performed for studies that evaluated patients with PAD of the aorto-pedal trajectory, who were monitored by telemedicine and acted upon accordingly. The primary outcome was health-related outcomes. The studies that were found focused mainly on wearable activity monitoring and telecoaching in PAD (n = 4) or wound monitoring after vascular surgery (n = 2). Main results indicate that telemedicine interventions are able to detect (post-operative) complications early, improve functional capacity and claudication onset time, and improve PAD patients’ quality of life. Expert opinion: The use of telemedicine in PAD patients is still an under-explored area. Studies investigating the use of telemedicine in PAD are very limited and show varying results. Owing to its high potential in improving physical ability, lifestyle coaching, and timely detection of deterioration, future research should focus on proper implementation of telemedicine in PAD patients, including clinical and feasibility outcomes, effect on workload of nurses, and cost-efficiency.</p

    Impact of rituximab biosimilars on overall survival in diffuse large B-cell lymphoma:a Dutch population-based study

    Get PDF
    In 2017, the European Medicines Agency approved rituximab biosimilars (R-biosimilars) for treatment of diffuse large B-cell lymphoma (DLBCL). Thereafter, the Netherlands was one of the first countries to implement R-biosimilars, given lower costs compared with rituximab originator (R-originator). This study's objective was to investigate whether overall survival (OS) of patients with DLBCL receiving R-biosimilars is similar to patients treated with R-originator. DLBCL patients ≥18 years, diagnosed between 2014 and 2018, who received at least 1 cycle of rituximab combined with cyclophosphamide, doxorubicin, vincristine, and prednisolone (R-CHOP) were identified in the Netherlands Cancer Registry. Patients were categorized into R-originator or R-biosimilars groups based on data from a central repository of the Dutch medicinal drug market. The primary end point was 3-year OS, defined as the time between diagnosis and all-cause death. By the end of 2018, 91% of purchased rituximab were biosimilars. In total, 4429 patients were identified with 876 in the R-biosimilars group and 3553 in the R-originator group. Patients in the R-biosimilars group less frequently received .6 cycles of R-CHOP compared with patients treated with R-originator (24% vs 30%, P 5 .003). The 3-year OS did not differ between patients treated with R-originator or R-biosimilars (73% vs 73%, P = .855). This was confirmed with a multivariable Cox regression analysis accounting for sex, age, International Prognostic Index score, and number of R-CHOP cycles. In conclusion, the 3-year OS is similar for patients treated with CHOP in combination with R-originator or R-biosimilars and, therefore, favors the use of R-biosimilars in DLBCL treatment management

    CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes

    Get PDF
    PURPOSE: The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. MATERIALS AND METHODS: One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7 50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4 50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. RESULTS: The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% in group 2 (p = 0.749). Mean per-polyp sensitivity for lesions >or=10 mm was 86% in group 1 and 97% in group 2 (p = 0.355). Patient burden from diarrhoea significantly decreased for patients in group 2. CONCLUSIONS: One-day preparation with meglumine ioxithalamate results in an improved patient acceptability compared with 2-day preparation and has a comparable, excellent image quality and good diagnostic performanc

    Case Report A Girl with Autoimmune Cytopenias, Nonmalignant Lymphadenopathy, and Recurrent Infections

    Get PDF
    We describe a girl, now 9 years of age, with chronic idiopathic thrombocytopenic purpura, persistent nonmalignant lymphadenopathy, splenomegaly, recurrent infections, and autoimmune hemolytic anemia. Her symptoms partly fit the definitions of both autoimmune lymphoproliferative syndrome (ALPS) and common variable immunodeficiency disorders (CVIDs). Genetic analysis showed no abnormalities in the ALPS-genes FAS, FASLG, and CASP10. The CVID-associated TACI gene showed a homozygous polymorphism (Pro251Leu), which is found also in healthy controls

