17 research outputs found
Bonding agent underneath sealant: shear bond strength to oil-contaminated
This study evaluated in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with either an ethanol-based (Adper Single Bond 2 - SB) or an acetone-based (Prime & Bond - PB) adhesive system under conditions of oil contamination. Mesial and distal enamel surfaces from 30 sound third molars were randomly assigned to 2 groups (n=30): I - no oil contamination; II - oil contamination. Contamination (0.25 mL during 10 s) was performed after 37% phosphoric acid etching with an air/oil spray. The specimens were randomly assigned to subgroups, according to the bonding protocol adopted: subgroup A - F was applied to enamel without an intermediate bonding agent layer; In subgroups B and C, SB and PB, respectively, were applied, light-cured, and then F was applied and light-cured. Shear bond strength was tested at a crosshead speed of 0.5 mm/min in a universal testing machine. Means (± SD) in MPa were: IA-11.28 (±1.84); IIA-12.02 (±1.15); IB-9.73 (±2.38); IIB-9.62 (±2.29); IC-28.30 (±1.63); and IIC-25.50 (±1.91). It may be concluded that the oil contamination affected negatively the sealant bonding to enamel and the acetone-based adhesive system (PB) layer applied underneath the sealant was able to prevent its deleterious effects to adhesion.Este estudo avaliou in vitro a resistência ao cisalhamento (RC) de um selante resinoso [Fluroshield (F); Dentsply/Caulk] em associação com um sistema adesivo com solvente a base de etanol [Adper Single Bond 2 (SB); 3M/ESPE] ou a base de acetona [Prime & Bond (PB); 3M/ESPE] após contaminação com óleo do esmalte. Superfícies mesiais e distais de esmalte de 30 terceiros molares hígidos foram aleatoriamente alocadas em 2 grupos (n=30): I - contaminação com óleo; II - sem contaminação. A contaminação foi realizada (0,25 mL;10 s) com um jato de ar/óleo após o condicionamento do esmalte com ácido fosfórico a 37%. Os espécimes foram aleatoriamente alocados em subgrupos, de acordo com a técnica adesiva empregada: A - F foi aplicado sobre o esmalte condicionado sem sistema adesivo; B - SB + F; C - PB + F. RC foi testada em uma máquina universal de ensaios (0,5 mm/min; 50 kgf) e os dados analisados por ANOVA e t-teste (α=0,01). As médias de RC em MPa foram: IA-11,28 (±1,84); IIA-12,02(±1,15); IB-9,73 (±2,38); IIB-9,62 (±2,29); IC-28,30 (±1.63); e IIC-25,50 (±1,91). Conclui-se que a contaminação com o óleo afetou a adesão do selante resinoso ao esmalte e o sistema adesivo com solvente a base de acetona (Prime & Bond) aplicado sob o selante foi capaz de impedir os efeitos deletérios da contaminação com óleo
Crown dilaceration in permanent teeth after trauma to the primary predecessors: report of three cases
Crown dilaceration of permanent teeth occurs due to the non-axial displacement of the already formed hard tissue portion of the developing crown at an angle to their longitudinal axis due to trauma to the primary predecessors. This is a rare condition, representing only 3% of the total of injuries to developing teeth and usually occurs in permanent maxillary incisors because of the close proximity of their tooth germs to the primary incisors, which are more susceptible to trauma. This alteration frequently results from the intrusion of a primary tooth when the child is around 2 years of age, at which time half of the crown of the permanent successor is already formed. Teeth with dilacerated crowns may either erupt with buccal or lingual displacement or remain impacted. The treatment may involve endodontic, orthodontic, restorative and prosthetic procedures. This paper reports the restorative treatment proposed to reestablish the esthetics and function of the affected teeth in three cases of crown dilaceration in permanent maxillary incisors after trauma to their primary predecessors
Influence of cobalto-60 irradiation on the mechanical, chemical and morphological properties of enamel and dentin of primary teeth an in vitro study
