9 research outputs found

    A Multicenter evaluation of safety of early extubation in liver transplant recipients

    No full text
    Small single-institutional studies performed prior to the introduction of organ allocation using the Model for End-Stage Liver Disease (MELD) suggest that early airway extubation of liver transplant recipients is a safe practice. We designed a multicenter study to examine adverse events associated with early extubation in patients selected for liver transplantation using MELD score. A total of 7 institutions extubated all patients meeting study criteria and reported adverse events that occurred within 72 hours following surgery. Adverse events were uncommon: occurring in only 7.7% of 391 patients studied. Most adverse events were pulmonary or surgically related. Pulmonary complications were usually minor, requiring only an increase in ambient oxygen concentration. The majority of surgical adverse events required additional surgery. Analysis of a limited set of perioperative variables suggest that blood transfusions and technical factors were associated with an increased risk of adverse events. In conclusion, while early extubation appears to be safe under specified circumstances, there are performance differences between institutions that remain to be explained

    Intraoperative ventilation: incidence and risk factors for receiving large tidal volumes during general anesthesia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is a growing concern of the potential injurious role of ventilatory over-distention in patients without lung injury. No formal guidelines exist for intraoperative ventilation settings, but the use of tidal volumes (V<sub>T</sub>) under 10 mL/kg predicted body weight (PBW) has been recommended in healthy patients. We explored the incidence and risk factors for receiving large tidal volumes (V<sub>T </sub>> 10 mL/kg PBW).</p> <p>Methods</p> <p>We performed a cross-sectional analysis of our prospectively collected perioperative electronic database for current intraoperative ventilation practices and risk factors for receiving large tidal volumes (V<sub>T </sub>> 10 mL/kg PBW). We included all adults undergoing prolonged (≥ 4 h) elective abdominal surgery and collected demographic, preoperative (comorbidities), intraoperative (i.e. ventilatory settings, fluid administration) and postoperative (outcomes) information. We compared patients receiving exhaled tidal volumes > 10 mL/kg PBW with those that received 8-10 or < 8 mL/kg PBW with univariate and logistic regression analyses.</p> <p>Results</p> <p>Ventilatory settings were non-uniform in the 429 adults included in the analysis. 17.5% of all patients received V<sub>T </sub>> 10 mL/kg PBW. 34.0% of all obese patients (body mass index, BMI, ≥ 30), 51% of all patients with a height < 165 cm, and 34.6% of all female patients received V<sub>T </sub>> 10 mL/kg PBW.</p> <p>Conclusions</p> <p>Ventilation with V<sub>T </sub>> 10 mL/kg PBW is still common, although poor correlation with PBW suggests it may be unintentional. BMI ≥ 30, female gender and height < 165 cm may predispose to receive large tidal volumes during general anesthesia. Further awareness of patients' height and PBW is needed to improve intraoperative ventilation practices. The impact on clinical outcome needs confirmation.</p

    Validating the Edinburgh Postnatal Depression Scale as a screening tool for postpartum depression in Kathmandu, Nepal.

    Get PDF
    Background: Edinburgh Postnatal Depression Scale (EPDS) is considered well accepted screening tool for postpartum depression (PPD). The objective of the study was to validate the EPDS as a screening tool for postpartum depression in Kathmandu, Nepal. Methods: A hospital based cross sectional study using EPDS was conducted among 346 mothers between 4 and 14 weeks of postpartum period. All the participants were examined by psychiatrist for possible clinical PPD diagnosis using International Classification of Disease tenth revision (ICD-10). Sensitivity, specificity, positive predictive value and negative predictive value were calculated for validation of EPDS. The best cut off point for Nepalese version of EPDS was identified and area of the receiver operating characteristics curve was calculated. Results: The overall prevalence of PPD was 17.1 %.The sensitivity, specificity, positive predictive value and negative predictive value of the Nepalese version EPDS was found to be 92, 95.6, 77 and 99.3 % respectively. The best cut-off point of EPDS for screening of PPD was found to be 12/13 and the area of the curve was 0.98 (95 % CI 0.970–0.994, p = 0.001). Conclusions: The prevalence of PPD is not that far from the previous studies of Nepal. Nepali version of EPDS was acceptable and the study demonstrates good validity, thus EPDS can be used as valid screening tool for PPD for early detection, prompt treatment and to prevent possible consequences
    corecore