62 research outputs found

    Secondary breast lymphoma diagnosed by vacuum-assisted breast biopsy: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Breast lymphoma, either as a manifestation of primary extranodal disease or as secondary involvement, is a rare malignancy, and its diagnosis, prognosis, and treatment have not been clearly defined. On the other hand, Vacuum-assisted breast biopsy (VABB) is a minimally invasive technique with ever-growing use for the diagnosis of mammographically detected, non-palpable breast lesions.</p> <p>Case presentation</p> <p>A symptom-free, 56-year-old woman presented with a non-palpable BI-RADS 4B lesion without microcalcifications. She had a positive family history for breast cancer and a history of atypical ductal hyperplasia in the ipsilateral breast four years ago. She reported having been treated for non-Hodgkin lymphoma 12 years ago. With the suspicion of breast cancer, mammographically guided VABB with 11-gauge probe (on the stereotactic Fisher's table) was performed. VABB made the diagnosis of a non-Hodgkin, grade II, B-cell germinal-center lymphoma. VABB yielded enough tissue for immunohistochemistry/WHO classification.</p> <p>Conclusion</p> <p>This is the first case in the literature demonstrating the successful diagnosis of breast lymphoma by VABB, irrespectively of the level of clinical suspicion. It should be stressed that VABB was able to yield enough tissue for WHO classification. In general, lymphoma should never be omitted in the differential diagnosis, since no pathognomonic radiologic findings exist for its diagnosis.</p

    Microvascular blood flow response in the intestinal wall and the omentum during negative wound pressure therapy of the open abdomen

    Get PDF
    PURPOSE: Higher closure rates of the open abdomen have been reported with negative pressure wound therapy (NPWT) compared with other wound therapy techniques. However, the method has occasionally been associated with increased development of intestinal fistulae. The present study measures microvascular blood flow in the intestinal wall and the omentum before and during NPWT. METHODS: Six pigs underwent midline incision and application of NPWT to the open abdomen. The microvascular blood flow in the underlying intestinal loop wall and the omentum was recorded before and after the application of NPWT of -50, -70, -100, -120, -150, and -170 mmHg respectively, using laser Doppler velocimetry. RESULTS: A significant decrease in microvascular blood flow was seen in the intestinal wall during application of all negative pressures levels. The blood flow was 2.7 (±0.2) Perfusion Units (PU) before and 2.0 (±0.2) PU (*p < 0.05) after application of -50 mmHg, and 3.6 (±0.6) PU before and 1.5 (±0.2) PU (**p < 0.01) after application of -170 mmHg. CONCLUSIONS: In the present study, we show that negative pressures between -50 and -170 mmHg induce a significant decrease in the microvascular blood flow in the intestinal wall. The decrease in blood flow increased with the amount of negative pressure applied. One can only speculate that a longstanding decreased blood flow in the intestinal wall may induce ischemia and secondary necrosis in the intestinal wall, which, theoretically, could promote the development of intestinal fistulae. We believe that NPWT of the open abdomen is a very effective treatment but could probably be improved

    No hypoperfusion is produced in the epicardium during application of myocardial topical negative pressure in a porcine model

    Get PDF
    ABSTRACT: BACKGROUND: Topical negative pressure (TNP), commonly used in wound therapy, has been shown to increase blood flow and stimulate angiogenesis in skeletal muscle. We have previously shown that a myocardial TNP of -50 mmHg significantly increases microvascular blood flow in the myocardium. When TPN is used in wound therapy (on skeletal and subcutaneous tissue) a zone of relative hypoperfusion is seen close to the wound edge. Hypoperfusion induced by TNP is thought to depend on tissue density, distance from the negative pressure source, and the amount negative pressure applied. When applying TNP to the myocardium, a significant, long-standing zone of hypoperfusion could theoretically cause ischemia, and negative effects on the myocardium. The current study was designed to elucidate whether hypoperfusion was produced during myocardial TNP. METHODS: Six pigs underwent median sternotomy. Laser Doppler probes were inserted horizontally into the heart muscle in the LAD area, at depths of approximately, 1-2 mm. The microvascular blood flow was measured before and after the application of a TNP. Analyses were performed before left anterior descending artery (LAD) occlusion (normal myocardium) and after 20 minutes of LAD occlusion (ischemic myocardium). RESULTS: A TNP of -50 mmHg induced a significant increase in microvascular blood flow in normal myocardium (**p = 0.01), while -125 mmHg did not significantly alter the microvascular blood flow. In ischemic myocardium a TNP of -50 mmHg induced a significant increase in microvascular blood flow (*p = 0.04), while -125 mmHg did not significantly alter the microvascular blood flow. CONCLUSION: No hypoperfusion could be observed in the epicardium in neither normal nor ischemic myocardium during myocardial TNP