O objetivo do presente estudo foi avaliar, in vitro, os efeitos da irradiação com cobalto-60 (Co 60), nas propriedades do esmalte e da dentina de dentes decíduos por meio da: 1 - microdureza longitudinal; 2 - morfologia em microscopia eletrônica de varredura (MEV); e 3 - composição química em espectroscopia de energia dispersiva de raios X (EDX). No primeiro experimento foi avaliada a microdureza do esmalte e da dentina (n=12 hemissecções vestibulares) em 3 profundidade (superficial, média e profunda), antes e a cada 10 Gy de irradiação, até uma dose cumulativa total de 60 Gy. No segundo experimento foi avaliada a morfologia do esmalte e da dentina por meio de MEV (n=8 hemissecções), sendo 2 hemissecções vestibulares irradiadas com a dose cumulativa de 30 Gy, 2 hemissecções vestibulares irradiadas com a dose cumulativa de 60 Gy e 4 hemissecções palatinas não irradiadas. No terceiro experimento, identificou-se os elementos químicos do esmalte e da dentina por meio de EDX (n=4 hemissecções), utilizando-se as mesmas hemissecções previamente submetidas à MEV (com a dose cumulativa de 60 Gy de irradiação e nas hemissecções não irradiadas). No primeiro experimento a microdureza, antes e após, a irradiação, foi avaliada na mesma hemissecção dental (face vestibular). Já no segundo e terceiro experimentos, as hemissecções vestibulares foram submetidas à irradiação e as hemissecções palatinas do mesmo dente funcionaram como controle. Os dados foram analisados quanto à sua distribuição e submetidos à Análise de Variância a dois critérios. Para a diferenciação das médias, empregou-se o teste de Fisher. O nível de significância adotado foi de 5%. A microdureza longitudinal no esmalte, como um todo, variou após as diferentes doses de irradiação, aumentando significantemente após a dose de 60 Gy (p0,05). Observou-se que na dentina média foi encontrado o maior valor médio de microdureza (29,9 KH), o qual foi estatisticamente diferente (p0.05). The highest mean value of microhardness was obtained in the middle dentin (29.9 KH), which was significantly different (p<0.05) from the other analyzed regions. The morphological analysis of enamel and dentin revealed that the groups irradiated with doses of 30 Gy and 60 Gy presented greater surface alterations compared with non-irradiated specimens at all analyzed regions. The chemical analysis of irradiated enamel and dentin compared with non-irradiated specimens revealed a decrease of oxygen and an increase of calcium. In conclusion, irradiation of primary teeth with Co-60 influenced the longitudinal microhardness of enamel and dentin, according to the dose and irradiated region. In enamel as a whole, microhardness increased with the cumulative dose of 60 Gy, regardless of the analyzed region. In dentin, there was no change in the microhardness mean values after irradiation, regardless of the analyzed region. The analysis of morphology revealed that, the increase of the irradiation dose resulted in enamel and dentin disorganization, which presented an amorphous surface with difficulty in identifying enamel prisms and dentin tubules, respectively. The chemical analysis revealed a decrease in the percentage of oxygen and an increase in the percentage of calcium in irradiated enamel and dentin
Adhesion of different adhesive systems to the enamel and dentin of primary teeth that have undergone radiotherapy
A radioterapia (RT), quando aplicada na região de cabeça e pescoço, pode ocasionar alterações estruturais no esmalte e na dentina que poderiam influenciar o comportamento dos sistemas adesivos. O presente estudo teve como objetivo avaliar a influência da RT na adesão dos sistemas adesivos (Clearfil SE Bond e Adper™ Single Bond 2) ao esmalte (E) e à dentina (D) de dentes decíduos, em diferentes tempos (antes e após a RT). Foram utilizados 60 molares decíduos seccionados obtendo um total de 120 fragmentos de esmalte e 120 de dentina que, após o preparo da superfície, foram divididos aleatoriamente em 4 grupos (n=30/grupo): G1 (controle) - esmalte/dentina sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT, G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo no subgrupo A empregado o sistema adesivo etch-rinse Adper™ Single Bond 2; e no subgrupo B o adesivo self-etch Clearfil SE Bond. Os espécimes foram irradiados com fração de dose de 2 Gy, por 5 dias consecutivos, até atingir a dose total de 60 Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentasse 4 mm de altura e 2 mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento (célula de carga 50 kgf e velocidade 0,5 mm/minuto) obtendo-se o