    De-escalation of axillary treatment in the event of a positive sentinel lymph node biopsy in cT1-2 N0 breast cancer treated with mastectomy:nationwide registry study (BOOG 2013-07)

    Get PDF
    Background: Trials have demonstrated the safety of omitting completion axillary lymph node dissection in patients with cT1-2 N0 breast cancer operated with breast-conserving surgery who have limited metastatic burden in the sentinel lymph node. The aim of this registry study was to provide insight into the oncological safety of omitting completion axillary treatment in patients operated with mastectomy who have limited-volume sentinel lymph node metastasis. Methods: Women diagnosed in 2013-2014 with unilateral cT1-2 N0 breast cancer treated with mastectomy, with one to three sentinel lymph node metastases (pN1mi-pN1a), were identified from the Netherlands Cancer Registry, and classified by axillary treatment: no completion axillary treatment, completion axillary lymph node dissection, regional radiotherapy, or completion axillary lymph node dissection followed by regional radiotherapy. The primary endpoint was 5-year regional recurrence rate. Secondary endpoints included recurrence-free interval and overall survival, among others. Results: In total, 1090 patients were included (no completion axillary treatment, 219 (20.1%); completion axillary lymph node dissection, 437 (40.1%); regional radiotherapy, 327 (30.0%); completion axillary lymph node dissection and regional radiotherapy, 107 (9.8%)). Patients in the group without completion axillary treatment had more favourable tumour characteristics and were older. The overall 5-year regional recurrence rate was 1.3%, and did not differ significantly between the groups. The recurrence-free interval was also comparable among groups. The group of patients who did not undergo completion axillary treatment had statistically significantly worse 5-year overall survival, owing to a higher percentage of non-cancer deaths. Conclusion:In this registry study of patients with cT1-2 N0 breast cancer treated with mastectomy, with low-volume sentinel lymph node metastasis, the 5-year regional recurrence rate was low and comparable between patients with and without completion axillary treatment.</p

    De-escalation of axillary treatment in the event of a positive sentinel lymph node biopsy in cT1-2 N0 breast cancer treated with mastectomy:nationwide registry study (BOOG 2013-07)

    Get PDF
    Background: Trials have demonstrated the safety of omitting completion axillary lymph node dissection in patients with cT1-2 N0 breast cancer operated with breast-conserving surgery who have limited metastatic burden in the sentinel lymph node. The aim of this registry study was to provide insight into the oncological safety of omitting completion axillary treatment in patients operated with mastectomy who have limited-volume sentinel lymph node metastasis. Methods: Women diagnosed in 2013-2014 with unilateral cT1-2 N0 breast cancer treated with mastectomy, with one to three sentinel lymph node metastases (pN1mi-pN1a), were identified from the Netherlands Cancer Registry, and classified by axillary treatment: no completion axillary treatment, completion axillary lymph node dissection, regional radiotherapy, or completion axillary lymph node dissection followed by regional radiotherapy. The primary endpoint was 5-year regional recurrence rate. Secondary endpoints included recurrence-free interval and overall survival, among others. Results: In total, 1090 patients were included (no completion axillary treatment, 219 (20.1%); completion axillary lymph node dissection, 437 (40.1%); regional radiotherapy, 327 (30.0%); completion axillary lymph node dissection and regional radiotherapy, 107 (9.8%)). Patients in the group without completion axillary treatment had more favourable tumour characteristics and were older. The overall 5-year regional recurrence rate was 1.3%, and did not differ significantly between the groups. The recurrence-free interval was also comparable among groups. The group of patients who did not undergo completion axillary treatment had statistically significantly worse 5-year overall survival, owing to a higher percentage of non-cancer deaths. Conclusion:In this registry study of patients with cT1-2 N0 breast cancer treated with mastectomy, with low-volume sentinel lymph node metastasis, the 5-year regional recurrence rate was low and comparable between patients with and without completion axillary treatment.</p
    • …
    corecore