    A compare between myocardial topical negative pressure levels of -25 mmHg and -50 mmHg in a porcine model

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Topical negative pressure (TNP), widely used in wound therapy, is known to stimulate wound edge blood flow, granulation tissue formation, angiogenesis, and revascularization. We have previously shown that application of a TNP of -50 mmHg to the myocardium significantly increases microvascular blood flow in the underlying tissue. We have also shown that a myocardial TNP levels between -75 mmHg and -150 mmHg do not induce microvascular blood flow changes in the underlying myocardium. The present study was designed to elucidate the difference between -25 mmHg and -50 mmHg TNP on microvascular flow in normal and ischemic myocardium.</p> <p>Methods</p> <p>Six pigs underwent median sternotomy. The microvascular blood flow in the myocardium was recorded before and after the application of TNP using laser Doppler flowmetry. Analyses were performed before left anterior descending artery (LAD) occlusion (normal myocardium), and after 20 minutes of LAD occlusion (ischemic myocardium).</p> <p>Results</p> <p>A TNP of -25 mmHg significantly increased microvascular blood flow in both normal (from 263.3 ± 62.8 PU before, to 380.0 ± 80.6 PU after TNP application, * <it>p </it>= 0.03) and ischemic myocardium (from 58.8 ± 17.7 PU before, to 85.8 ± 20.9 PU after TNP application, * <it>p </it>= 0.04). A TNP of -50 mmHg also significantly increased microvascular blood flow in both normal (from 174.2 ± 20.8 PU before, to 240.0 ± 34.4 PU after TNP application, * <it>p </it>= 0.02) and ischemic myocardium (from 44.5 ± 14.0 PU before, to 106.2 ± 26.6 PU after TNP application, ** <it>p </it>= 0.01).</p> <p>Conclusion</p> <p>Topical negative pressure of -25 mmHg and -50 mmHg both induced a significant increase in microvascular blood flow in normal and in ischemic myocardium. The increase in microvascular blood flow was larger when using -25 mmHg on normal myocardium, and was larger when using -50 mmHg on ischemic myocardium; however these differences were not statistically significant.</p

    Population attributable fractions for ovarian cancer in Swedish women by morphological type

    Get PDF
    Using the Swedish Family-Cancer Database, among a total of 1 030 806 women followed from 1993 through 2004, invasive and borderline epithelial ovarian cancer was identified in 3306 and 822 women respectively, with data on family history, reproductive variables, residential region and socioeconomic status. Relative risks and population-attributable fractions (PAFs) were estimated by Poisson regression. The overall PAFs of invasive epithelial ovarian cancer for family history and for reproductive factors were 2.6 and 22.3%, respectively, for serous/seropapillary cystadenocarcinoma (3.0 and 19.1%), endometrioid carcinoma (2.6 and 26.6%), mucinous cystadenocarcinoma (0.5 and 23.9%) and clear-cell carcinoma (2.6 and 73.9%). The corresponding PAFs of borderline tumours due to family history were lower, but higher due to reproductive factors. Family history, low parity and young age at first birth were associated with elevated risks. The risks for women with a family history were among the highest, but these women accounted for the smallest proportion of the cases, giving the lowest PAFs

    Theoretical study of Oldroyd-b visco-elastic fluid flow through curved pipes with slip effects in polymer flow processing

    Get PDF
    The characteristics of the flow field of both viscous and viscoelastic fluids passing through a curved pipe with a Navier slip boundary condition have been investigated analytically in the present study. The Oldroyd-B constitutive equation is employed to simulate realistic transport of dilute polymeric solutions in curved channels. In order to linearize the momentum and constitutive equations, a perturbation method is used in which the ratio of radius of cross section to the radius of channel curvature is employed as the perturbation parameter. The intensity of secondary and main flows is mainly affected by the hoop stress and it is demonstrated in the present study that both the Weissenberg number (the ratio of elastic force to viscous force) and slip coefficient play major roles in determining the strengths of both flows. It is also shown that as a result of an increment in slip coefficient, the position of maximum velocity markedly migrates away from the pipe center towards the outer side of curvature. Furthermore, results corresponding to Navier slip scenarios exhibit non-uniform distributions in both the main and lateral components of velocity near the wall which can notably vary from the inner side of curvature to the outer side. The present solution is also important in polymeric flow processing systems because of experimental evidence indicating that the no-slip condition can fail for these flows, which is of relevance to chemical engineers

    Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach.</p> <p>Methods</p> <p>A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009.</p> <p>Results</p> <p>Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for a benign finding seen on the original ultrasound-guided diagnostic breast biopsy procedure.</p> <p>Conclusions</p> <p>In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information.</p
    corecore