resultado em N, o qual foi transformado em MPa. A análise do padrão de fratura foi realizada em microscopia confocal (MC). Foram selecionados 5 espécimes de esmalte e 5 espécimes de dentina, para realização da análise morfológica da superfície dental por meio de microscopia confocal, sendo estes avaliados a cada 10 Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para análise em microscopia eletrônica de varredura (MEV). O esmalte e a dentina foram analisados separadamente, sendo os dados analisados por ANOVA a 2 critérios e pós- teste de tukey (p0,05). O tipo de fratura predominante foi adesiva, que aumentou a predominância com a irradiação. Na análise em MC houve alterações morfológicas em esmalte e dentina após a dose cumulativa de 40 Gy. Em MEV observou-se a alterações na formação de tags e de camada híbrida. Pôde-se concluir que a radioterapia alterou a morfologia da superfície do esmalte e da dentina, e afetou a adesão dos sistemas adesivos, sendo necessário esperar pelo menos 6 meses para a realização dos procedimentos restauradores, tendo o sistema Clearfil SE Bond menos influenciado.When radiotherapy (RT) is performed in the head and neck region, it could lead to structural alteration in enamel and dentin that could influence the behavior of the bonding agents. The present study aimed to evaluate whether the RT interferes in the bonding o two adhesive systems (Clearfil SE Bond e AdperTM Single Bond 2) to enamel (E) and dentin (D) of primary teeth, in different times (before and after RT). Sixty primary molars were cut in a total of 120 fragments of enamel and 120 of dentin, which after the surface polishing were randomly divided into 4 groups (n=30/group): G1 (control) - enamel and dentin without RT + restorative procedures; G2 - restorative procedures performed before RT; G3 - restorative procedures performed after RT; and G4 - restorative procedures performed 6 months after RT. Each one of the groups was then divided into 2 subgroups: subgroup A using the etch-rinse Adper™ Single Bond 2; and subgroup B using the self-etch Clearfil SE Bond. The specimens were irradiated in dose fractions of 2 Gy, for 5 consecutive days, until reaching the final dose of 60Gy, in a total of 30 fractions, during 6 weeks. The restorative procedures were done using the Z350 composite, and for standardization of the restorations a matrix was used, so the specimens all presented 4 mm height and 2 mm of diameter. The specimens were submitted to the shear bond strength test (load of 50 kgf and speed of 0.5 mm/minute), the result was obtained in N and then transformed to Mpa. The fracture pattern was analyzed in a confocal microscopy (MC). Five specimens of enamel and 5 of dentin were chosen to the morphological analyzes also by MC, those specimens were evaluated every 10 Gy. As for the bonding interface 3 specimens of each group were chosen, and prepared for scanning electron microscopy (SEM). Enamel and dentin were evaluated separately, data was analyzed by the ANOVA and Post Test Tukey (p<0.05). Significance level was 5%. It could be observed that for both substrates the Clearfil SE Bond (E: 20.19 MPa; D: 17.61 MPa) was statically superior than Single Bond (E: 17.21 MPa; D: 15.45 MPa) (p<0.05). As for the time of restoration, group 2 had the worst results, in both enamel and dentin. It was observed that that radiation affected negatively the bonding in enamel and dentin (p<0.05), however, in the group 4 no alterations were observed (p<0.05). The predominant fracture pattern was the adhesive, which had raised its prevalence according to the radiation. In the MC analyses there were morphological alteration in enamel and dentin after the cumulative doses of 40 Gy. It was observed, by SEM, tags formations and alterations on the hybrid layer. It could be concluded that RT had affected the morphological surface of enamel and dentin, and that it affected the adhesion of the bonding systems, indicating that it should be waited at least 6 months after RT to perform restorative procedures, in which the Clearfil SE Bond was less affected
Adhesion of different adhesive systems to the enamel and dentin of primary teeth that have undergone radiotherapy
