5 research outputs found

    Legionellosis Agent Indication Using Immunochromatography with Visual and Digital Video Detection

    No full text
    Proposed was the immunochromatographic express-test for legionellosis agent detection in water environment. The method is high-sensitive and specific allowing to detect only first serogroup of legionellosis agent. That is of high importance for identification of isolated cultures of legionella and monitoring of Legionella pneumophila presence in environment objects

    Assessment of Diagnostic Specificity of Anti-SARS-CoV-2 Antibody Tests and Their Application for Monitoring of Seroconversion and Stability of Antiviral Antibody Response in Healthcare Workers in Moscow

    No full text
    Anti-SARS-CoV-2 antibody testing is an efficient tool to assess the proportion of seropositive population due to infection and/or vaccination. Numerous test systems utilizing various antigen composition(s) are routinely used for detection and quantitation of anti-SARS-CoV-2 antibodies. We determined their diagnostic specificity using archived true-negative samples collected before the onset of the COVID-19 pandemic. Using test systems demonstrating 98.5–100% specificity, we assessed the dynamics of SARS-CoV-2 seroconversion and durability of anti-spike (S) antibodies in healthcare professionals (n = 100) working in Moscow during the first two cycles of the pandemic (May 2020 to June 2021) outside of the “red zone”. Analysis revealed a rapid increase in anti-SARS-CoV-2 seropositivity from 19 to 80% (19/100 and 80/100, respectively) due to virus exposition/infection; only 16.3% of seroconversion cases (13/80) were due to vaccination, but not the virus exposure, although massive COVID-19 vaccination of healthcare workers was performed beginning in December 2020. In total, 12.7% (8/63) remained positive for anti-SARS-CoV-2 IgM for >6 months, indicating unsuitability of IgM for identification of newly infected individuals. All except one remained seropositive for anti-S antibodies for >9 months on average. Significant (>15%) declines in anti-SARS-CoV-2 antibody concentrations were observed in only 18% of individuals (9/50). Our data on the high seropositivity rate and stability of anti-SARS-CoV-2 antibody levels in healthcare personnel working outside of the “red zone” indicate their regular exposition to SARS-CoV-2/an increased risk of infection, while a low frequency of vaccine-induced antibody response acquired after the start of vaccination points to vaccine hesitancy. © 2022 by the authors. Licensee MDPI, Basel, Switzerland
    corecore