24 research outputs found

    Use of intraventricular ribbon gauze to reduce particulate emboli during aortic valve replacement

    Get PDF
    BACKGROUND: The incidence of cerebrovascular accidents following aortic valve surgery remains a devastating complication. The aim of this study was to determine the number of potential embolic material arising during aortic valve replacement and to examine the efficacy of using ribbon gauze in the left ventricle during removal of the native valve and decalcification of the aortic annulus. METHODS: Ribbon gauze was inserted into the left ventricular cavity prior to aortic valve excision in an unselected, prospectively studied series of 30 patients undergoing aortic valve replacement. A further 30 lengths of ribbon gauze were soaked in the pericardiotomy blood of the same patients and all were subjected to histological analysis. RESULTS: The median number of tissue fragments from the aortic valve replacement group was significantly higher than in the control group 5 (0–18) versus 0 (0–1) (p = 3.6 × 10(-5)). The size of tissue fragments varied between 0.1 and 9.0 mm with a mean of 0.61 ± 1.12 mm and a median of 0.2 mm. There was a significantly higher number of tissue fragments associated with patients having surgery for aortic stenosis when compared with patients who had aortic regurgitation with median of 5 (0–18) versus 0 (0–3) (p = 0.8 × 10(-3)). CONCLUSION: Significant capture of particulate debris by the intraventricular ribbon gauze suggests that the technique of left ventricular ribbon gauze insertion during aortic valve excision has merit

    HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations

    Get PDF
    The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    Get PDF
    OBJECTIVES: A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS: The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months contin

    2019 EACTS Expert Consensus on long-term mechanical circulatory support

    Get PDF
    Long-term mechanical circulatory support (LT-MCS) is an important treatment modality for patients with severe heart failure. Different devices are available, and many-sometimes contradictory-observations regarding patient selection, surgical techniques, perioperative management and follow-up have been published. With the growing expertise in this field, the European Association for Cardio-Thoracic Surgery (EACTS) recognized a need for a structured multidisciplinary consensus about the approach to patients with LT-MCS. However, the evidence published so far is insufficient to allow for generation of meaningful guidelines complying with EACTS requirements. Instead, the EACTS presents an expert opinion in the LT-MCS field. This expert opinion addresses patient evaluation and preoperative optimization as well as management of cardiac and non-cardiac comorbidities. Further, extensive operative implantation techniques are summarized and evaluated by leading experts, depending on both patient characteristics and device selection. The faculty recognized that postoperative management is multidisciplinary and includes aspects of intensive care unit stay, rehabilitation, ambulatory care, myocardial recovery and end-of-life care and mirrored this fact in this paper. Additionally, the opinions of experts on diagnosis and management of adverse events including bleeding, cerebrovascular accidents and device malfunction are presented. In this expert consensus, the evidence for the complete management from patient selection to end-of-life care is carefully reviewed with the aim of guiding clinicians in optimizing management of patients considered for or supported by an LT-MCS device

    Heartmate 3 fully magnetically levitated left ventricular assist device for the treatment of advanced heart failure –1 year results from the Ce mark trial

    No full text
    Abstract Background The HeartMate 3 Left Ventricular Assist System (LVAS) (St. Jude Medical Inc., St Paul, MN) with full magnetic levitation allows for wide and consistent blood flow paths and an artificial pulse designed for enhanced hemocompatibility. The HeartMate 3 received market approval in the European Union in 2015 following completion of a multicenter study. After reaching the 6-month study endpoint, patients continue to be followed for 2 years with the 1-year results presented herein. Methods A prospective, non-randomized study included adults with advanced heart failure and ejection fraction (EF) ≤ 25%, cardiac index (CI) ≤ 2.2 L/min/m2 while not on inotropes, or inotrope dependent, or on optimal medical management for 45/60 days. Results Fifty patients—54% bridge to transplant (BTT) and 46% destination therapy (DT)—were enrolled and implanted with the HeartMate 3. At baseline, 92% of the patients were INTERMACS profiles 2–4, with cardiac index 1.8 + 0.5 L/min/m2 and 58% were supported with inotropes. At 1 year, 74% of the patients remain on support, 18% expired, 6% transplanted, and 2% explanted. The adverse events include 12% gastrointestinal bleeding, 16% driveline infections, 18% strokes, and 2% outflow graft thrombosis. There was no hemolysis, pump thrombosis or pump malfunction through 1 year. The six-minute walk test distance increased from a mean of 273 m to 371 m (P <0.0001). EQ-5D quality-of-life score increased from a mean of 52.7 to 70.8 (P = 0.0006). Conclusions The 1-year HeartMate 3 LVAS results show survival and adverse-event profile are similar to other approved devices, with no pump thrombosis or pump failure. Patient’s functional status and quality of life significantly improved over time. Trial registration Clinicaltrials.gov registration number: NCT02170363 . Registered June 19, 2014