A radioterapia (RT), quando aplicada na região de cabeça e pescoço, pode ocasionar alterações estruturais no esmalte e na dentina que poderiam influenciar o comportamento dos sistemas adesivos. O presente estudo teve como objetivo avaliar a influência da RT na adesão dos sistemas adesivos (Clearfil SE Bond e Adper™ Single Bond 2) ao esmalte (E) e à dentina (D) de dentes decíduos, em diferentes tempos (antes e após a RT). Foram utilizados 60 molares decíduos seccionados obtendo um total de 120 fragmentos de esmalte e 120 de dentina que, após o preparo da superfície, foram divididos aleatoriamente em 4 grupos (n=30/grupo): G1 (controle) - esmalte/dentina sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT, G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo no subgrupo A empregado o sistema adesivo etch-rinse Adper™ Single Bond 2; e no subgrupo B o adesivo self-etch Clearfil SE Bond. Os espécimes foram irradiados com fração de dose de 2 Gy, por 5 dias consecutivos, até atingir a dose total de 60 Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentasse 4 mm de altura e 2 mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento (célula de carga 50 kgf e velocidade 0,5 mm/minuto) obtendo-se o resultado em N, o qual foi transformado em MPa. A análise do padrão de fratura foi realizada em microscopia confocal (MC). Foram selecionados 5 espécimes de esmalte e 5 espécimes de dentina, para realização da análise morfológica da superfície dental por meio de microscopia confocal, sendo estes avaliados a cada 10 Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para análise em microscopia eletrônica de varredura (MEV). O esmalte e a dentina foram analisados separadamente, sendo os dados analisados por ANOVA a 2 critérios e pós- teste de tukey (p0,05). O tipo de fratura predominante foi adesiva, que aumentou a predominância com a irradiação. Na análise em MC houve alterações morfológicas em esmalte e dentina após a dose cumulativa de 40 Gy. Em MEV observou-se a alterações na formação de tags e de camada híbrida. Pôde-se concluir que a radioterapia alterou a morfologia da superfície do esmalte e da dentina, e afetou a adesão dos sistemas adesivos, sendo necessário esperar pelo menos 6 meses para a realização dos procedimentos restauradores, tendo o sistema Clearfil SE Bond menos influenciado.When radiotherapy (RT) is performed in the head and neck region, it could lead to structural alteration in enamel and dentin that could influence the behavior of the bonding agents. The present study aimed to evaluate whether the RT interferes in the bonding o two adhesive systems (Clearfil SE Bond e AdperTM Single Bond 2) to enamel (E) and dentin (D) of primary teeth, in different times (before and after RT). Sixty primary molars were cut in a total of 120 fragments of enamel and 120 of dentin, which after the surface polishing were randomly divided into 4 groups (n=30/group): G1 (control) - enamel and dentin without RT + restorative procedures; G2 - restorative procedures performed before RT; G3 - restorative procedures performed after RT; and G4 - restorative procedures performed 6 months after RT. Each one of the groups was then divided into 2 subgroups: subgroup A using the etch-rinse Adper™ Single Bond 2; and subgroup B using the self-etch Clearfil SE Bond. The specimens were irradiated in dose fractions of 2 Gy, for 5 consecutive days, until reaching the final dose of 60Gy, in a total of 30 fractions, during 6 weeks. The restorative procedures were done using the Z350 composite, and for standardization of the restorations a matrix was used, so the specimens all presented 4 mm height and 2 mm of diameter. The specimens were submitted to the shear bond strength test (load of 50 kgf and speed of 0.5 mm/minute), the result was obtained in N and then transformed to Mpa. The fracture pattern was analyzed in a confocal microscopy (MC). Five specimens of enamel and 5 of dentin were chosen to the morphological analyzes also by MC, those specimens were evaluated every 10 Gy. As for the bonding interface 3 specimens of each group were chosen, and prepared for scanning electron microscopy (SEM). Enamel and dentin were evaluated separately, data was analyzed by the ANOVA and Post Test Tukey (p<0.05). Significance level was 5%. It could be observed that for both substrates the Clearfil SE Bond (E: 20.19 MPa; D: 17.61 MPa) was statically superior than Single Bond (E: 17.21 MPa; D: 15.45 MPa) (p<0.05). As for the time of restoration, group 2 had the worst results, in both enamel and dentin. It was observed that that radiation affected negatively the bonding in enamel and dentin (p<0.05), however, in the group 4 no alterations were observed (p<0.05). The predominant fracture pattern was the adhesive, which had raised its prevalence according to the radiation. In the MC analyses there were morphological alteration in enamel and dentin after the cumulative doses of 40 Gy. It was observed, by SEM, tags formations and alterations on the hybrid layer. It could be concluded that RT had affected the morphological surface of enamel and dentin, and that it affected the adhesion of the bonding systems, indicating that it should be waited at least 6 months after RT to perform restorative procedures, in which the Clearfil SE Bond was less affected
Influence of cobalto-60 irradiation on the mechanical, chemical and morphological properties of enamel and dentin of primary teeth an in vitro study
O objetivo do presente estudo foi avaliar, in vitro, os efeitos da irradiação com cobalto-60 (Co 60), nas propriedades do esmalte e da dentina de dentes decíduos por meio da: 1 - microdureza longitudinal; 2 - morfologia em microscopia eletrônica de varredura (MEV); e 3 - composição química em espectroscopia de energia dispersiva de raios X (EDX). No primeiro experimento foi avaliada a microdureza do esmalte e da dentina (n=12 hemissecções vestibulares) em 3 profundidade (superficial, média e profunda), antes e a cada 10 Gy de irradiação, até uma dose cumulativa total de 60 Gy. No segundo experimento foi avaliada a morfologia do esmalte e da dentina por meio de MEV (n=8 hemissecções), sendo 2 hemissecções vestibulares irradiadas com a dose cumulativa de 30 Gy, 2 hemissecções vestibulares irradiadas com a dose cumulativa de 60 Gy e 4 hemissecções palatinas não irradiadas. No terceiro experimento, identificou-se os elementos químicos do esmalte e da dentina por meio de EDX (n=4 hemissecções), utilizando-se as mesmas hemissecções previamente submetidas à MEV (com a dose cumulativa de 60 Gy de irradiação e nas hemissecções não irradiadas). No primeiro experimento a microdureza, antes e após, a irradiação, foi avaliada na mesma hemissecção dental (face vestibular). Já no segundo e terceiro experimentos, as hemissecções vestibulares foram submetidas à irradiação e as hemissecções palatinas do mesmo dente funcionaram como controle. Os dados foram analisados quanto à sua distribuição e submetidos à Análise de Variância a dois critérios. Para a diferenciação das médias, empregou-se o teste de Fisher. O nível de significância adotado foi de 5%. A microdureza longitudinal no esmalte, como um todo, variou após as diferentes doses de irradiação, aumentando significantemente após a dose de 60 Gy (p0,05). Observou-se que na dentina média foi encontrado o maior valor médio de microdureza (29,9 KH), o qual foi estatisticamente diferente (p0.05). The highest mean value of microhardness was obtained in the middle dentin (29.9 KH), which was significantly different (p<0.05) from the other analyzed regions. The morphological analysis of enamel and dentin revealed that the groups irradiated with doses of 30 Gy and 60 Gy presented greater surface alterations compared with non-irradiated specimens at all analyzed regions. The chemical analysis of irradiated enamel and dentin compared with non-irradiated specimens revealed a decrease of oxygen and an increase of calcium. In conclusion, irradiation of primary teeth with Co-60 influenced the longitudinal microhardness of enamel and dentin, according to the dose and irradiated region. In enamel as a whole, microhardness increased with the cumulative dose of 60 Gy, regardless of the analyzed region. In dentin, there was no change in the microhardness mean values after irradiation, regardless of the analyzed region. The analysis of morphology revealed that, the increase of the irradiation dose resulted in enamel and dentin disorganization, which presented an amorphous surface with difficulty in identifying enamel prisms and dentin tubules, respectively. The chemical analysis revealed a decrease in the percentage of oxygen and an increase in the percentage of calcium in irradiated enamel and dentin