1,554 research outputs found
Effect of Pancuronium on Plasma Free-Norepinephrine and Epinephrine in Adult Cardiac Surgical Patients
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65996/1/j.1399-6576.1978.tb01318.x.pd
Experimental study of 199Hg spin anti-relaxation coatings
We report on a comparison of spin relaxation rates in a Hg
magnetometer using different wall coatings. A compact mercury magnetometer was
built for this purpose. Glass cells coated with fluorinated materials show
longer spin coherence times than if coated with their hydrogenated homologues.
The longest spin relaxation time of the mercury vapor was measured with a
fluorinated paraffin wall coating.Comment: 9 pages, 6 figures, submitted to JINS
ARTERIAL BLOOD GASES AFTER ATROPINE SULPHATE IN HEALTHY VOLUNTEERS
The effects of atropine 0.6 mg. intravenously administered to ten healthy volunteers in recumbent position, on arterial pH, PaCO2, and PaO2 were determined; there were no significant alterations of blood gas values after atropine administration. There seems to be no contraindication to the use of atropine sulphate for premedication in terms of its effect upon arterial blood-gases, in patients with normal cardiorespiratory function.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/32885/1/0000263.pd
Comparison of ultracold neutron sources for fundamental physics measurements
Ultracold neutrons (UCNs) are key for precision studies of fundamental
parameters of the neutron and in searches for new CP violating processes or
exotic interactions beyond the Standard Model of particle physics. The most
prominent example is the search for a permanent electric dipole moment of the
neutron (nEDM). We have performed an experimental comparison of the leading UCN
sources currently operating. We have used a 'standard' UCN storage bottle with
a volume of 32 liters, comparable in size to nEDM experiments, which allows us
to compare the UCN density available at a given beam port.Comment: 20 pages, 30 Figure
A gyermek 2 (1908) 07
A gyermek
A Magyar Gyermektanulmányi Társaság közlönye
2. évfolyam, 07. szám
Budapest, 1908. szeptember
A folyóirat 1908-ig a Gyermekvédelmi lap mellékleteként, 1909-től mint önálló lap jelent meg
A highly stable atomic vector magnetometer based on free spin precession
We present a magnetometer based on optically pumped Cs atoms that measures
the magnitude and direction of a 1 T magnetic field. Multiple circularly
polarized laser beams were used to probe the free spin precession of the Cs
atoms. The design was optimized for long-time stability and achieves a scalar
resolution better than 300 fT for integration times ranging from 80 ms to 1000
s. The best scalar resolution of less than 80 fT was reached with integration
times of 1.6 to 6 s. We were able to measure the magnetic field direction with
a resolution better than 10 rad for integration times from 10 s up to 2000
s
Constraining interactions mediated by axion-like particles with ultracold neutrons
We report a new limit on a possible short range spin-dependent interaction
from the precise measurement of the ratio of Larmor precession frequencies of
stored ultracold neutrons and Hg atoms confined in the same volume. The
measurement was performed in a 1 T vertical magnetic holding field
with the apparatus searching for a permanent electric dipole moment of the
neutron at the Paul Scherrer Institute. A possible coupling between freely
precessing polarized neutron spins and unpolarized nucleons of the wall
material can be investigated by searching for a tiny change of the precession
frequencies of neutron and mercury spins. Such a frequency change can be
interpreted as a consequence of a short range spin-dependent interaction that
could possibly be mediated by axions or axion-like particles. The interaction
strength is proportional to the CP violating product of scalar and pseudoscalar
coupling constants . Our result confirms limits from complementary
experiments with spin-polarized nuclei in a model-independent way. Limits from
other neutron experiments are improved by up to two orders of magnitude in the
interaction range of m
An Improved Neutron Electric Dipole Moment Experiment
A new measurement of the neutron EDM, using Ramsey's method of separated
oscillatory fields, is in preparation at the new high intensity source of
ultra-cold neutrons (UCN) at the Paul Scherrer Institute, Villigen, Switzerland
(PSI). The existence of a non-zero nEDM would violate both parity and time
reversal symmetry and, given the CPT theorem, might lead to a discovery of new
CP violating mechanisms. Already the current upper limit for the nEDM
(|d_n|<2.9E-26 e.cm) constrains some extensions of the Standard Model.
The new experiment aims at a two orders of magnitude reduction of the
experimental uncertainty, to be achieved mainly by (1) the higher UCN flux
provided by the new PSI source, (2) better magnetic field control with improved
magnetometry and (3) a double chamber configuration with opposite electric
field directions.
The first stage of the experiment will use an upgrade of the RAL/Sussex/ILL
group's apparatus (which has produced the current best result) moved from
Institut Laue-Langevin to PSI. The final accuracy will be achieved in a further
step with a new spectrometer, presently in the design phase.Comment: Flavor Physics & CP Violation Conference, Taipei, 200
Solid deuterium surface degradation at ultracold neutron sources
Solid deuterium (sD_2) is used as an efficient converter to produce ultracold
neutrons (UCN). It is known that the sD_2 must be sufficiently cold, of high
purity and mostly in its ortho-state in order to guarantee long lifetimes of
UCN in the solid from which they are extracted into vacuum. Also the UCN
transparency of the bulk sD_2 material must be high because crystal
inhomogeneities limit the mean free path for elastic scattering and reduce the
extraction efficiency. Observations at the UCN sources at Paul Scherrer
Institute and at Los Alamos National Laboratory consistently show a decrease of
the UCN yield with time of operation after initial preparation or later
treatment (`conditioning') of the sD_2. We show that, in addition to the
quality of the bulk sD_2, the quality of its surface is essential. Our
observations and simulations support the view that the surface is deteriorating
due to a build-up of D_2 frost-layers under pulsed operation which leads to
strong albedo reflections of UCN and subsequent loss. We report results of UCN
yield measurements, temperature and pressure behavior of deuterium during
source operation and conditioning, and UCN transport simulations. This,
together with optical observations of sD_2 frost formation on initially
transparent sD_2 in offline studies with pulsed heat input at the North
Carolina State University UCN source results in a consistent description of the
UCN yield decrease.Comment: 15 pages, 22 figures, accepted by EPJ-
An Improved Search for the Neutron Electric Dipole Moment
A permanent electric dipole moment of fundamental spin-1/2 particles violates
both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity
(CP) symmetry since there is no sign of CPT-violation. The search for a neutron
electric dipole moment (nEDM) probes CP violation within and beyond the Stan-
dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an
improved, upgraded version of the apparatus which provided the current best
experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL
collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next
two years we aim to improve the sensitivity of the apparatus to sigma(dn) =
2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in
case for a null result. In parallel the collaboration works on the design of a
new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.Comment: APS Division for particles and fields, Conference Proceedings, Two
figure
- …